Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA
The DOI matches its Crossref record.
Abstract
A simulation study was performed to evaluate a new set of calibration standards for estimating the fat content of the body via dual‐photon absorptiometry (DPA) and dual‐energy x‐ray absorptiometry (DXA). The standards, proposed by Nord and Payne [presented at the 2nd meeting of The Bath Conference on Bone Mineral Measurement (1990)] consist of stearic acid (100% fat) and 0.6% NaCl in water (100% lean). They were compared with other standards consisting of average composition adipose/muscle tissues and fatty adipose / lean muscle tissues. Source and detector properties of a Gd‐153 DPA system and three commercial DXA systems were modeled. For each system and calibration set, rms errors in the calculated fat contents of simulated tissues having fat mass percentages that ranged from about 4%–44% and thicknesses that ranged from 5–20 cm were determined. Beam hardening errors for the systems were evaluated as was a calibration technique employed by one of the manufacturers to correct for such errors. In general, the smallest rms errors (2% or less when the calibration standards and tissues were of equal thickness) were obtained with the average adipose/muscle standards. Equivalent results were obtained with standards consisting of stearic acid and 0.8% NaCl. The latter is a higher salt content than proposed by Nord and Payne and results from differences in the x‐ray attenuation coefficients that were employed in calculating the fat equivalence of water. Other, more convenient standards, such as lucite and water may be employed by using appropriate fat equivalences (∼69% for lucite and ∼10% for water). Beam hardening errors for the DXA systems are considerable, and the simulated correction technique was shown to be effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Contemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Clinical Applications of Body Composition Measurements Using DXA
Albanese, C. V., Diessel, E., & Genant, H. K. (2003) · Journal of Clinical Densitometry · doi:10.1385/jcd:6:2:75 · Cited by 276
Kohrt, W. M., Ehsani, A. A., & Birge, S. J. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.8.1253 · Cited by 271
“5 g of bone mineral for each 1 kg reduction in fat mass and further demonstrated that this was not due to technical error associated with X-ray beam hardening effects.((29)) If the finding of Jensen et al.”
BackgroundPercent body fat via DEXA: comparison with a four-compartment model
van der Ploeg, G. E., Withers, R. T., & Laforgia, J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00436.2002 · Cited by 163
Metadata
- Authors
- Goodsitt, M. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 19
- Issue
- 1
- Pages
- 35-44
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2028611263
- Cited by
- 66
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA. https://app.cochat.ai/papers/10.1118/1.596890
- The paper
- Goodsitt, M. M. (1992). Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA. Medical Physics. https://doi.org/10.1118/1.596890
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.