Electrodynamic headphones and woofers for application in magnetic resonance imaging scanners
The DOI matches its Crossref record.
Abstract
Electrodynamic speakers compatible with (functional) magnetic resonance imaging (MRI) are described. The speakers magnets are removed, their function is replaced by the scanner's magnetic field, resulting in an uncommon but efficient operation. The method can be used with headphones as well as woofers. Functional MRI is not associated with any known biological risks, but as a method for visualization of task‐specific activation of brain regions it is undesirably noisy. Thus, it requires both noise protection and efficient sound transmission systems for delivering acoustic stimuli to subjects. Woofers could possibly be used in active noise‐control systems. The speakers described in this paper can be used for either task.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Study design in fMRI: Basic principles
Amaro, E., & Barker, G. J. (2006) · Brain and Cognition · doi:10.1016/j.bandc.2005.11.009 · Cited by 517
Regulation of emotional responses elicited by threat-related stimuli
Eippert, F., Veit, R., Weiskopf, N., Erb, M., Birbaumer, N., & Anders, S. (2007) · Human Brain Mapping · doi:10.1002/hbm.20291 · Cited by 419
“A startle probe (a 50 ms white noise burst, loudness adjusted individually to reliably elicit startle eyeblinks and to be unpleasant but not painful) was presented through headphones (HD 570, Sennheiser, Germany; modified after Baumgart et al. [1998] ) at 2 s into the regulation phase.”
MethodBrain activity underlying emotional valence and arousal: a response-related fMRI study
Anders, S., Lotze, M., Erb, M., Grodd, W., & Birbaumer, N. (2004) · Human Brain Mapping · doi:10.1002/hbm.20048 · Cited by 341
Identification of emotional intonation evaluated by fMRI
Wildgruber, D., Riecker, A., Hertrich, I., Erb, M., Grodd, W., Ethofer, T., & Ackermann, H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.034 · Cited by 336
Functional Imaging Reveals Numerous Fields in the Monkey Auditory Cortex
Petkov, C. I., Kayser, C., Augath, M., & Logothetis, N. K. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040215 · Cited by 235
“The headphones are composed of an electrodynamic membrane [45] within customized and foam insulated headphone cups, customized for use with these monkeys.”
Method
Metadata
- Authors
- Baumgart, F., Kaulisch, T., Tempelmann, C., Gaschler‐Markefski, B., Tegeler, C., Schindler, F., Stiller, D., & Scheich, H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1998-10
- Volume
- 25
- Issue
- 10
- Pages
- 2068-2070
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1974520217
- Cited by
- 114
- References
- 0
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrodynamic headphones and woofers for application in magnetic resonance imaging scanners. https://app.cochat.ai/papers/10.1118/1.598368
- The paper
- Baumgart, F., Kaulisch, T., Tempelmann, C., Gaschler‐Markefski, B., Tegeler, C., Schindler, F., Stiller, D., & Scheich, H. (1998). Electrodynamic headphones and woofers for application in magnetic resonance imaging scanners. Medical Physics. https://doi.org/10.1118/1.598368
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.