The DOI matches its Crossref record.
Grids or air gaps for scatter reduction in digital radiography: A model calculation
Abstract
The relative advantages of grids and air gaps for scatter reduction in a digital radiography system were investigated using a theoretical model. In this model the properties of the scatter reduction device are described by primary transmission and selectivity. The signal-to-noise (SNR) improvement factor for fixed exposure to the patient was used as a performance indicator. The results show that the SNR improvement depends strongly on the local scatter fraction; for all practical configurations, however, it stays below a factor of 2. For high scatter fractions, an air gap of 20 cm has about the same effect on SNR improvement as a highly selective grid; for low and medium scatter conditions the air gap performs better than any grid. Additive system noise reduces the SNR improvement factor compared to the case with quantum noise only, the reduction being more pronounced for the grids than for the air gap. The results suggest that the use of an air gap instead of a grid is advantageous in digital radiography systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
Mozzo, P., Procacci, C., Tacconi, A., Tinazzi Martini, P., & Bergamo Andreis, I. A. (1998) · European Radiology · doi:10.1007/s003300050586 · Cited by 1,383
Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
Siewerdsen, J. H., & Jaffray, D. A. (2001) · Medical Physics · doi:10.1118/1.1339879 · Cited by 612
Conebeam CT of the Head and Neck, Part 1: Physical Principles
Miracle, A. C., & Mukherji, S. K. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1653 · Cited by 387
X‐ray scatter correction algorithm for cone beam CT imaging
Ning, R., Tang, X., & Conover, D. (2004) · Medical Physics · doi:10.1118/1.1711475 · Cited by 322
Siewerdsen, J. H., Daly, M. J., Bakhtiar, B., Moseley, D. J., Richard, S., Keller, H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2148916 · Cited by 283
Metadata
- Authors
- Neitzel, U.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1992-03
- Volume
- 19
- Issue
- 2
- Pages
- 475-481
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2002057038
- Cited by
- 206
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grids or air gaps for scatter reduction in digital radiography: A model calculation. https://app.cochat.ai/papers/10.1118/1.596836
- The paper
- Neitzel, U. (1992). Grids or air gaps for scatter reduction in digital radiography: A model calculation. Medical Physics. https://doi.org/10.1118/1.596836
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.