Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 168

The DOI matches its Crossref record.

Coherent scatter in diagnostic radiology

Johns, P. C., Yaffe, M. J. · 1983 · Medical Physics

Abstract

Coherent scatter is often ignored in diagnostic radiology because its cross section is relatively small, and because it is assumed to be indistinguishable from primary radiation. Single‐scatter calculations, however, show that coherently scattered photons diverge sufficiently from the primary ray to degrade image contrast, and that they account for a significant fraction of the total scattered energy fluence at the image receptor. Grids and large air gaps are less effective in reducing coherent single scatter than incoherent and multiple scatter. For radiography of the abdomen, coherent first scatter comprises 10% of total scatter and 26% of the primary fluence before a grid, and on the order of 22% and 7.5%, respectively, behind a grid. Coherent first scatter comprises a higher fraction of the total amount of scatter for lower energy examinations such as mammography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.595443

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Johns, P. C., & Yaffe, M. J.
Venue
Medical Physics
Publisher
Wiley
Published
1983-01
Volume
10
Issue
1
Pages
40-50
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W1965711063
Cited by
168
References
0
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coherent scatter in diagnostic radiology. https://app.cochat.ai/papers/10.1118/1.595443
The paper
Johns, P. C., & Yaffe, M. J. (1983). Coherent scatter in diagnostic radiology. Medical Physics. https://doi.org/10.1118/1.595443

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.