Compton scatter effects in CT reconstructions
Abstract
Compton scatter of x‐ray quanta is the dominant attenuation mechanism in medical diagnostic imaging. In this paper, it is shown that the scatter‐to‐primary ratio determines the nature and intensity of scatter artifacts in computed tomography (CT) reconstructions and that this ratio, while significantly lower than in radiographic and fluoroscopic examinations, can still be significant in CT. It is found that high spatial‐frequency artifacts can arise even though the detected scatter intensity has little or no high‐frequency modulation. Reconstructions from x‐ray data are presented which show “cupping” as well as dark streaks connecting high‐attenuation regions. Correction of the data from measurements of scatter eliminates these artifacts. It is, moreover, observed that the intensity of the artifacts is often diminished when a beam‐shaping attenuator is employed. Calculations of scatter intensity are developed from a model which includes single‐event and two‐event scatter. This analysis is in good agreement with measurements on round water phantoms. Extension to other detector geometries shows, not unexpectedly, that detectors with poorer collimation yield larger scatter artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cone‐beam volume CT breast imaging: Feasibility study
Chen, B., & Ning, R. (2002) · Medical Physics · doi:10.1118/1.1461843 · Cited by 277
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Metadata
- Authors
- Glover, G. H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1982-11
- Volume
- 9
- Issue
- 6
- Pages
- 860-867
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2033978387
- Cited by
- 167
- References
- 0
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compton scatter effects in CT reconstructions. https://app.cochat.ai/papers/10.1118/1.595197
- The paper
- Glover, G. H. (1982). Compton scatter effects in CT reconstructions. Medical Physics. https://doi.org/10.1118/1.595197
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.