Enhancing Cardiac PET by Motion Correction Techniques
Abstract
Purpose of review Cardiac positron emission tomography (PET) images often contain errors due to cardiac, respiratory, and patient motion during relatively long image acquisition. Advanced motion compensation techniques may improve PET spatial resolution, eliminate potential artifacts, and ultimately improve the research and clinical capabilities of PET. Recent findings Combined cardiac and respiratory gating has only recently been implemented in clinical PET systems. Considering that the gated image bins contain much lower counts than the original PET data, they need to be summed after correcting for motion, forming motion-corrected, high-count image volume. Furthermore, automated image registration techniques can be used to correct for motion between CT attenuation scan and PET acquisition. While motion correction methods are not yet widely used in clinical practice, approaches including dual-gated non-rigid motion correction and the incorporation of motion correction information into the reconstruction process have the potential to markedly improve cardiac PET imaging.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In cardiac PET imaging, contraction of the myocardium contributes to quantitative inaccuracy of uncorrected static PET protocols.
“In cardiac PET imaging, contraction of the myocardium further contributes to the quantitative inaccuracy of uncorrected static PET protocols [90,91].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [91]
Cites
Joshi, N. V., Vesey, A. T., Williams, M. C., Shah, A. S. V., Calvert, P. A., Craighead, F., Yeoh, S. E., Wallace, W. A., Salter, D. M., Fletcher, A. M., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(13)61754-7 · Cited by 953 · see citing works
Tawakol, A. A., Migrino, R. Q., Bashian, G. G., Bedri, S. A., Vermylen, D., Cury, R. C., Yates, D. P., LaMuraglia, G. M., Furie, K. L., Houser, S. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.076 · Cited by 915 · see citing works
Simvastatin Attenuates Plaque Inflammation
Tahara, N., Kai, H., Ishibashi, M., Nakaura, H., Kaida, H., Baba, K., Hayabuchi, N., & Imaizumi, T. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.069 · Cited by 649 · see citing works
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 625 · see citing works
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536 · see citing works
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515 · see citing works
Physical and clinical performance of the mCT time-of-flight PET/CT scanner
Jakoby, B., Bercier, Y., Conti, M., Casey, M. E., Bendriem, B., & Townsend, D. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/8/004 · Cited by 487 · see citing works
Low, D. A., Nystrom, M. M., Kalinin, E., Parikh, P. J., Dempsey, J. F., Bradley, J. D., Mutic, S., Wahab, S. H., Islam, T., Christensen, G. E., et al. (2003) · Medical Physics · doi:10.1118/1.1576230 · Cited by 476 · see citing works
Acquiring 4D thoracic CT scans using a multislice helical method
Keall, P., Starkschall, G., Shukla, H., Forster, K. M., Ortiz, V. P., Stevens, C. W., Vedam, S. S., George, R., Guerrero, T. M., & Mohan, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/10/015 · Cited by 399 · see citing works
Symmetric Log-Domain Diffeomorphic Registration: A Demons-Based Approach
Vercauteren, T. K., Pennec, X., Aymeric Perchant, B., & Ayache, N. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85988-8_90 · Cited by 356 · see citing works
Respiratory Motion in Positron Emission Tomography/Computed Tomography: A Review
Nehmeh, S. A., & Erdi, Y. E. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.002 · Cited by 318 · see citing works
Gould, K. L., Pan, T., Loghin, C., Johnson, N. P., Guha, A., & Sdringola, S. M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.039792 · Cited by 292 · see citing works
Clinical Myocardial Perfusion PET/CT
Carli, M. F. D., Dorbala, S., Meserve, J. D., Fakhri, G. E., Sitek, A., & Moore, S. C. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032789 · Cited by 289 · see citing works
Tawakol, A. A., Migrino, R. Q., Hoffmann, U., Abbara, S., Houser, S. L., Gewirtz, H., Muller, J. E., Brady, T. J., & Fischman, A. J. (2005) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2005.03.002 · Cited by 278 · see citing works
Lamare, F., Ledesma‐Carbayo, M. J., Cresson, T., Kontaxakis, G., Santos, A., Rest, C. C. L., Reader, A. J., & Visvikis, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/17/006 · Cited by 259 · see citing works
Attenuation correction of PET images with respiration-averaged CT images in PET/CT.
