CoChat

The DOI matches its Crossref record; 31 of the 37 references it cites were found in a registry or an index.

A CNN Regression Approach for Real-Time 2D/3D Registration

Miao, Shun, Wang, Z. Jane, Liao, Rui · 2016 · IEEE Transactions on Medical Imaging

Abstract

In this paper, we present a Convolutional Neural Network (CNN) regression approach to address the two major limitations of existing intensity-based 2-D/3-D registration technology: 1) slow computation and 2) small capture range. Different from optimization-based methods, which iteratively optimize the transformation parameters over a scalar-valued metric function representing the quality of the registration, the proposed method exploits the information embedded in the appearances of the digitally reconstructed radiograph and X-ray images, and employs CNN regressors to directly estimate the transformation parameters. An automatic feature extraction step is introduced to calculate 3-D pose-indexed features that are sensitive to the variables to be regressed while robust to other factors. The CNN regressors are then trained for local zones and applied in a hierarchical manner to break down the complex regression task into multiple simpler sub-tasks that can be learned separately. Weight sharing is furthermore employed in the CNN regression model to reduce the memory footprint. The proposed approach has been quantitatively evaluated on 3 potential clinical applications, demonstrating its significant advantage in providing highly accurate real-time 2-D/3-D registration with a significantly enlarged capture range when compared to intensity-based methods.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmi.2016.2521800

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

4 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 37 references

Research works printed but not linked: 1

  1. vetter, 2014, Validation of a virtual implant planning system (VIPS) in distal radius fractures, Bone Joint J Orthopaedic Proc Supplement, 96, 50

Cited by

See all 514

Metadata

Authors
Miao, S., Wang, Z. J., & Liao, R.
Affiliations
  • University of British Columbia (CA)
  • Siemens (United States) (US)
Venue
IEEE Transactions on Medical Imaging
Published
2016-05
Volume
35
Issue
5
Pages
1352-1363
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2344328023
Cited by
514
References
37
Citations by year
2026: 23 · 2025: 40 · 2024: 56 · 2023: 57 · 2022: 55 · 2021: 64 · 2020: 60 · 2019: 76 · 2018: 41 · 2017: 38 · 2016: 4
FWCI
35.73
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
Keywords
2D-3D registration, convolutional neural network regression, intensity-based registration, real-time registration, digitally reconstructed radiographs, X-ray images, automatic feature extraction, hierarchical regression, parameter sharing, capture range, transformation parameter estimation
MeSH terms
Machine Learning, Humans, Knee Joint, Radiography, Regression Analysis, Neural Networks, Computer, Echocardiography, Transesophageal, Arthroplasty, Replacement, Knee, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A CNN Regression Approach for Real-Time 2D/3D Registration. https://app.cochat.ai/papers/10.1109/tmi.2016.2521800
The paper
Miao, S., Wang, Z. J., & Liao, R. (2016). A CNN Regression Approach for Real-Time 2D/3D Registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2016.2521800

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.