The feasibility of patient size‐corrected, scanner‐independent organ dose estimates for abdominal CT exams
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: A recent work has demonstrated the feasibility of estimating the dose to individual organs from multidetector CT exams using patient‐specific, scanner‐independent‐to‐organ‐dose conversion coefficients. However, the previous study only investigated organ dose to a single patient model from a full‐body helical CT scan. The purpose of this work was to extend the validity of this dose estimation technique to patients of any size undergoing a common clinical exam. This was done by determining the influence of patient size on organ dose conversion coefficients generated for typical abdominal CT exams. Methods: Monte Carlo simulations of abdominal exams were performed using models of 64‐slice MDCT scanners from each of the four major manufacturers to obtain dose to radiosensitive organs for eight patient models of varying size, age, and gender. The scanner‐specific organ doses were normalized by corresponding values and averaged across scanners to obtain scanner‐independent ‐to‐organ‐dose conversion coefficients for each patient model. In order to obtain a metric for patient size, the outer perimeter of each patient was measured at the central slice of the abdominal scan region. Then, the relationship between ‐to‐organ‐dose conversion coefficients and patient perimeter was investigated for organs that were directly irradiated by the abdominal scan. These included organs that were either completely (“fully irradiated”) or partly (“partially irradiated”) contained within the abdominal exam region. Finally, dose to organs that were not at all contained within the scan region (“nonirradiated”) were compared to the doses delivered to fully irradiated organs. Results: ‐to‐organ‐dose conversion coefficients for fully irradiated abdominal organs had a strong exponential correlation with patient perimeter. Conversely, partially irradiated organs did not have a strong dependence on patient perimeter. In almost all cases, the doses delivered to nonirradiated organs were less than 5%, on average across patient models, of the mean dose of the fully irradiated organs. Conclusions: This work demonstrates the feasibility of calculating patient‐specific, scanner‐independent‐to‐organ‐dose conversion coefficients for fully irradiated organs in patients undergoing typical abdominal CT exams. A method to calculate patient‐specific, scanner‐specific, and exam‐specific organ dose estimates that requires only knowledge of the for the scan protocol and the patient's perimeter is thus possible. This method will have to be extended in future studies to include organs that are partially irradiated. Finally, it was shown that, in most cases, the doses to nonirradiated organs were small compared to the dose to fully irradiated organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
Self-citationMcCollough, C., Bakalyar, D., Bostani, M., Brady, S., Boedeker, K., Boone, J., Chen-Mayer, H. H., Christianson, O., Leng, S., Li, B., et al. (2014) · doi:10.37206/146 · Cited by 171
“showed that using CTDIvol as a normalization factor, organ dose estimates can be obtained for a specific patient size [2], and that the relationship to patient size was consistent across scanner models [3].”
MethodSelf-citationFranck, C., Vandevoorde, C., Goethals, I., Smeets, P., Achten, E., Verstraete, K., Thierens, H., & Bacher, K. (2016) · European Radiology · doi:10.1007/s00330-015-4091-7 · Cited by 43
“Turner et al performed Monte Carlo simulations on eight different voxelbased models, including two paediatric models [35].”
MethodDose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., et al. (2021) · Radiation Research · doi:10.1667/rade-20-00231.1 · Cited by 31
“The Dutch study was partially supported by Worldwide Cancer Research, formally known as the Association for International Cancer Research (12-1155).”
MethodNoferini, L., Fulcheri, C., Taddeucci, A., Bartolini, M., & Gori, C. (2014) · Radiological Physics and Technology · doi:10.1007/s12194-014-0265-2 · Cited by 16
Metadata
- Authors
- Turner, A. C., Zhang, D., Khatonabadi, M., Zankl, M., DeMarco, J. J., Cagnon, C. H., Cody, D. D., Stevens, D. M., McCollough, C. H., & McNitt‐Gray, M. F.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-01-20
- Volume
- 38
- Issue
- 2
- Pages
- 820-829
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1971221307
- Cited by
- 149
- References
- 0
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The feasibility of patient size‐corrected, scanner‐independent organ dose estimates for abdominal CT exams. https://app.cochat.ai/papers/10.1118/1.3533897
- The paper
- Turner, A. C., Zhang, D., Khatonabadi, M., Zankl, M., DeMarco, J. J., Cagnon, C. H., Cody, D. D., Stevens, D. M., McCollough, C. H., & McNitt‐Gray, M. F. (2011). The feasibility of patient size‐corrected, scanner‐independent organ dose estimates for abdominal CT exams. Medical Physics. https://doi.org/10.1118/1.3533897
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.