Pan, T., Mawlawi, O. R., Nehmeh, S. A., Erdi, Y. E., Luo, D., Liu, H. H., Castillo, R., Mohan, R., Liao, Z. X., & Macapinlac, H. A. (2005) · PubMed · Cited by 251 · see citing works
A motion-incorporated reconstruction method for gated PET studies
Qiao, F., Pan, T., Clark, J. W., & Mawlawi, O. R. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/012 · Cited by 239 · see citing works
Quantitation of respiratory motion during 4D‐PET/CT acquisition
Nehmeh, S. A., Erdi, Y. E., Pan, T.-S., Yorke, E. D., Mageras, G. S., Rosenzweig, K., Schöder, H. M., Mostafavi, H., Squire, O. D., Pevsner, A., et al. (2004) · Medical Physics · doi:10.1118/1.1739671 · Cited by 232 · see citing works
Dawood, M., Büther, F., Lang, N., Schober, O., & Schäfers, K. P. (2007) · Medical Physics · doi:10.1118/1.2748104 · Cited by 211 · see citing works
List Mode–Driven Cardiac and Respiratory Gating in PET
Büther, F., Dawood, M., Stegger, L., Wübbeling, F., Schäfers, M. A., Schober, O., & Schäfers, K. P. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.059204 · Cited by 205 · see citing works
Image registration via level-set motion: Applications to atlas-based segmentation
Vemuri, B. C., Ye, J., Chen, Y., & Leonard, C. M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00063-4 · Cited by 203 · see citing works
Respiration-induced Attenuation Artifact at PET/CT: Technical Considerations
Goerres, G. W., Burger, C., Kamel, E. M., Seifert, B., Kaim, A. H., Buck, A., Buehler, T. C., & von Schulthess, G. K. (2003) · Radiology · doi:10.1148/radiol.2263011732 · Cited by 198 · see citing works
Li, X. A., Stepaniak, C., & Gore, E. (2005) · Medical Physics · doi:10.1118/1.2147743 · Cited by 187 · see citing works
Displacement and velocity of the coronary arteries: cardiac and respiratory motion
Shechter, G., Resar, J. R., & McVeigh, E. R. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862752 · Cited by 164 · see citing works
Physical Principles and Technology of Clinical PET Imaging
Dw, T. (2004) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v33n2p133 · Cited by 154 · see citing works
Motion Correction in Dual Gated Cardiac PET Using Mass-Preserving Image Registration
Gigengack, F., Ruthotto, L., Burger, M., Wolters, C. H., Jiang, X., & Schäfers, K. P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2175402 · Cited by 138 · see citing works
Livieratos, L., Stegger, L., Bloomfield, P. M., Schäfers, K. P., Bailey, D. L., & Camici, P. G. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/14/008 · Cited by 138 · see citing works
Dual cardiac–respiratory gated PET: implementation and results from a feasibility study
Martínez-Möller, A., Zikic, D., Botnar, R. M., Bundschuh, R. A., Howe, W., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0374-9 · Cited by 131 · see citing works
Cheng, V., Slomka, P. J., Ahlen, M., Thomson, L., Waxman, A. D., & Berman, D. S. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-009-9179-5 · Cited by 118 · see citing works
Self-citationOptimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours
van Elmpt, W., Hamill, J. J., Jones, J. P., Ruysscher, D. D., Lambin, P., & Öllers, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1716-6 · Cited by 117 · see citing works
Cine CT for Attenuation Correction in Cardiac PET/CT
Alessio, A. M., Kohlmyer, S. G., Branch, K. R., Chen, G., Caldwell, J. R., & Kinahan, P. E. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035717 · Cited by 109 · see citing works
Self-citation"Motion-frozen" display and quantification of myocardial perfusion.
