Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record.

Quantitative comparison of direct phase retrieval algorithms in in‐line phase tomography

Langer, Max, Cloetens, Peter, Guigay, Jean‐Pierre, Peyrin, Françoise · 2008 · Medical Physics

Abstract

A well‐known problem in x‐ray microcomputed tomography is low sensitivity. Phase contrast imaging offers an increase of sensitivity of up to a factor of in the hard x‐ray region, which makes it possible to image soft tissue and small density variations. If a sufficiently coherent x‐ray beam, such as that obtained from a third generation synchrotron, is used, phase contrast can be obtained by simply moving the detector downstream of the imaged object. This setup is known as in‐line or propagation based phase contrast imaging. A quantitative relationship exists between the phase shift induced by the object and the recorded intensity and inversion of this relationship is called phase retrieval. Since the phase shift is proportional to projections through the three‐dimensional refractive index distribution in the object, once the phase is retrieved, the refractive index can be reconstructed by using the phase as input to a tomographic reconstruction algorithm. A comparison between four phase retrieval algorithms is presented. The algorithms are based on the transport of intensity equation (TIE), transport of intensity equation for weak absorption, the contrast transfer function (CTF), and a mixed approach between the CTF and TIE, respectively. The compared methods all rely on linearization of the relationship between phase shift and recorded intensity to yield fast phase retrieval algorithms. The phase retrieval algorithms are compared using both simulated and experimental data, acquired at the European Synchrotron Radiation Facility third generation synchrotron light source. The algorithms are evaluated in terms of two different reconstruction error metrics. While being slightly less computationally effective, the mixed approach shows the best performance in terms of the chosen criteria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.2975224

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Langer, M., Cloetens, P., Guigay, J., & Peyrin, F.
Venue
Medical Physics
Publisher
Wiley
Published
2008-09-18
Volume
35
Issue
10
Pages
4556-4566
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2066200146
Cited by
179
References
0
FWCI
11.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative comparison of direct phase retrieval algorithms in in‐line phase tomography. https://app.cochat.ai/papers/10.1118/1.2975224
The paper
Langer, M., Cloetens, P., Guigay, J., & Peyrin, F. (2008). Quantitative comparison of direct phase retrieval algorithms in in‐line phase tomography. Medical Physics. https://doi.org/10.1118/1.2975224

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.