Monte Carlo reference data sets for imaging research: Executive summary of the report of AAPM Research Committee Task Group 195
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The use of Monte Carlo simulations in diagnostic medical imaging research is widespread due to its flexibility and ability to estimate quantities that are challenging to measure empirically. However, any new Monte Carlo simulation code needs to be validated before it can be used reliably. The type and degree of validation required depends on the goals of the research project, but, typically, such validation involves either comparison of simulation results to physical measurements or to previously published results obtained with established Monte Carlo codes. The former is complicated due to nuances of experimental conditions and uncertainty, while the latter is challenging due to typical graphical presentation and lack of simulation details in previous publications. In addition, entering the field of Monte Carlo simulations in general involves a steep learning curve. It is not a simple task to learn how to program and interpret a Monte Carlo simulation, even when using one of the publicly available code packages. This Task Group report provides a common reference for benchmarking Monte Carlo simulations across a range of Monte Carlo codes and simulation scenarios. In the report, all simulation conditions are provided for six different Monte Carlo simulation cases that involve common x-ray based imaging research areas. The results obtained for the six cases using four publicly available Monte Carlo software packages are included in tabular form. In addition to a full description of all simulation conditions and results, a discussion and comparison of results among the Monte Carlo packages and the lessons learned during the compilation of these results are included. This abridged version of the report includes only an introductory description of the six cases and a brief example of the results of one of the cases. This work provides an investigator the necessary information to benchmark his/her Monte Carlo simulation software against the reference cases included here before performing his/her own novel research. In addition, an investigator entering the field of Monte Carlo simulations can use these descriptions and results as a self-teaching tool to ensure that he/she is able to perform a specific simulation correctly. Finally, educators can assign these cases as learning projects as part of course objectives or training programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Studies where multiple modeling groups attempt to solve the same pre-specified problem have been useful in various fields for code verification and, more generally, for scientific reproducibility [48–50].”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Hubbell, J. H., & Seltzer, S. M. (1995) · doi:10.6028/nist.ir.5632 · Cited by 2,033
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. ‐., We, J., & Mackie, T. R. (1995) · Medical Physics · doi:10.1118/1.597552 · Cited by 1,431
Self-citationThe EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport
Kawrakow, I., Mainegra‐Hing, E., & Tessier, F. (2016) · NPARC · Cited by 1,137
Self-citationKawrakow, I. (2000) · Medical Physics · doi:10.1118/1.598917 · Cited by 945
Absorbed Radiation Dose in Mammography
Richard Hammerstein, G., Miller, D. W., White, D. R., Ellen Masterson, M., Woodard, H. Q., & Laughlin, J. S. (1979) · Radiology · doi:10.1148/130.2.485 · Cited by 549
Catalogue of diagnostic x-ray spectra and other data
Cranley, K. (1997) · Medical Entomology and Zoology · Cited by 418
An algorithm for Monte Carlo simulation of coupled electron-photon transport
Sempau, J., Acosta, E., Baro, J., Fernández-Varea, J. M., & Salvat, F. (1997) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(97)00414-x · Cited by 391
Sempau, J., Badal, A., & Brualla, L. (2011) · Medical Physics · doi:10.1118/1.3643029 · Cited by 277
Self-citation
Research works printed but not linked: 3
- 10.1016/s0168‐9002(03)01368‐8 · DOI · Paper page
- D. B. Pelowitz, J. S. Hendricks, J. W. Durkee, M. R. James, M. L. Fensin, G. W. McKinney, S. G. Mashnik, and L. S. Waters, X 2.7.A Extensions-Report LA-UR-08-07182, Los Alamos, NM, 2008.
- International Commission on Radiation Units and Measurements, "Photon, electron, proton, and neutron interaction data for body tissues," ICRU Report No. 46 (International Commission on Radiation Units and Measurements, Bethesda, MD, 1992).
Cited by
Sechopoulos, I., Rogers, D. W. O., Bazalova‐Carter, M., Bolch, W. E., Heath, E. C., McNitt‐Gray, M. F., Sempau, J., & Williamson, J. F. (2018) · Medical Physics · doi:10.1002/mp.12702 · Cited by 302
Self-citationHernandez, A. M., Seibert, J. A., & Boone, J. M. (2015) · Medical Physics · doi:10.1118/1.4931966 · Cited by 85
Self-citationGeneration and analysis of clinically relevant breast imaging x-ray spectra
Hernandez, A. M., Seibert, J. A., Nosratieh, A., & Boone, J. M. (2017) · Medical Physics · doi:10.1002/mp.12222 · Cited by 72
Self-citationMammography and breast tomosynthesis simulator for virtual clinical trials
Badal, A., Sharma, D., Graff, C. G., Zeng, R., & Badano, A. G. (2020) · Computer Physics Communications · doi:10.1016/j.cpc.2020.107779 · Cited by 68
Self-citationCredibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
Self-citation
Metadata
- Authors
- Sechopoulos, I., Ali, E. S. M., Badal, A., Badano, A., Boone, J. M., Kyprianou, I. S., Mainegra‐Hing, E., McMillan, K. L., McNitt‐Gray, M. F., Rogers, D. W. O., Samei, E., & Turner, A. C.
- Affiliations
- Emory University (US)
- Ottawa Hospital (CA)
- United States Food and Drug Administration (US)
- University of California, Davis (US)
- National Research Council Canada (CA)
- University of California, Los Angeles (US)
- Carleton University (CA)
- Duke University (US)
- Corresponding author
- Sechopoulos, Ioannis
- ORCID
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2015-09-08
- Volume
- 42
- Issue
- 10
- Pages
- 5679-5691
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1943832849
- Cited by
- 109
- References
- 22
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 9 · 2023: 8 · 2022: 7 · 2021: 14 · 2020: 12 · 2019: 16 · 2018: 12 · 2017: 11 · 2016: 5 · 2015: 2
- FWCI
- 8.09
- Type
- journal article
- Language
- en
- Update notices
- tg-report (2015-10-01)
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- onlinelibrary.wiley.com/termsAndConditions#am (am, 366 d)
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- creativecommons.org/licenses/by/3.0/ (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Medical Physics (publishedVersion, cc-by)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (publishedVersion)
- Radboud Repository (Radboud University) (publishedVersion)
- NPARC (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Funders
- U.S. Department of Energy (Department of Energy) (DE-AC02-76SF00515)
- U.S. Department of Energy (DE‐AC02‐76SF00515, DE-AC02-76SF00515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- Monte Carlo simulation, simulation benchmarking, reference dataset, diagnostic imaging, radiography, simulation validation, simulation-based training
- MeSH terms
- Breast, Humans, Monte Carlo Method, Reference Standards, Tomography, X-Ray Computed, Benchmarking, Research Report
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monte Carlo reference data sets for imaging research: Executive summary of the report of AAPM Research Committee Task Group 195. https://app.cochat.ai/papers/10.1118/1.4928676
- The paper
- Sechopoulos, I., Ali, E. S. M., Badal, A., Badano, A., Boone, J. M., Kyprianou, I. S., Mainegra‐Hing, E., McMillan, K. L., McNitt‐Gray, M. F., Rogers, D. W. O., Samei, E., & Turner, A. C. (2015). Monte Carlo reference data sets for imaging research: Executive summary of the report of AAPM Research Committee Task Group 195. Medical Physics. https://doi.org/10.1118/1.4928676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.