Slomka, P. J., Nishina, H., Berman, D. S., Kang, X., Akincioğlu, Ç., Friedman, J. D., Hayes, S. W., Aladl, U. E., & Germano, G. (2004) · PubMed · Cited by 107 · see citing works
Self-citationCheng, V., Slomka, P. J., Meunier, L. L., Tamarappoo, B. K., Nakazato, R., Dey, D., & Berman, D. S. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.097550 · Cited by 106 · see citing works
Self-citationPET/CT imaging: Effect of respiratory motion on apparent myocardial uptake
Meunier, L. L., Maass‐Moreno, R., Carrasquillo, J. A., Dieckmann, W., & Bacharach, S. L. (2006) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2006.09.003 · Cited by 95 · see citing works
Practical PET Respiratory Motion Correction in Clinical PET/MR
Manber, R., Thielemans, K., Hutton, B. F., Barnes, A., Sebastien Ourselin, A., Arridge, S., O’Meara, C., Wan, S., & Atkinson, D. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.151779 · Cited by 83 · see citing works
Motion Correction of 18F-NaF PET for Imaging Coronary Atherosclerotic Plaques
Rubeaux, M., Joshi, N. V., Dweck, M. R., Fletcher, A. M., Motwani, M., Thomson, L., Germano, G., Dey, D., Li, D., Berman, D. S., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.162990 · Cited by 83 · see citing works
Self-citationLäutamaki, R., Brown, T. L. Y., Merrill, J., & Bengel, F. M. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0607-y · Cited by 82 · see citing works
Tadi, M. J., Koivisto, T., Pänkäälä, M., & Paasio, A. (2014) · International Journal of Biomedical Imaging · doi:10.1155/2014/690124 · Cited by 80 · see citing works
Dual-gated cardiac PET–Clinical feasibility study
Teräs, M., Kokki, T., Durand-Schaefer, N., Noponen, T., Pietilä, M., Kišš, J., Hoppela, E., Sipilä, H. T., & Knuuti, J. M. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1252-4 · Cited by 69 · see citing works
Nagel, C. C. A., Bosmans, G., Dekker, A. L. A. J., Öllers, M., Ruysscher, D. D., Lambin, P., Minken, A., Lang, N., & Schäfers, K. P. (2006) · Medical Physics · doi:10.1118/1.2198170 · Cited by 67 · see citing works
Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET
Kesner, A., Chung, J. H., Lind, K. E., Kwak, J., Lynch, D. A., Burckhardt, D., & Koo, P. J. (2016) · Radiology · doi:10.1148/radiol.2016152105 · Cited by 61 · see citing works
Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging
Lamare, F., Maitre, A. L., Dawood, M., Schäfers, K. P., Fernandez, P., Rimoldi, O. E., & Visvikis, D. (2014) · Medical Physics · doi:10.1118/1.4881099 · Cited by 58 · see citing works
Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny
Daou, D. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0931-x · Cited by 54 · see citing works
Dual-Gated Motion-Frozen Cardiac PET with Flurpiridaz F 18
Slomka, P. J., Rubeaux, M., Meunier, L. L., Dey, D., Lazewatsky, J. L., Pan, T., Dweck, M. R., Newby, D. E., Germano, G., & Berman, D. S. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.164285 · Cited by 53 · see citing works
Self-citationMotion frozen 18F-FDG cardiac PET
Meunier, L. L., Slomka, P. J., Dey, D., Ramesh, A., Thomson, L. E. J., Hayes, S. W., Friedman, J. D., Cheng, V., Germano, G., & Berman, D. S. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9322-3 · Cited by 49 · see citing works
Self-citationSuzuki, Y., Slomka, P. J., Wolak, A., Ohba, M., Suzuki, S., Yang, L., Germano, G., & Berman, D. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.050997 · Cited by 45 · see citing works
Self-citationAttenuation‐emission alignment in cardiac PET/CT based on consistency conditions
Alessio, A. M., Kinahan, P. E., Champley, K., & Caldwell, J. H. (2010) · Medical Physics · doi:10.1118/1.3315368 · Cited by 44 · see citing works
Self-citationEnhanced definition PET for cardiac imaging
