Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)

Open access
Choi, Kihwan, Wang, Jing, Zhu, Lei, Suh, Tae‐Suk, Boyd, Stephen, Xing, Lei·2010·Medical Physics

Abstract

Purpose: This article considers the problem of reconstructing cone‐beam computed tomography (CBCT) images from a set of undersampled and potentially noisy projection measurements. Methods: The authors cast the reconstruction as a compressed sensing problem based on norm minimization constrained by statistically weighted least‐squares of CBCT projection data. For accurate modeling, the noise characteristics of the CBCT projection data are used to determine the relative importance of each projection measurement. To solve the compressed sensing problem, the authors employ a method minimizing total‐variation norm, satisfying a prespecified level of measurement consistency using a first‐order method developed by Nesterov. Results: The method converges fast to the optimal solution without excessive memory requirement, thanks to the method of iterative forward and back‐projections. The performance of the proposed algorithm is demonstrated through a series of digital and experimental phantom studies. It is found a that high quality CBCT image can be reconstructed from undersampled and potentially noisy projection data by using the proposed method. Both sparse sampling and decreasing x‐ray tube current (i.e., noisy projection data) lead to the reduction of radiation dose in CBCT imaging. Conclusions: It is demonstrated that compressed sensing outperforms the traditional algorithm when dealing with sparse, and potentially noisy, CBCT projection views.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3481510

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Metadata

Authors
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L.
Venue
Medical Physics
Publisher
Wiley
Published
2010-08-31
Volume
37
Issue
9
Pages
5113-5125
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2042653706
Cited by
255
References
43
FWCI
21.16
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda). https://app.cochat.ai/papers/10.1118/1.3481510
The paper
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010). Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda). Medical Physics. https://doi.org/10.1118/1.3481510

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.