Volumetric modulated arc therapy: IMRT in a single gantry arc
Open accessAbstract
In this work a novel plan optimization platform is presented where treatment is delivered efficiently and accurately in a single dynamically modulated arc. Improvements in patient care achieved through image‐guided positioning and plan adaptation have resulted in an increase in overall treatment times. Intensity‐modulated radiation therapy (IMRT) has also increased treatment time by requiring a larger number of beam directions, increased monitor units (MU), and, in the case of tomotherapy, a slice‐by‐slice delivery. In order to maintain a similar level of patient throughput it will be necessary to increase the efficiency of treatment delivery. The solution proposed here is a novel aperture‐based algorithm for treatment plan optimization where dose is delivered during a single gantry arc of up to 360 deg. The technique is similar to tomotherapy in that a full 360 deg of beam directions are available for optimization but is fundamentally different in that the entire dose volume is delivered in a single source rotation. The new technique is referred to as volumetric modulated arc therapy (VMAT). Multileaf collimator (MLC) leaf motion and number of MU per degree of gantry rotation is restricted during the optimization so that gantry rotation speed, leaf translation speed, and dose rate maxima do not excessively limit the delivery efficiency. During planning, investigators model continuous gantry motion by a coarse sampling of static gantry positions and fluence maps or MLC aperture shapes. The technique presented here is unique in that gantry and MLC position sampling is progressively increased throughout the optimization. Using the full gantry range will theoretically provide increased flexibility in generating highly conformal treatment plans. In practice, the additional flexibility is somewhat negated by the additional constraints placed on the amount of MLC leaf motion between gantry samples. A series of studies are performed that characterize the relationship between gantry and MLC sampling, dose modeling accuracy, and optimization time. Results show that gantry angle and MLC sample spacing as low as 1 deg and 0.5 cm, respectively, is desirable for accurate dose modeling. It is also shown that reducing the sample spacing dramatically reduces the ability of the optimization to arrive at a solution. The competing benefits of having small and large sample spacing are mutually realized using the progressive sampling technique described here. Preliminary results show that plans generated with VMAT optimization exhibit dose distributions equivalent or superior to static gantry IMRT. Timing studies have shown that the VMAT technique is well suited for on‐line verification and adaptation with delivery times that are reduced to for a 200 cGy fraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yan, D., Vicini, F., Wong, J., & Martinez, A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/008 · Cited by 761
Cited by
Radiation oncology in the era of precision medicine
Baumann, M., Krause, M., Overgaard, J., Debus, J., Bentzen, S. M., Daartz, J., Richter, C., Zips, D., & Bortfeld, T. (2016) · Nature Reviews Cancer · doi:10.1038/nrc.2016.18 · Cited by 812
Volumetric modulated arc therapy: a review of current literature and clinical use in practice
Teoh, M., Clark, C. H., Wood, K., Whitaker, S., & Nisbet, A. (2011) · The British Journal of Radiology · doi:10.1259/bjr/22373346 · Cited by 762
Cancer treatments: Past, present, and future
Sonkin, D., Thomas, A., & Teicher, B. A. (2024) · Cancer Genetics · doi:10.1016/j.cancergen.2024.06.002 · Cited by 548
Predicting dose‐volume histograms for organs‐at‐risk in IMRT planning
Appenzoller, L. M., Michalski, J. M., Thorstad, W. L., Mutic, S., & Moore, K. L. (2012) · Medical Physics · doi:10.1118/1.4761864 · Cited by 382
Nguyen, D., Jia, X., Sher, D., Lin, M.-H., Iqbal, Z., Liu, H., & Jiang, S. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab039b · Cited by 318
Metadata
- Authors
- Otto, K.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2007-12-26
- Volume
- 35
- Issue
- 1
- Pages
- 310-317
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2084851290
- Cited by
- 1,882
- References
- 1
- FWCI
- 66.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetric modulated arc therapy: IMRT in a single gantry arc. https://app.cochat.ai/papers/10.1118/1.2818738
- The paper
- Otto, K. (2008). Volumetric modulated arc therapy: IMRT in a single gantry arc. Medical Physics. https://doi.org/10.1118/1.2818738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.