X‐ray scatter correction algorithm for cone beam CT imaging

Ning, Ruola, Tang, Xiangyang, Conover, David·2004·Medical Physics

Abstract

Developing and optimizing an x‐ray scatter control and reduction technique is one of the major challenges for cone beam computed tomography (CBCT) because CBCT will be much less immune to scatter than fan‐beam CT. X‐ray scatter reduces image contrast, increases image noise and introduces reconstruction error into CBCT. To reduce scatter interference, a practical algorithm that is based upon the beam stop array technique and image sequence processing has been developed on a flat panel detector‐based CBCT prototype scanner. This paper presents a beam stop array‐based scatter correction algorithm and the evaluation results through phantom studies. The results indicate that the beam stop array‐based scatter correction algorithm is practical and effective to reduce and correct x‐ray scatter for a CBCT imaging task.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.1711475

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 322

Metadata

Authors
Ning, R., Tang, X., & Conover, D.
Venue
Medical Physics
Publisher
Wiley
Published
2004-04-20
Volume
31
Issue
5
Pages
1195-1202
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2060434533
Cited by
322
References
0
FWCI
10.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: X‐ray scatter correction algorithm for cone beam CT imaging. https://app.cochat.ai/papers/10.1118/1.1711475
The paper
Ning, R., Tang, X., & Conover, D. (2004). X‐ray scatter correction algorithm for cone beam CT imaging. Medical Physics. https://doi.org/10.1118/1.1711475

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.