The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Abstract
Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single shot phase contrast imaging using laser-produced Betatron x-ray beams
Fourmaux, S., Corde, S., Phuoc, K. T., Lassonde, P., Lebrun, G., Payeur, S., Martin, F., Sebban, S., Malka, V., Rousse, A., et al. (2011) · Optics Letters · doi:10.1364/ol.36.002426 · Cited by 138
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Hot‐Pressed CsPbBr3 Quasi‐Monocrystalline Film for Sensitive Direct X‐ray Detection
Pan, W., Yang, B., Niu, G., Xue, K., Du, X., Yin, L., Zhang, M., Wu, H., Miao, X., & Tang, J. (2019) · Advanced Materials · doi:10.1002/adma.201904405 · Cited by 346
Otake, Y., Schafer, S., Stayman, J. W., Zbijewski, W., Kleinszig, G., Graumann, R., Khanna, A. J., & Siewerdsen, J. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5485 · Cited by 79
Advantages of phase retrieval for fast x-ray tomographic microscopy
Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G. K., Krapp, H. G., Skeren, M., & Stampanoni, M. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/49/494004 · Cited by 56
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Metadata
- Authors
- Bravin, A., Coan, P., & Suortti, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-12-10
- Volume
- 58
- Issue
- 1
- Pages
- R1-R35
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2105286970
- Cited by
- 846
- References
- 1
- FWCI
- 97.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray phase-contrast imaging: from pre-clinical applications towards clinics. https://app.cochat.ai/papers/10.1088/0031-9155/58/1/r1
- The paper
- Bravin, A., Coan, P., & Suortti, P. (2013). X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/58/1/r1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.