Meunier, L. L., Slomka, P. J., Dey, D., Ramesh, A., Thomson, L. E. J., Hayes, S. W., Friedman, J. D., Cheng, V., Germano, G., & Berman, D. S. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9193-7 · Cited by 43 · see citing works
Self-citationSlomka, P. J., Díaz‐Zamudio, M., Dey, D., Motwani, M., Brodov, Y., Choi, D. J., Hayes, S. W., Thomson, L., Friedman, J. D., Germano, G., et al. (2015) · Journal of Nuclear Cardiology · doi:10.1007/s12350-014-0060-9 · Cited by 41 · see citing works
Self-citationA mass conservation‐based optical flow method for cardiac motion correction in 3D‐PET
Dawood, M., Gigengack, F., Jiang, X., & Schäfers, K. P. (2013) · Medical Physics · doi:10.1118/1.4770276 · Cited by 41 · see citing works
Woo, J., Tamarappoo, B. K., Dey, D., Nakazato, R., Meunier, L. L., Ramesh, A., Lazewatsky, J. L., Germano, G., Berman, D. S., & Slomka, P. J. (2011) · Medical Physics · doi:10.1118/1.3656951 · Cited by 40 · see citing works
Self-citationNoise Properties of Motion-Compensated Tomographic Image Reconstruction Methods
Chun, S. Y., & Fessler, J. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2206604 · Cited by 31 · see citing works
Koivumäki, T. M., Nekolla, S. G., Fürst, S., Loher, S., Vauhkonen, M. J., Schwaiger, M., & Hakulinen, M. A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/6373 · Cited by 18 · see citing works
Accuracy of amplitude-based respiratory gating for PET/CT in irregular respirations
Tsutsui, Y., Kidera, D., Taniguchi, T., Akamatsu, G., Komiya, I., Umezu, Y., Kitamura, Y., Baba, S., & Sasaki, M. (2014) · Annals of Nuclear Medicine · doi:10.1007/s12149-014-0870-5 · Cited by 17 · see citing works
Demons versus level-set motion registration for coronary 18F-sodium fluoride PET
Rubeaux, M., Joshi, N. V., Dweck, M. R., Fletcher, A. M., Motwani, M., Thomson, L., Germano, G., Dey, D., Berman, D. S., Newby, D. E., et al. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2217179 · Cited by 12 · see citing works
Self-citationThe strategy of elastic Motion corrections
Hong, I., Fürst, S., Jones, J. P., & Casey, M. (2013) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2013.6829009 · Cited by 6 · see citing works
Elastic motion correction for cardiac PET studies
Hong, I., Jones, J. P., & Casey, M. (2013) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2013.6829069 · Cited by 5 · see citing works
Rubeaux, M., Pawade, T., Cartlidge, T., Otaki, Y., Dweck, M. R., Dey, D., Germano, G., Newby, D. E., Berman, D. S., & Slomka, P. J. (2016) · Journal of Nuclear Medicine · Cited by 2 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis
Mahmood, M., Kendi, A. T., Ajmal, S., Farid, S., O’Horo, J. C., Chareonthaitawee, P., Baddour, L. M., & Sohail, M. R. (2017) · Journal of Nuclear Cardiology · doi:10.1007/s12350-017-1092-8 · Cited by 209 · see citing works
Forward to the Past: The Case for Quantitative PET Imaging
Lammertsma, A. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.188029 · Cited by 177 · see citing works
Mahmood, M., Kendi, A. T., Farid, S., Ajmal, S., Johnson, G. B., Baddour, L. M., Chareonthaitawee, P., Friedman, P. A., & Sohail, M. R. (2017) · Journal of Nuclear Cardiology · doi:10.1007/s12350-017-1063-0 · Cited by 117 · see citing works
MR/PET Imaging of the Cardiovascular System
Robson, P. M., Dey, D., Newby, D. E., Berman, D. S., Li, D., Fayad, Z. A., & Dweck, M. R. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.07.008 · Cited by 96 · see citing works
18F-FDG PET/CT in Infective Endocarditis: Indications and Approaches for Standardization
ten Hove, D., Slart, R. H. J. A., Sinha, B. N. M., Glaudemans, A. W. J. M., & Budde, R. P. J. (2021) · Current Cardiology Reports · doi:10.1007/s11886-021-01542-y · Cited by 81 · see citing works
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 50 · see citing works
“In cardiac PET imaging, contraction of the myocardium further contributes to the quantitative inaccuracy of uncorrected static PET protocols [90,91].”
