The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture
Open accessAbstract
The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human expertise and a tremendous amount of effort to produce personalized high quality plans, taking as long as a week, which deteriorates the chances of tumor control and patient survival. To solve this problem, we propose to investigate a deep learning-based dose prediction model, Hierarchically Densely Connected U-net, based on two highly popular network architectures: U-net and DenseNet. We find that this new architecture is able to accurately and efficiently predict the dose distribution, outperforming the other two models, the Standard U-net and DenseNet, in homogeneity, dose conformity, and dose coverage on the test data. Averaging across all organs at risk, our proposed model is capable of predicting the organ-at-risk max dose within 6.3% and mean dose within 5.1% of the prescription dose on the test data. The other models, the Standard U-net and DenseNet, performed worse, having an averaged organ-at-risk max dose prediction error of 8.2% and 9.3%, respectively, and averaged mean dose prediction error of 6.4% and 6.8%, respectively. In addition, our proposed model used 12 times less trainable parameters than the Standard U-net, and predicted the patient dose 4 times faster than DenseNet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
Fully convolutional networks for semantic segmentation
Long, J., Shelhamer, E., & Darrell, T. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298965 · Cited by 38,834
Breiman, L. (1996) · Machine Learning · doi:10.1007/bf00058655 · Cited by 16,325
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
Milletari, F., Navab, N., & Ahmadi, S.-A. (2016) · 2016 Fourth International Conference on 3D Vision (3DV) · doi:10.1109/3dv.2016.79 · Cited by 11,931
Fully convolutional networks for semantic segmentation
Shelhamer, E., Long, J., & Darrell, T. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2572683 · Cited by 11,898
Backpropagation Applied to Handwritten Zip Code Recognition
LeCun, Y., Boser, B., Denker, J. S., Henderson, D., Howard, R. E., Hubbard, W., & Jackel, L. D. (1989) · Neural Computation · doi:10.1162/neco.1989.1.4.541 · Cited by 11,891
H-DenseUNet: Hybrid Densely Connected UNet for Liver and Tumor Segmentation From CT Volumes
Li, X., Chen, H., Qi, X., Dou, Q., Fu, C.-W., & Heng, P.-A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2845918 · Cited by 2,473
Volumetric modulated arc therapy: IMRT in a single gantry arc
Otto, K. (2008) · Medical Physics · doi:10.1118/1.2818738 · Cited by 1,882
Cited by
Artificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Self-citationRevolutionizing radiation therapy: the role of AI in clinical practice
Kawamura, M., Kamomae, T., Yanagawa, M., Kamagata, K., Fujita, S., Ueda, D., Matsui, Y., Fushimi, Y., Fujioka, T., Nozaki, T., et al. (2024) · Journal of Radiation Research · doi:10.1093/jrr/rrad090 · Cited by 86
Barragán-Montero, A. M., Thomas, M., Defraene, G., Michiels, S., Haustermans, K., Lee, J. A., & Sterpin, E. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.026 · Cited by 69
A feasibility study of automating radiotherapy planning with large language model agents
Wang, Q., Wang, Z., Li, M., Ni, X., Tan, R., Zhang, W., Wubulaishan, M., Wang, W., Yuan, Z., Zhang, Z., et al. (2025) · Physics in Medicine & Biology · doi:10.1088/1361-6560/adbff1 · Cited by 28
A Survey on Deep Learning for Precision Oncology
Wang, C.-W., Khalil, M.-A., & Firdi, N. (2022) · Diagnostics · doi:10.3390/diagnostics12061489 · Cited by 23
Metadata
- Authors
- Nguyen, D., Jia, X., Sher, D., Lin, M.-H., Iqbal, Z., Liu, H., & Jiang, S.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-03-18
- Volume
- 64
- Issue
- 6
- Pages
- 065020
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2804847842
- Cited by
- 318
- References
- 33
- FWCI
- 27.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture. https://app.cochat.ai/papers/10.1088/1361-6560/ab039b
- The paper
- Nguyen, D., Jia, X., Sher, D., Lin, M.-H., Iqbal, Z., Liu, H., & Jiang, S. (2019). 3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab039b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.