CoChat

Registration and warping of magnetic resonance images to histological sections

Jacobs, Michael A., Windham, Joe P., Soltanian-Zadeh, Hamid, Peck, Donald J., Knight, Robert A. · 1999 · Medical Physics
Cited by 102

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We present a method for coregistration and warping of magnetic resonance images (MRI) to histological sections for comparison purposes. This methodology consists of a modified head and hat surface-based registration algorithm followed by a new automated warping approach using nonlinear thin plate splines to compensate for distortions between the data sets. To test the methodology, 15 male Wistar rats were subjected to focal cerebral ischemia via permanent occlusion of the middle cerebral artery. The MRI images were acquired in separate groups of animals at 16-24 h (n = 9) and 48-168 h (n = 6) postocclusion. After imaging, animals were immediately sacrificed and hematoxylin- and eosin-stained brain sections were obtained for histological analysis. The MRI was coregistered and warped to histological sections. The MRI lesion areas were defined using the Eigenimage (EI) filter technique. The EI is a linear filter that maximizes the projection of a desired tissue (ischemic tissue) while it minimizes the projection of undesired tissues (nonischemic tissue) onto a composite image called an EI. When using coregistration without warping the MRI lesion area demonstrated poor correlation (r = 0.55, p > 0.01) with a percent difference between the two lesion areas of 22.5% +/- 10.8%. After warping, the MRI and histology had significant correlation (r = 0.97, p < 0.01) and a decreased percent difference of 5.56% +/- 4.31%. This methodology is simple and robust for coregistration and warping of MRI to histological sections and can be utilized in many applications for comparison of MRI to histological data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.598671

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 102

Metadata

Authors
Jacobs, M. A., Windham, J. P., Soltanian-Zadeh, H., Peck, D. J., & Knight, R. A.
Venue
Medical Physics
Publisher
Wiley
Published
1999-08
Volume
26
Issue
8
Pages
1568-1578
ISSN
0094-2405 (ISSN-L)
OpenAlex
W2083453707
Cited by
102
References
2
FWCI
3.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Registration and warping of magnetic resonance images to histological sections. https://app.cochat.ai/papers/10.1118/1.598671
The paper
Jacobs, M. A., Windham, J. P., Soltanian-Zadeh, H., Peck, D. J., & Knight, R. A. (1999). Registration and warping of magnetic resonance images to histological sections. Medical Physics. https://doi.org/10.1118/1.598671

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.