Stochastic rank correlation: A robust merit function for 2D/3D registration of image data obtained at different energies
Open accessAbstract
In this article, the authors evaluate a merit function for 2D/3D registration called stochastic rank correlation (SRC). SRC is characterized by the fact that differences in image intensity do not influence the registration result; it therefore combines the numerical advantages of cross correlation (CC)-type merit functions with the flexibility of mutual-information-type merit functions. The basic idea is that registration is achieved on a random subset of the image, which allows for an efficient computation of Spearman's rank correlation coefficient. This measure is, by nature, invariant to monotonic intensity transforms in the images under comparison, which renders it an ideal solution for intramodal images acquired at different energy levels as encountered in intrafractional kV imaging in image-guided radiotherapy. Initial evaluation was undertaken using a 2D/3D registration reference image dataset of a cadaver spine. Even with no radiometric calibration, SRC shows a significant improvement in robustness and stability compared to CC. Pattern intensity, another merit function that was evaluated for comparison, gave rather poor results due to its limited convergence range. The time required for SRC with 5% image content compares well to the other merit functions; increasing the image content does not significantly influence the algorithm accuracy. The authors conclude that SRC is a promising measure for 2D/3D registration in IGRT and image-guided therapy in general.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Comparative studies suggest that local metrics tend to demonstrate better performance than global metrics.
“Although the best performing similarity metric is application-dependent, comparative studies (Birkfellner et al 2009, Russakoff et al 2003) suggest that local metrics tend to demonstrate better performance.”
From Robust 3D–2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation (2013) · cites this paper as Birkfellner et al 2009
The Introduction lists local normalized correlation among registration metrics, but does not compare local metrics with global ones. The Results compare specific methods—SRC, cross correlation, and pattern intensity—and report that SRC performed best in the tested setup. Those findings do not establish the claimed general tendency for local metrics to perform better. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 43
- [1]Dawson LA Jaffray DA Advances in image-guided radiation therapy J. Clin. Oncol 2007 25 8 938 946 17350942
- [2]Elshaikh M Ljungman M Haken R. Ten Lichter AS Advances in radiation oncology Annu. Rev. Med 2006 57 19 31 16409134
- [3]Jans HS Syme AM Rathee S Fallone BG 3D interfractional patient position verification using 2D-3D registration of orthogonal images Med. Phys 2006 33 5 1420 1439 16752578
- [4]Meyer J Richter A Baier K Wilbert J Guckenberger M Flentje M Tracking moving objects with megavoltage portal imaging: A feasibility study Med. Phys 2006 33 5 1275 1280 16752562
- [5]Künzler T Grezdo J Bogner J Birkfellner W Georg D Registration of DRRs and portal images for verification of stereotactic body radiotherapy: A feasibility study in lung cancer treatment Phys. Med. Biol 2007 52 8 2157 2170 17404461
- [6]Lemieux L Jagoe R Fish DR Kitchen ND Thomas DGT A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs Med. Phys 1994 21 11 1749 1760 7891637
- [7]Penney GP Weese J Little JA Desmedt P Hill DLG Hawkes DJ A comparison of similarity measures for use in 2-D-3-D medical image registration IEEE Trans. Med. Imaging 1998 17 4 586 595 9845314
- [8]Turgeon GA Lehmann G Guiraudon G Drangova M Holdsworth D Peters T 2D-3D registration of coronary angiograms for cardiac procedure planning and guidance Med. Phys 2005 32 12 3737 3749 16475773
- [9]Balter JM Kessler ML Imaging and alignment for image-guided radiation therapy J. Clin. Oncol 2007 25 8 931 937 17350941
- [10]Khamene A Bloch P Wein W Svatos M Sauer F Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy Med. Image Anal 2006 10 96 112 16150629
