Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 206

The DOI matches its Crossref record.

Grids or air gaps for scatter reduction in digital radiography: A model calculation

Neitzel, Ulrich · 1992 · Medical Physics

Abstract

The relative advantages of grids and air gaps for scatter reduction in a digital radiography system were investigated using a theoretical model. In this model the properties of the scatter reduction device are described by primary transmission and selectivity. The signal-to-noise (SNR) improvement factor for fixed exposure to the patient was used as a performance indicator. The results show that the SNR improvement depends strongly on the local scatter fraction; for all practical configurations, however, it stays below a factor of 2. For high scatter fractions, an air gap of 20 cm has about the same effect on SNR improvement as a highly selective grid; for low and medium scatter conditions the air gap performs better than any grid. Additive system noise reduces the SNR improvement factor compared to the case with quantum noise only, the reduction being more pronounced for the grids than for the air gap. The results suggest that the use of an air gap instead of a grid is advantageous in digital radiography systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.596836

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Neitzel, U.
Venue
Medical Physics
Publisher
Wiley
Published
1992-03
Volume
19
Issue
2
Pages
475-481
ISSN
0094-2405 (ISSN-L)
OpenAlex
W2002057038
Cited by
206
References
0
FWCI
1.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Grids or air gaps for scatter reduction in digital radiography: A model calculation. https://app.cochat.ai/papers/10.1118/1.596836
The paper
Neitzel, U. (1992). Grids or air gaps for scatter reduction in digital radiography: A model calculation. Medical Physics. https://doi.org/10.1118/1.596836

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.