Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record.

Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting

Cho, Z. H., Kim, D. J., Kim, Y. K.·1988·Medical Physics

Abstract

A correction technique of the total magnetic field inhomogeneity effects including the localized object induced inhomogeneities such as chemical shift and susceptibility is developed and its usefulness is experimentally demonstrated. With this new and simple technique all the inhomogeneity induced artifacts can be corrected simultaneously. The basic idea of this method is to add a compensation gradient of the same amplitude as the selection gradient in simultaneity with the reading gradient in such a way that the view angle is tilted. Thereby all the inhomogeneity induced geometrical shifts and hence the intensity changes are corrected, since the addition of the compensation which is independent from the field inhomogeneities including both chemical shifts and susceptibility. This technique has been theoretically examined and its usefulness is demonstrated by experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.596162

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 217

Metadata

Authors
Cho, Z. H., Kim, D. J., & Kim, Y. K.
Venue
Medical Physics
Publisher
Wiley
Published
1988-01
Volume
15
Issue
1
Pages
7-11
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W1973148314
Cited by
217
References
0
FWCI
1.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. https://app.cochat.ai/papers/10.1118/1.596162
The paper
Cho, Z. H., Kim, D. J., & Kim, Y. K. (1988). Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. Medical Physics. https://doi.org/10.1118/1.596162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.