BackgroundFully Automated, Fast Motion Correction of Dynamic Whole-Body and Total-Body PET/CT Imaging Studies
Sundar, L. K. S., Lassen, M. L., Gutschmayer, S., Ferrara, D., Calabrò, A., Yu, J., Kluge, K., Wang, Y., Nardo, L., Hasbak, P., et al. (2023) · Journal of Nuclear Medicine · doi:10.2967/jnumed.122.265362 · Cited by 47 · see citing works
Motion correction and its impact on quantification in dynamic total-body 18F-fluorodeoxyglucose PET
Sun, T., Wu, Y., Wei, W., Fu, F., Meng, N., Chen, H., Li, X., Bai, Y., Wang, Z., Ding, J., et al. (2022) · EJNMMI Physics · doi:10.1186/s40658-022-00493-9 · Cited by 45 · see citing works
Lee, B. C., Moody, J. B., Poitrasson-Rivière, A., Melvin, A. C., Weinberg, R. L., Corbett, J. R., Murthy, V. L., & Ficaro, E. P. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-01471-4 · Cited by 45 · see citing works
Automatic Inter-Frame Patient Motion Correction for Dynamic Cardiac PET Using Deep Learning
Shi, L., Lu, Y., Dvornek, N. C., Weyman, C. A., Miller, E. J., Sinusas, A. J., & Liu, C. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3082578 · Cited by 43 · see citing works
Kwieciński, J., Adamson, P. D., Lassen, M. L., Doris, M. K., Moss, A. J., Cadet, S., Jansen, M. A., Dey, D., Lee, S., Yun, M., et al. (2018) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.118.008325 · Cited by 42 · see citing works
Self-citationAnalytical quantification of aortic valve 18F-sodium fluoride PET uptake
Massera, D., Doris, M. K., Cadet, S. J., Kwieciński, J., Pawade, T., Peeters, F. E. C. M., Dey, D., Newby, D. E., Dweck, M. R., & Slomka, P. J. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-01542-6 · Cited by 40 · see citing works
Self-citationGating Approaches in Cardiac PET Imaging
Lassen, M. L., Kwiecinski, J., & Slomka, P. J. (2019) · PET Clinics · doi:10.1016/j.cpet.2018.12.008 · Cited by 38 · see citing works
Self-citationArmstrong, I. S., Hayden, C., Memmott, M. J., & Arumugam, P. (2020) · Journal of Nuclear Cardiology · doi:10.1007/s12350-020-02177-2 · Cited by 24 · see citing works
Body motion detection and correction in cardiac PET: Phantom and human studies
Sun, T., Petibon, Y., Han, P. K., Ma, C., Kim, S. J. W., Alpert, N. M., Fakhri, G. E., & Ouyang, J. (2019) · Medical Physics · doi:10.1002/mp.13815 · Cited by 23 · see citing works
Motion Correction and Its Impact on Absolute Myocardial Blood Flow Measures with PET
Piccinelli, M., Votaw, J. R., & Garcia, E. V. (2018) · Current Cardiology Reports · doi:10.1007/s11886-018-0977-8 · Cited by 22 · see citing works
Motion-correction strategies for enhancing whole-body PET imaging
Wang, J., Bermudez, D. H., Chen, W., Durgavarjhula, D., Randell, C., Uyanik, M., & McMillan, A. B. (2024) · Frontiers in Nuclear Medicine · doi:10.3389/fnume.2024.1257880 · Cited by 22 · see citing works
The Role of 18-F FDG PET/CT in Imaging of Endocarditis and Cardiac Device Infections
Mahmood, M., & Saleh, O. A. (2020) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2020.03.003 · Cited by 20 · see citing works
A Clinical Role of PET in Atherosclerosis and Vulnerable Plaques?
