Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA

Goodsitt, Mitchell M. · 1992 · Medical Physics
Cited by 66

The DOI matches its Crossref record.

Abstract

A simulation study was performed to evaluate a new set of calibration standards for estimating the fat content of the body via dual‐photon absorptiometry (DPA) and dual‐energy x‐ray absorptiometry (DXA). The standards, proposed by Nord and Payne [presented at the 2nd meeting of The Bath Conference on Bone Mineral Measurement (1990)] consist of stearic acid (100% fat) and 0.6% NaCl in water (100% lean). They were compared with other standards consisting of average composition adipose/muscle tissues and fatty adipose / lean muscle tissues. Source and detector properties of a Gd‐153 DPA system and three commercial DXA systems were modeled. For each system and calibration set, rms errors in the calculated fat contents of simulated tissues having fat mass percentages that ranged from about 4%–44% and thicknesses that ranged from 5–20 cm were determined. Beam hardening errors for the systems were evaluated as was a calibration technique employed by one of the manufacturers to correct for such errors. In general, the smallest rms errors (2% or less when the calibration standards and tissues were of equal thickness) were obtained with the average adipose/muscle standards. Equivalent results were obtained with standards consisting of stearic acid and 0.8% NaCl. The latter is a higher salt content than proposed by Nord and Payne and results from differences in the x‐ray attenuation coefficients that were employed in calculating the fat equivalence of water. Other, more convenient standards, such as lucite and water may be employed by using appropriate fat equivalences (∼69% for lucite and ∼10% for water). Beam hardening errors for the DXA systems are considerable, and the simulated correction technique was shown to be effective.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.596890

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 66

Metadata

Authors
Goodsitt, M. M.
Venue
Medical Physics
Publisher
Wiley
Published
1992-01
Volume
19
Issue
1
Pages
35-44
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2028611263
Cited by
66
References
0
FWCI
1.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA. https://app.cochat.ai/papers/10.1118/1.596890
The paper
Goodsitt, M. M. (1992). Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA. Medical Physics. https://doi.org/10.1118/1.596890

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.