Respiratory gating in positron emission tomography: A quantitative comparison of different gating schemes
Abstract
Respiratory gating is used for reducing the effects of breathing motion in a wide range of applications from radiotherapy treatment to diagnostical imaging. Different methods are feasible for respiratory gating. In this study seven gating methods were developed and tested on positron emission tomography (PET) listmode data. The results of seven patient studies were compared quantitatively with respect to motion and noise. (1) Equal and (2) variable time‐based gating methods use only the time information of the breathing cycle to define respiratory gates. (3) Equal and (4) variable amplitude‐based gating approaches utilize the amplitude of the respiratory signal. (5) Cycle‐based amplitude gating is a combination of time and amplitude‐based techniques. A baseline correction was applied to methods (3) and (4) resulting in two new approaches: Baseline corrected (6) equal and (7) variable amplitude‐based gating. Listmode PET data from seven patients were acquired together with a respiratory signal. Images were reconstructed applying the seven gating methods. Two parameters were used to quantify the results: Motion was measured as the displacement of the heart due to respiration and noise was defined as the standard deviation of pixel intensities in a background region. The amplitude‐based approaches (3) and (4) were superior to the time‐based methods (1) and (2). The improvement in capturing the motion was more than 30% (up to 130%) in all subjects. The variable time (2) and amplitude (4) methods had a more uniform noise distribution among all respiratory gates compared to equal time (1) and amplitude (3) methods. Baseline correction did not improve the results. Out of seven different respiratory gating approaches, the variable amplitude method (4) captures the respiratory motion best while keeping a constant noise level among all respiratory phases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Cited by
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Dual-Modality Imaging: Combining Anatomy and Function
Townsend, D. W. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051276 · Cited by 282
PET in the management of locally advanced and metastatic NSCLC
Grootjans, W., de Geus-Oei, L.-F., Troost, E. G. C., Visser, E. P., Oyen, W. J. G., & Bussink, J. (2015) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2015.75 · Cited by 97
Grootjans, W., de Geus-Oei, L.-F., Meeuwis, A. P. W., van der Vos, C. S., Gotthardt, M., Oyen, W. J. G., & Visser, E. P. (2014) · European Radiology · doi:10.1007/s00330-014-3362-z · Cited by 57
Enhancing Cardiac PET by Motion Correction Techniques
Rubeaux, M., Doris, M. K., Alessio, A., & Slomka, P. J. (2017) · Current Cardiology Reports · doi:10.1007/s11886-017-0825-2 · Cited by 48
Metadata
- Authors
- Dawood, M., Büther, F., Lang, N., Schober, O., & Schäfers, K. P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2007-06-27
- Volume
- 34
- Issue
- 7
- Pages
- 3067-3076
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1978063497
- Cited by
- 211
- References
- 1
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory gating in positron emission tomography: A quantitative comparison of different gating schemes. https://app.cochat.ai/papers/10.1118/1.2748104
- The paper
- Dawood, M., Büther, F., Lang, N., Schober, O., & Schäfers, K. P. (2007). Respiratory gating in positron emission tomography: A quantitative comparison of different gating schemes. Medical Physics. https://doi.org/10.1118/1.2748104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.