Abstract
Purpose: The authors develop a practical, iterative algorithm for image‐reconstruction in undersampled tomographic systems, such as digital breast tomosynthesis (DBT). Methods: The algorithm controls image regularity by minimizing the image total variation (TpV), a function that reduces to the total variation when or the image roughness when . Constraints on the image, such as image positivity and estimated projection‐data tolerance, are enforced by projection onto convex sets. The fact that the tomographic system is undersampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) Reduction in the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in undersampled tomography. Results: The proposed image‐reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses. Conclusions: Results indicate that there may be a substantial advantage in using the present image‐reconstruction algorithm for microcalcification imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Self-citationExact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Cited by
Pan, X., Sidky, E. Y., & Vannier, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123009 · Cited by 572
Self-citationEvaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Self-citationImproved total variation-based CT image reconstruction applied to clinical data
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/003 · Cited by 306
Metadata
- Authors
- Sidky, E. Y., Pan, X., Reiser, I. S., Nishikawa, R. M., Moore, R. H., & Kopans, D. B.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-10-02
- Volume
- 36
- Issue
- 11
- Pages
- 4920-4932
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2001134459
- Cited by
- 181
- References
- 4
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image‐reconstruction algorithms. https://app.cochat.ai/papers/10.1118/1.3232211
- The paper
- Sidky, E. Y., Pan, X., Reiser, I. S., Nishikawa, R. M., Moore, R. H., & Kopans, D. B. (2009). Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image‐reconstruction algorithms. Medical Physics. https://doi.org/10.1118/1.3232211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.