The DOI matches its Crossref record.
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
Abstract
This paper describes BEAM, a general purpose Monte Carlo code to simulate the radiation beams from radiotherapy units including high‐energy electron and photon beams, 60 Co beams and ortho‐voltage units. The code handles a variety of elementary geometric entities which the user puts together as needed (jaws, applicators, stacked cones, mirrors, etc.), thus allowing simulation of a wide variety of accelerators. The code is not restricted to cylindrical symmetry. It incorporates a variety of powerful variance reduction techniques such as range rejection, bremsstrahlung splitting and forcing photon interactions. The code allows direct calculation of charge in the monitor ion chamber. It has the capability of keeping track of each particle's history and using this information to score separate dose components (e.g., to determine the dose from electrons scattering off the applicator). The paper presents a variety of calculated results to demonstrate the code's capabilities. The calculated dose distributions in a water phantom irradiated by electron beams from the NRC 35 MeV research accelerator, a Varian Clinac 2100C, a Philips SL75‐20, an AECL Therac 20 and a Scanditronix MM50 are all shown to be in good agreement with measurements at the 2 to 3% level. Eighteen electron spectra from four different commercial accelerators are presented and various aspects of the electron beams from a Clinac 2100C are discussed. Timing requirements and selection of parameters for the Monte Carlo calculations are discussed. Dedication: This paper is dedicated to the memory of our friend and colleague, Jiansu Wei, who made a significant contribution to this project before he passed away on March 15, 1993.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures
Petoussi-Henss, N., Bolch, W. E., Eckerman, K. F., Endo, A., Hertel, N., Hunt, J., Pelliccioni, M., Schlattl, H., & Zankl, M. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2011.10.001 · Cited by 721
Sechopoulos, I., Ali, E. S. M., Badal, A., Badano, A., Boone, J. M., Kyprianou, I. S., Mainegra‐Hing, E., McMillan, K. L., McNitt‐Gray, M. F., Rogers, D. W. O., et al. (2015) · Medical Physics · doi:10.1118/1.4928676 · Cited by 109
Self-citation
Metadata
- Authors
- Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. ‐., We, J., & Mackie, T. R.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 22
- Issue
- 5
- Pages
- 503-524
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2091361931
- Cited by
- 1,431
- References
- 0
- FWCI
- 20.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BEAM: A Monte Carlo code to simulate radiotherapy treatment units. https://app.cochat.ai/papers/10.1118/1.597552
- The paper
- Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. ‐., We, J., & Mackie, T. R. (1995). BEAM: A Monte Carlo code to simulate radiotherapy treatment units. Medical Physics. https://doi.org/10.1118/1.597552
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.