The DOI matches its Crossref record.
Dose and image quality for a cone‐beam C‐arm CT system
Abstract
We assess dose and image quality of a state‐of‐the‐art angiographic C‐arm system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) for three‐dimensional neuro‐imaging at various dose levels and tube voltages and an associated measurement method. Unlike conventional CT, the beam length covers the entire phantom, hence, the concept of computed tomography dose index (CTDI) is not the metric of choice, and one can revert to conventional dosimetry methods by directly measuring the dose at various points using a small ion chamber. This method allows us to define and compute a new dose metric that is appropriate for a direct comparison with the familiar of conventional CT. A perception study involving the CATPHAN 600 indicates that one can expect to see at least the inset with 0.5% nominal contrast at the recommended head‐scan dose when using tube voltages ranging from to . When analyzing the impact of tube voltage on image quality at a fixed dose, we found that lower tube voltages gave improved low contrast detectability for small‐diameter objects. The relationships between kVp, image noise, dose, and contrast perception are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
Ludlow, J. B., & Ivanovic, M. (2008) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2008.03.018 · Cited by 872
Conebeam CT of the Head and Neck, Part 1: Physical Principles
Miracle, A. C., & Mukherji, S. K. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1653 · Cited by 387
Flat-detector computed tomography (FD-CT)
Kalender, W. A., & Kyriakou, Y. (2007) · European Radiology · doi:10.1007/s00330-007-0651-9 · Cited by 302
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Metadata
- Authors
- Fahrig, R., Dixon, R., Payne, T., Morin, R. L., Ganguly, A., & Strobel, N.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2006-11-16
- Volume
- 33
- Issue
- 12
- Pages
- 4541-4550
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2042852309
- Cited by
- 176
- References
- 0
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dose and image quality for a cone‐beam C‐arm CT system. https://app.cochat.ai/papers/10.1118/1.2370508
- The paper
- Fahrig, R., Dixon, R., Payne, T., Morin, R. L., Ganguly, A., & Strobel, N. (2006). Dose and image quality for a cone‐beam C‐arm CT system. Medical Physics. https://doi.org/10.1118/1.2370508
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.