The DOI matches its Crossref record.
X‐ray imaging using amorphous selenium: Feasibility of a flat panel self‐scanned detector for digital radiology
Abstract
We investigate a concept for making a large area, flat‐panel detector for digital radiology. It employs an x‐ray sensitive photoconductor to convert incident x‐radiation to a charge image which is then electronically read out with a large area integrated circuit. The large area integrated circuit, also called an active matrix, consists of a two‐dimensional array of thin film transistors (TFTs). The potential advantages of the flat‐panel detector for digital radiography include: instantaneous digital radiographs without operator intervention; compact size approaching that of a screen‐film cassette and thus compatibility with existing x‐ray equipment; high quantum efficiency combined with high resolution. Its potential advantages over the x‐ray image intensifier (XRII)/video systems for fluoroscopy include: compactness; geometric accuracy; high resolution, and absence of veiling glare. The feasibility of the detector for digital radiology was investigated using the properties of a particular photoconductor (amorphous selenium) and active matrix array (with cadmium selenide TFTs). The results showed that it can potentially satisfy the detector design requirements for radiography (e.g., chest radiography and mammography). For fluoroscopy, the images can be obtained in real‐time but the detector is not quantum noise limited below the mean exposure rate typically used in fluoroscopy. Possible improvements in x‐ray sensitivity and noise performance for the application in fluoroscopy are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of X-ray photons by solution-processed lead halide perovskites
Yakunin, S., Sytnyk, M., Kriegner, D., Shrestha, S., Richter, M., Matt, G. J., Azimi, H., Brabec, C. J., Stangl, J., Kovalenko, M. V., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.82 · Cited by 1,184
Wei, W., Zhang, Y., Xu, Q., Wei, H., Fang, Y., Wang, Q., Deng, Y., Li, T., Gruverman, A., Cao, L., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.43 · Cited by 814
Zhuang, R., Wang, X., Ma, W., Wu, Y., Chen, X., Tang, L., Zhu, H., Liu, J., Wu, L., Zhou, W., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0466-7 · Cited by 630
Doi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 290
Metal Halide Perovskites for High‐Energy Radiation Detection
Kakavelakis, G., Gedda, M., Panagiotopoulos, A., Kymakis, E., Anthopoulos, T. D., & Petridis, K. (2020) · Advanced Science · doi:10.1002/advs.202002098 · Cited by 286
Digital pathology and computational image analysis in nephropathology
Barisoni, L., Lafata, K. J., Hewitt, S. M., Madabhushi, A., & Balis, U. G. J. (2020) · Nature Reviews Nephrology · doi:10.1038/s41581-020-0321-6 · Cited by 264
Shen, Y., Liu, Y., Ye, H., Zheng, Y., Wei, Q., Xia, Y., Chen, Y., Zhao, K., Huang, W., & Liu, S. (. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202004160 · Cited by 254
Metadata
- Authors
- Zhao, W., & Rowlands, J. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1995-10
- Volume
- 22
- Issue
- 10
- Pages
- 1595-1604
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2156256714
- Cited by
- 322
- References
- 0
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.