The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Motion in radiotherapy: particle therapy
Abstract
Charged particle beam radiotherapy requires dedicated measures to compensate for the dosimetric influence of inter- and intra-fractional target motion. Independent of the delivery technique, these measures have to incorporate the strong influence of the radiological depth on the delivered dose. For scanned beam delivery, interference effects of target motion and scanned beam can further cause under-dosage of the clinical target volume despite using margins. Within the scope of this review, published data with respect to motion management in scattered as well as scanned beam treatment delivery will be summarized. Based on a section covering the dosimetric impact of organ motion, motion management during treatment planning, patient positioning, treatment delivery and treatment validation will be summarized. For scattered beam delivery, the concepts and data are often based on clinical usage since treatment of moving tumors has been performed for several years. In the field of scanned beam delivery, the report focuses on the results of research on countermeasures of the interference effect. Clinical application of these techniques can be expected in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093 · cited 1×
“Several algorithms and implementations are reported in the literature and are commercially available (Brock et al 2006, Hill et al 2001, Kessler 2006, Rietzel and Chen 2006, Sarrut 2006, Wang et al 2005, Yang et al 2008).”
MethodPrescribing, recording, and reporting photon beam therapy
Icru (1993) · Medical Entomology and Zoology · Cited by 1,996
Zietman, A. L., DeSilvio, M. L., Slater, J. D., Rossi, C. J., Miller, D. W., Adams, J. A., & Shipley, W. U. (2005) · JAMA · doi:10.1001/jama.294.10.1233 · Cited by 1,224
The use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 912
Charged particles in radiation oncology
Durante, M., & Loeffler, J. S. (2010) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.183 · Cited by 737
Self-citationMagnetic scanning system for heavy ion therapy
Haberer, T., Becher, W., Schardt, D., & Kraft, G. (1993) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(93)91335-k · Cited by 730
The Cyberknife: A Frameless Robotic System for Radiosurgery
Adler Jr., J. R., Chang, S. D., Murphy, M. J., Doty, J., Geis, P., & Hancock, S. L. (1997) · Stereotactic and Functional Neurosurgery · doi:10.1159/000099863 · Cited by 671
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
Cited by
Charged-particle therapy in cancer: clinical uses and future perspectives
Durante, M., Orecchia, R., & Loeffler, J. S. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.30 · Cited by 484
Self-citationCharged particle therapy—optimization, challenges and future directions
Loeffler, J. S., & Durante, M. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.79 · Cited by 426
Self-citationRespiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
Towards clinical translation of FLASH radiotherapy
Vozenin, M.-C., Bourhis, J., & Durante, M. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00697-z · Cited by 363
Self-citationNuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Self-citation
Metadata
- Authors
- Bert, C., & Durante, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-07-20
- Volume
- 56
- Issue
- 16
- Pages
- R113-R144
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2143101233
- Cited by
- 315
- References
- 54
- FWCI
- 26.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motion in radiotherapy: particle therapy. https://app.cochat.ai/papers/10.1088/0031-9155/56/16/r01
- The paper
- Bert, C., & Durante, M. (2011). Motion in radiotherapy: particle therapy. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/16/r01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.