CoChat

Computer‐aided diagnosis: Automatic detection of malignant masses in digitized mammograms

Méndez, Arturo J., Tahoces, Pablo G., Lado, Marı́a J., Souto, Miguel, Vidal, Juan J. · 1998 · Medical Physics
Cited by 138

The DOI matches its Crossref record.

Abstract

A computerized method to automatically detect malignant masses on digital mammograms based on bilateral subtraction to identify asymmetries between left and right breast images was developed. After the digitization, in order to align left and right mammograms the breast border and nipple were automatically detected. Images were corrected to avoid differences in brightness due to the recording procedure. Left and right mammograms were subtracted and a threshold was applied to obtain a binary image with the information of suspicious areas. The suspicious regions or asymmetries were delimited by a region growing algorithm. Size and eccentricity tests were used to eliminate false‐positive responses and texture features were extracted from suspicious regions to reject normal tissue regions. The scheme, tested in 70 pairs of digital mammograms, achieved a true‐positive rate of 71% with an average number of 0.67 false positives per image. Computerized detection was evaluated by using free‐response operating characteristic analysis (FROC). An area under the AFROC of 0.667 was obtained. Our results show that the scheme may be helpful to the radiologists by serving as a second reader in mammographic screening. The low number of false positives indicates that our scheme would not confuse the radiologist by suggesting normal regions as suspicious.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.598274

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 138

Metadata

Authors
Méndez, A. J., Tahoces, P. G., Lado, M. J., Souto, M., & Vidal, J. J.
Venue
Medical Physics
Publisher
Wiley
Published
1998-06
Volume
25
Issue
6
Pages
957-964
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2063322980
Cited by
138
References
0
FWCI
7.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computer‐aided diagnosis: Automatic detection of malignant masses in digitized mammograms. https://app.cochat.ai/papers/10.1118/1.598274
The paper
Méndez, A. J., Tahoces, P. G., Lado, M. J., Souto, M., & Vidal, J. J. (1998). Computer‐aided diagnosis: Automatic detection of malignant masses in digitized mammograms. Medical Physics. https://doi.org/10.1118/1.598274

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.