The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging
Open accessAbstract
Purpose: Magnetic particle imaging (MPI), using magnetite nanoparticles (MNPs) as tracer material, shows great promise as a platform for fast tomographic imaging. To date, the magnetic properties of MNPs used in imaging have not been optimized. As nanoparticle magnetism shows strong size dependence, the authors explore how varying MNP size impacts imaging performance in order to determine optimal MNP characteristics for MPI at any driving field frequency. Methods: Monodisperse MNPs of varying size were synthesized and their magnetic properties characterized. Their MPI response was measured experimentally using a custom‐built MPI transceiver designed to detect the third harmonic of MNP magnetization. The driving field amplitude and frequency were chosen to be suitable for imaging small animals. Experimental results were interpreted using a model of dynamic MNP magnetization that is based on the Langevin theory of superparamagnetism and accounts for sample size distribution and size‐dependent magnetic relaxation. Results: The experimental results show a clear variation in the MPI signal intensity as a function of MNP diameter that is in agreement with simulated results. A maximum in the plot of MPI signal vs MNP size indicates there is a particular size that is optimal for the chosen. Conclusions: The authors observed that MNPs 15 nm in diameter generate maximum signal amplitude in MPI experiments at 250 kHz. The authors expect the physical basis for this result, the change in magnetic relaxation with MNP size, will impact MPI under other experimental conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-large-scale syntheses of monodisperse nanocrystals
Park, J., An, K., Hwang, Y., Park, J.-G., Noh, H.-J., Kim, J.-Y., Park, J.-H., Hwang, N.-M., & Hyeon, T. (2004) · Nature Materials · doi:10.1038/nmat1251 · Cited by 4,076
Cited by
Magnetic Nanoparticles in Cancer Therapy and Diagnosis
Farzin, A., Etesami, S. A., Quint, J., Memic, A., & Tamayol, A. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901058 · Cited by 562
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Advances in the Application of Magnetic Nanoparticles for Sensing
Gloag, L., Mehdipour, M., Chen, D., Tilley, R. D., & Gooding, J. J. (2019) · Advanced Materials · doi:10.1002/adma.201904385 · Cited by 364
Synthesis of phase-pure and monodisperse iron oxide nanoparticles by thermal decomposition
Hufschmid, R., Arami, H., Ferguson, R. M., Gonzales, M., Teeman, E., Brush, L. N., Browning, N. D., & Krishnan, K. M. (2015) · Nanoscale · doi:10.1039/c5nr01651g · Cited by 341
Self-citationMagnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Metadata
- Authors
- Ferguson, R. M., Minard, K. R., Khandhar, A. P., & Krishnan, K. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-02-28
- Volume
- 38
- Issue
- 3
- Pages
- 1619-1626
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2025535587
- Cited by
- 162
- References
- 1
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging. https://app.cochat.ai/papers/10.1118/1.3554646
- The paper
- Ferguson, R. M., Minard, K. R., Khandhar, A. P., & Krishnan, K. M. (2011). Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging. Medical Physics. https://doi.org/10.1118/1.3554646
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.