- [11]Dong S Kettenbach J Hinterleitner I Bergmann H Birkfellner W The Zernike expansion—an example of a merit function for 2D/3D registration based on orthogonal functions MICCAI 2008 11 2 964 971 18982698
- [12]Maes F Collignon A Vandermeulen D Marchal G Suetens P Multimodality image registration by maximization of mutual information IEEE Trans. Med. Imaging 1997 16 2 187 198 9101328
- [13]Wells WM III Viola P Atsumi H Nakajima S Kikinis R Multi-modal volume registration by maximization of mutual information Med. Image Anal 1996 1 1 35 51 9873920
- [14]Studholme C Hill DL Hawkes DJ Automated 3D registration of MR and CT images of the head Med. Image Anal 1996 1 2 163 175 9873927
- [15]Pluim JP Maintz JB Viergever MA Mutual-information-based registration of medical images: A survey IEEE Trans. Med. Imaging 2003 22 8 986 1004 12906253
- [16]Fei B Duerk JL Boll DT Lewin JS Wilson DL Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer IEEE Trans. Med. Imaging 2003 22 4 515 525 12774897
- [17]Birkfellner W Figl M Kettenbach J Hummel J Homolka P Schernthaner R Nau T Bergmann H Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images Med. Phys 2007 34 1 246 255 17278510
- [18]Lacroute P Levoy M Fast volume rendering using a shear-warp factorization of the viewing transformation 451 458 Proceedings of SIGGRAPH ’94 1994 ACM New York
- [19]Russakoff DB Rohlfing T Mori K Rueckert D Ho A Adler JR Jr. Maurer CR Jr. Fast generation of digitally reconstructed radiographs using attenuation fields with application to 2D-3D image registration IEEE Trans. Med. Imaging 2005 24 11 1441 1454 16279081
- [20]Knaan D Joskowicz L Effective intensity-based 2D/3D rigid registration between fluoroscopic x-ray and CT MICCAI 2003 6 1 351 358
- [21]Zöllei L Grimson E Norbash A Wells W 2D-3D rigid registration of x-ray fluoroscopy and CT images using mutual information and sparsely sampled histogram estimators Proceedings of IEEE CVPR 2001 IEEE Computer Society New York
- [22]Spoerk J Bergmann H Wanschitz F Dong S Birkfellner W Fast DRR splat rendering using common consumer graphics hardware Med. Phys 2007 34 11 4302 4308 18072495
- [24]Birkfellner W Seemann R Figl M Hummel J Ede C Homolka P Yang X Niederer P Bergmann H Wobbled splatting—a fast perspective colume rendering method for simulation of x-ray images from CT Phys. Med. Biol 2005 50 9 N73 N84 15843725
- [25]Birkfellner W Wirth J Burgstaller W Baumann B Staedele H Hammer B Gellrich NC Jacob AL Regazzoni P Messmer P A faster method for 2D/3D medical image registration Phys. Med. Biol 2003 48 16 2665 2679 12974581
- [26]Andrews DW Bednarz G Evans JJ Downes B A review of 3 current radiosurgery systems Surg. Neurol 2006 66 6 559 564 17145309
- [27]van de Kraats EB Penney GP Tomazevic D van Walsum T Niessen WJ Standardized evaluation methodology for 2-D-3-D registration IEEE Trans. Med. Imaging 2005 24 9 1177 1189 16156355
- [28]Tomazevic D Likar B Pernus F 3-D/2-D registration by integrating 2-D information in 3-D IEEE Trans. Med. Imaging 2006 25 1 17 27 16398411
- [29]Frühwald L Kettenbach J Figl M Hummel J Bergmann H Birkfellner W A comparative study on manual and automatic slice-to-volume registration of CT images Eur. Radiol (in press) PMC2855949 19504108
- [30]Archip N Statli P Morrison P Jolesz F Warfield SK Silverman S Non-rigid registration of pre-procedural MR images with intra-procedural unenhanced CT-images for improved targeting of tumors during liver radiofrequency ablations MICCAI 2007 10 2 969 977 18044662
- [31]Dey J Napel S Targeted 2D/3D registration using ray normalization and a hybrid optimizer Med. Phys 2006 33 12 4730 4738 17278825
- [32]Russakoff DB Rohlfing T Ho A Kim DH Shahidi R Adler JR Jr. Maurer CR Jr. Evaluation of intensity-based 2D-3D spine image registration using clinical gold-standard data 151 160 Proceedings of the second International Workshop on Biomedical Image Registration 2003 Springer Philadelphia, PA Paper No. LNCS 2717
- [33]Robb RA Hanson DP Karwoski RA Larson AG Workman EL Stacy MC Analyze: A comprehensive, operator-interactive software package for multidimensional medical image display and analysis Comput. Med. Imaging Graph 1989 13 6 433 454 2688869
