CoChat

Three‐dimensional verification of patient placement during radiotherapy using portal images

Bijhold, J. · 1993 · Medical Physics
Cited by 62

The DOI matches its Crossref record.

Abstract

The use of a single portal image for the three‐dimensional verification of patient placement during radiotherapy has been investigated. In this study, a deviation in the patient positioning is quantified by a three‐dimensional translation and rotation of the patient. The parameter values are obtained by fitting the projections of anatomical match points in the simulator and the portal image, using the three‐dimensional gantry coordinates of these points in the intended treatment setup. Two methods for finding an analytical solution for the fitting problem are presented. One method yields a solution from the affine transformation of the portal image (shift, rotation, magnification, and stretching in a specified direction) that fits the projections of the match points on the simulator image. The second and more accurate method yields a solution that expresses the estimated parameter values and their covariances as functions of image and three‐dimensional gantry coordinates of the selected matchpoints. The robustness and sensitivity of the solution is implicitly given by these expressions. The applications of these methods are illustrated by experiments with a human pelvic bone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.597075

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bijhold, J.
Venue
Medical Physics
Publisher
Wiley
Published
1993-03
Volume
20
Issue
2
Pages
347-356
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2048304362
Cited by
62
References
0
FWCI
3.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.