The DOI matches its Crossref record.
Internal‐external correlation investigations of respiratory induced motion of lung tumors
Abstract
In gated radiation therapy procedures, the lung tumor position is used directly (by implanted radiopaque markers) or indirectly (by external surrogate methods) to decrease the volume of irradiated healthy tissue. Due to a risk of pneumothorax, many clinics do not implant fiducials, and the gated treatment is primarily based on a respiratory induced external signal. The external surrogate method relies upon the assumption that the internal tumor motion is well correlated with the external respiratory induced motion, and that this correlation is constant in time. Using a set of data that contains synchronous internal and external motion traces, we have developed a dynamic data analysis technique to study the internal‐external correlation, and to quantitatively estimate its underlying time behavior. The work presented here quantifies the time dependent behavior of the correlation between external respiratory signals and lung implanted fiducial motion. The corresponding amplitude mismatch is also reported for the lung patients studied. The information obtained can be used to improve the accuracy of tumor tracking. For the ten patients in this study, the SI internal‐external motion is well correlated, with small time shifts and corresponding amplitude mismatches. Although the AP internal‐external motion reveals larger time shifts than along the SI direction, the corresponding amplitude mismatches are below .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
Hoogeman, M., Prévost, J.-B., Nuyttens, J., Pöll, J., Levendag, P., & Heijmen, B. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.12.041 · Cited by 327
Motion in radiotherapy: particle therapy
Bert, C., & Durante, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/r01 · Cited by 315
Hurkmans, C. W., Cuijpers, J. P., Lagerwaard, F. J., Widder, J., van der Heide, U. A., Schuring, D., & Senan, S. (2009) · Radiation Oncology · doi:10.1186/1748-717x-4-1 · Cited by 287
Metadata
- Authors
- Ionascu, D., Jiang, S. B., Nishioka, S., Shirato, H., & Berbeco, R. I.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2007-09-19
- Volume
- 34
- Issue
- 10
- Pages
- 3893-3903
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1980707615
- Cited by
- 209
- References
- 0
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Internal‐external correlation investigations of respiratory induced motion of lung tumors. https://app.cochat.ai/papers/10.1118/1.2779941
- The paper
- Ionascu, D., Jiang, S. B., Nishioka, S., Shirato, H., & Berbeco, R. I. (2007). Internal‐external correlation investigations of respiratory induced motion of lung tumors. Medical Physics. https://doi.org/10.1118/1.2779941
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.