- [34]Tewatia D Zhang T Tome W Paliwal B Metha M Clinical implementation of target tracking by breathing synchronized delivery Med. Phys 2006 33 11 4330 4336 17153412
- [35]Sharp GC Jiang SB Shimizu S Shirato H Prediction of respiratory tumour motion for real-time image-guided radiotherapy Phys. Med. Biol 2004 49 3 425 440 15012011
- [36]Tang X Sharp GC Jiang SB Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking Phys. Med. Biol 2007 52 4081 4098 17664596
- [37]Rohlfing T Denzler J Grassl C Russakoff DB Maurer CR Jr. Markerless real-time 3-D target region tracking by motion backprojection from projection images IEEE Trans. Med. Imaging 2005 24 11 1455 1468 16279082
- [38]Zeng R Fessler JA Balter JM Estimating 3-D respiratory motion from orbiting views by tomographic image registration IEEE Trans. Med. Imaging 2007 26 2 153 163 17304730 PMC2851164
- [39]Lehmann GC Holdsworth DW Drangova M Angle-independent measure of motion for image-based gating in 3D coronary angiography Med. Phys 2006 33 5 1311 1320 16752566
- [40]Shimizu S Shirato H Ogura S Akita-Dosaka H Kitamura K Nishioka T Kagei K Nishimura M Miyasaka K Detection of lung tumor movement in real-time tumor-tracking radiotherapy Int. J. Radiat. Oncol., Biol., Phys 2001 51 2 304 310 11567803
- [41]Shirato H Shimizu S Kitamura K Onimaru R Organ motion in image-guided radiotherapy: Lessons from real-time tumor tracking radiotherapy Int. J. Clin. Oncol 2007 12 1 8 16 17380435
- [42]Suh Y Dieterich S Keall PJ Geometric uncertainty of 2D projection imaging in monitoring 3D tumor motion Phys. Med. Biol 2007 52 3439 3454 17664553
- [43]Hummel J Figl M Kollmann C Bergmann H Birkfellner W Evaluation of a miniature electromagnetic position tracker Med. Phys 2002 29 10 2205 2212 12408292
- [44]Kupelian P Willoughby T Mahadevan A Djemil T Weinstein G Jani S Enke C Solberg T Flores N Liu D Beyer D Levine L Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy Int. J. Radiat. Oncol., Biol., Phys 2007 67 4 1088 1098 17187940
Cited by
Sorted by citations
A CNN Regression Approach for Real-Time 2D/3D Registration
Miao, S., Wang, Z. J., & Liao, R. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2521800 · Cited by 514 · see citing works
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 85 · see citing works
“Although the best performing similarity metric is application-dependent, comparative studies (Birkfellner et al 2009, Russakoff et al 2003) suggest that local metrics tend to demonstrate better performance.”
MethodKhayyeri, H., Väänänen, S. P., Flivik, G., Jurvelin, J. S., Dahlberg, L., & Isaksson, H. (2020) · Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization · doi:10.1080/21681163.2019.1578266
- Authors
- Birkfellner, W., Stock, M., Figl, M., Gendrin, C., Hummel, J., Dong, S., Kettenbach, J., Georg, D., & Bergmann, H.
- Affiliations
- Medical University of Vienna (AT)
- Corresponding author
- Birkfellner, Wolfgang
- ORCID
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-07-01
- Volume
- 36
- Issue
- 8
- Pages
- 3420-3428
- ISSN
- 0094-2405 (ISSN-L)
- PMC
- PMC2855948
- OpenAlex
- W2035539344
- Cited by
- 44
- References
- 0
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 4 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 2 · 2016: 4 · 2015: 1 · 2014: 4 · 2013: 2 · 2012: 4
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Medical Physics (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- BORIS (University Library Bern) (submittedVersion)
- Funders
- Eurasia-Pacific Uninet Foundation (P19931)
- Austrian Science Foundation FWF (L503)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- 2D-3D registration, merit function, image-guided radiotherapy, intensity invariance, Spearman correlation, cross correlation function, mutual information, radiometric calibration
- MeSH terms
- Cadaver, Humans, Reference Standards, Spine, Stochastic Processes, Time Factors, Tomography, X-Ray Computed, Phantoms, Imaging, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review