Lairez, O., & Hyafil, F. (2020) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2020.02.017 · Cited by 19 · see citing works
18F-sodium fluoride: An emerging tracer to assess active vascular microcalcification
Raynor, W., Borja, A. J., Rojulpote, C., Høilund‐Carlsen, P. F., & Alavi, A. A. (2020) · Journal of Nuclear Cardiology · doi:10.1007/s12350-020-02138-9 · Cited by 18 · see citing works
Saraste, A., Knuuti, J. M., & Bengel, F. M. (2023) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jead128 · Cited by 16 · see citing works
Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR
Marin, T., Djebra, Y., Han, P. K., Chemli, Y., Isabelle Bloch, A., Fakhri, G. E., Ouyang, J., Petibon, Y., & Ma, C. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abb31d · Cited by 15 · see citing works
Hyafil, F., & Vigne, J. (2019) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.119.312586 · Cited by 14 · see citing works
Lu, Z., Chen, G., Lyu, Y., Chen, Y., & Mok, G. S. P. (2022) · Medical Physics · doi:10.1002/mp.15682 · Cited by 12 · see citing works
Armstrong, I. S., Memmott, M. J., Hayden, C., & Arumugam, P. (2021) · Journal of Nuclear Cardiology · doi:10.1007/s12350-021-02531-y · Cited by 12 · see citing works
Schultz, J., Siekkinen, R., Tadi, M. J., Teräs, M., Klén, R., Lehtonen, E., Saraste, A., & Teuho, J. (2021) · Journal of Nuclear Cardiology · doi:10.1007/s12350-021-02769-6 · Cited by 11 · see citing works
Guo, X., Shi, L., Chen, X., Liu, Q., Zhou, B., Xie, H., Liu, Y.-H., Palyo, R., Miller, E. J., Sinusas, A. J., et al. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103190 · Cited by 8 · see citing works
Lehtonen, E., Teuho, J., Koskinen, J., Tadi, M. J., Klén, R., Siekkinen, R., Gambin, J. R., Vasankari, T., & Saraste, A. (2021) · Sensors · doi:10.3390/s21123983 · Cited by 8 · see citing works
Diagnostic imaging in infective endocarditis: a contemporary perspective
Almeida, N. E. C., Gurram, P. R., Garrigos, Z. E., Mahmood, M., Baddour, L. M., & Sohail, M. R. (2020) · Expert Review of Anti-infective Therapy · doi:10.1080/14787210.2020.1773260 · Cited by 8 · see citing works
Molecular Imaging of Heart Failure: An Update and Future Trends
Saraste, A., Ståhle, M. R., Roivainen, A., & Knuuti, J. M. (2024) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2024.03.005 · Cited by 7 · see citing works
Turco, A., Gheysens, O. S., Duchenne, J., Nuyts, J. L., Rega, F., Voigt, J., Vunckx, K., & Claus, P. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-01581-z · Cited by 6 · see citing works
Thompson, A. D., Ficaro, E. P., Murthy, V. L., & Weinberg, R. L. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-1185-z · Cited by 5 · see citing works
Nye, J. A., Piccinelli, M., Hwang, D., Cooke, C. D., Paeng, J. C., Lee, J. M., Cho, S., Folks, R. D., Bom, H., Koo, B., et al. (2021) · Medical Physics · doi:10.1002/mp.15059 · Cited by 5 · see citing works
Emerging Applications of Positron Emission Tomography in Coronary Artery Disease
Błach, A., & Kwieciński, J. (2025) · Journal of Personalized Medicine · doi:10.3390/jpm15030100 · Cited by 4 · see citing works
Bardane, A., Tajmouati, J., & Maghnouj, A. (2020) · Moscow University Physics Bulletin · doi:10.3103/s0027134920030054 · Cited by 4 · see citing works
