The DOI matches its Crossref record.
Maximum likelihood analysis of free‐response receiver operating characteristic (FROC) data
Abstract
Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free‐response receiver operating characteristic (FROC) methodology offers a more natural framework to describe observer performance in such studies and has other advantages. Due to the lack of a statistical analysis procedure comparable to the maximum likelihood procedure (rocfit program) available for ROC studies, the FROC method has not gained widespread acceptance. This work presents and solves a two parameter model for the statistical analysis of FROC data. The model assumes that the probability density of the signal stimuli is normally distributed, as is the probability density for producing one or more false positives per image. A program (frocfit) is described for estimating the parameters and their uncertainties from experimental data. An index of performance is proposed to quantify observer performance in FROC experiments. Application of this methodology to several FROC data sets produced good to excellent fits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Observer studies involving detection and localization: Modeling, analysis, and validation
Chakraborty, D. P., & Berbaum, K. S. (2004) · Medical Physics · doi:10.1118/1.1769352 · Cited by 351
Self-citationCurrent perspectives in medical image perception
Krupinski, E. A. (2010) · Attention, Perception & Psychophysics · doi:10.3758/app.72.5.1205 · Cited by 343
Obuchowski (2005) · doi:10.2214/ajr.184.2.01840364 · Cited by 321
Lewin, J. M., Hendrick, R. E., D’Orsi, C. J., Isaacs, P. K., Moss, L. J., Karellas, A., Sisney, G. A., Kuni, C. C., & Cutter, G. R. (2001) · Radiology · doi:10.1148/radiology.218.3.r01mr29873 · Cited by 303
Computer-Aided Detection and Diagnosis in Mammography
Sampat, M. P., Markey, M. K., & Bovik, A. C. (2005) · Handbook of Image and Video Processing · doi:10.1016/b978-012119792-6/50130-3 · Cited by 302
Metadata
- Authors
- Chakraborty, D. P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1989-07
- Volume
- 16
- Issue
- 4
- Pages
- 561-568
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2095485540
- Cited by
- 202
- References
- 0
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maximum likelihood analysis of free‐response receiver operating characteristic (FROC) data. https://app.cochat.ai/papers/10.1118/1.596358
- The paper
- Chakraborty, D. P. (1989). Maximum likelihood analysis of free‐response receiver operating characteristic (FROC) data. Medical Physics. https://doi.org/10.1118/1.596358
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.