Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysis

Open access
Sahiner, Berkman, Chan, Heang-Ping, Petrick, Nicholas, Helvie, Mark A., Goodsitt, Mitchell M.·1998·Medical Physics

Abstract

A new rubber band straightening transform (RBST) is introduced for characterization of mammographic masses as malignant or benign. The RBST transforms a band of pixels surrounding a segmented mass onto the Cartesian plane (the RBST image). The border of a mammographic mass appears approximately as a horizontal line, and possible speculations resemble vertical lines in the RBST image. In this study, the effectiveness of a set of directional textures extracted from the images before the RBST. A database of 168 mammograms containing biopsy-proven malignant and benign breast masses was digitized at a pixel size of 100 microns x 100 microns. Regions of interest (ROIs) containing the biopsied mass were extracted from each mammogram by an experienced radiologist. A clustering algorithm was employed for automated segmentation of each ROI into a mass object and background tissue. Texture features extracted from spatial gray-level dependence matrices and run-length statistics matrices were evaluated for three different regions and representations: (i) the entire ROI; (ii) a band of pixels surrounding the segmented mass object in the ROI; and (iii) the RBST image. Linear discriminant analysis was used for classification, and receiver operating characteristic (ROC) analysis was used to evaluate the classification accuracy. Using the ROC curves as the performance measure, features extracted from the RBST images were found to be significantly more effective than those extracted from the original images. Features extracted from the RBST images yielded an area (Az) of 0.94 under the ROC curve for classification of mammographic masses as malignant and benign.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.598228

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 205

Metadata

Authors
Sahiner, B., Chan, H.-P., Petrick, N., Helvie, M. A., & Goodsitt, M. M.
Venue
Medical Physics
Publisher
Wiley
Published
1998-04
Volume
25
Issue
4
Pages
516-526
ISSN
0094-2405 (ISSN-L)
OpenAlex
W2054470248
Cited by
205
References
1
FWCI
8.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysis. https://app.cochat.ai/papers/10.1118/1.598228
The paper
Sahiner, B., Chan, H.-P., Petrick, N., Helvie, M. A., & Goodsitt, M. M. (1998). Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysis. Medical Physics. https://doi.org/10.1118/1.598228

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.