Han, Y., Ahmed, A. I., Hayden, C., Jung, A. K., Saad, J. M., Spottiswoode, B. S., Nabi, F., & Al-Mallah, M. H. (2022) · Journal of Nuclear Cardiology · doi:10.1007/s12350-021-02902-5 · Cited by 4 · see citing works
Motion correction to enhance absolute myocardial blood flow quantitation by PET
Votaw, J. R., & Packard, R. R. S. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-01912-8 · Cited by 4 · see citing works
Aziz, R., Maebe, J., Muller, F. M., D’Asseler, Y., & Vandenberghe, S. (2024) · EJNMMI Physics · doi:10.1186/s40658-024-00704-5 · Cited by 2 · see citing works
Motion study on upright patient positioning in walk-through PET: evaluation in a clinical setting
Aziz, R., Muller, F. M., Withofs, N., Maebe, J., Dadgar, M., Vervenne, B., D’Asseler, Y., Vanhove, C., & Vandenberghe, S. (2025) · EJNMMI Physics · doi:10.1186/s40658-025-00815-7 · Cited by 1 · see citing works
Coronary artery disease imaging with total-body PET
Clark, L. E., Balmforth, C., Gil, M., Kwieciński, J., Slomka, P. J., Newby, D. E., Dweck, M. R., & Williams, M. C. (2026) · British Journal of Radiology · doi:10.1093/bjr/tqag093 · Cited by 1 · see citing works
Self-citationAdvances in Nuclear Cardiology: Instrumentation, Software and Radiopharmaceuticals
Özdemir, E., & Bedel, D. (2018) · Nuclear Medicine Seminars · doi:10.4274/nts.2018.018 · Cited by 1 · see citing works
Problems of Scintigraphic Diagnosis of Inflammatory Heart Disease and Methods of Their Correction
Il'iushenkova, I. N., Anashbaev, Z. Z., Popov, E. V., & Sazonova, S. I. (2022) · Medical Radiology and radiation safety · doi:10.33266/1024-6177-2022-67-2-32-37
Measurement of Myocardial Blood Flow by PET
Schelbert, H. R. (2024) · Oxford University Press eBooks · doi:10.1093/med/9780190095659.003.0009
Data-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans
Mendoza-Ibáñez, O. I., Slart, R. H. J. A., Hayden, C., Martínez-Lucio, T. S., van der Zant, F. M., Knol, R. J. J., & Lazarenko, S. V. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15030984
Sy, A., Seo, S., Silva, E. D., Lau, L., Amini, E., & Wiefels, C. (2026) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2026.102734
- Authors
- Rubeaux, M., Doris, M. K., Alessio, A., & Slomka, P. J.
- Affiliations
- Cedars-Sinai Medical Center (US)
- University of Washington (US)
- Corresponding author
- Slomka, Piotr J.
- Venue
- Current Cardiology Reports
- Published
- 2017-02
- Volume
- 19
- Issue
- 2
- Pages
- 14-14
- ISSN
- 1523-3782 (ISSN-L)
- 1534-3170
- OpenAlex
- W2586752887
- Cited by
- 48
- References
- 58
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 5 · 2021: 6 · 2020: 8 · 2019: 5 · 2018: 6 · 2017: 4
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Cardiology Reports (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R01HL109327)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- cardiac PET, motion correction, respiratory gating, cardiac gating, non-rigid registration, CT attenuation correction, PET image reconstruction, image artifacts, spatial resolution
- MeSH terms
- Positron Emission Tomography Computed Tomography, Algorithms, Coronary Artery Disease, Heart, Humans, Image Processing, Computer-Assisted, Motion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review