Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 651

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Measuring Computed Tomography Scanner Variability of Radiomics Features

Open access
Mackin, Dennis, Fave, Xenia, Zhang, Lifei, Fried, David, Yang, Jinzhong, Taylor, Brian, Rodriguez-Rivera, Edgardo, Dodge, Cristina, Jones, Aaron Kyle, Court, Laurence · 2015 · Investigative Radiology

Abstract

OBJECTIVES: The purpose of this study was to determine the significance of interscanner variability in CT image radiomics studies. MATERIALS AND METHODS: We compared the radiomics features calculated for non-small cell lung cancer (NSCLC) tumors from 20 patients with those calculated for 17 scans of a specially designed radiomics phantom. The phantom comprised 10 cartridges, each filled with different materials to produce a wide range of radiomics feature values. The scans were acquired using General Electric, Philips, Siemens, and Toshiba scanners from 4 medical centers using their routine thoracic imaging protocol. The radiomics feature studied included the mean and standard deviations of the CT numbers as well as textures derived from the neighborhood gray-tone difference matrix. To quantify the significance of the interscanner variability, we introduced the metric feature noise. To look for patterns in the scans, we performed hierarchical clustering for each cartridge. RESULTS: The mean CT numbers for the 17 CT scans of the phantom cartridges spanned from -864 to 652 Hounsfield units compared with a span of -186 to 35 Hounsfield units for the CT scans of the NSCLC tumors, showing that the phantom's dynamic range includes that of the tumors. The interscanner variability of the feature values depended on both the cartridge material and the feature, and the variability was large relative to the interpatient variability in the NSCLC tumors for some features. The feature interscanner noise was greatest for busyness and least for texture strength. Hierarchical clustering produced different clusters of the phantom scans for each cartridge, although there was some consistent clustering by scanner manufacturer. CONCLUSIONS: The variability in the values of radiomics features calculated on CT images from different CT scanners can be comparable to the variability in these features found in CT images of NSCLC tumors. These interscanner differences should be considered, and their effects should be minimized in future radiomics studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0000000000000180

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 651

Metadata

Authors
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L.
Venue
Investigative Radiology
Published
2015-11
Volume
50
Issue
11
Pages
757-765
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2398056625
Cited by
651
References
27
FWCI
28.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measuring Computed Tomography Scanner Variability of Radiomics Features. https://app.cochat.ai/papers/10.1097/rli.0000000000000180
The paper
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015). Measuring Computed Tomography Scanner Variability of Radiomics Features. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000180

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.