A human nonlinear cochlear filterbank
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Some published cochlear filterbanks are nonlinear but are fitted to animal basilar membrane (BM) responses. Others, like the gammatone, are based on human psychophysical data, but are linear. In this article, a human nonlinear filterbank is constructed by adapting a computational model of animal BM physiology to simulate human BM nonlinearity as measured by psychophysical pulsation-threshold experiments. The approach is based on a dual-resonance nonlinear type of filter whose basic structure was modeled using animal observations. In modeling the pulsation threshold data, the main assumption is that pulsation threshold occurs when the signal and the masker produce comparable excitation, that is the same filter output, at the place of the BM best tuned to the signal frequency. The filter is fitted at a discrete number of best frequencies (BFs) for which psychophysical data are available for a single listener and for an average response of six listeners. The filterbank is then created by linear regression of the resulting parameters to intermediate BFs. The strengths and limitations of the resulting filterbank are discussed. Its suitability for simulating hearing-impaired cochlear responses is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Derivation of auditory filter shapes from notched-noise data
Glasberg, B. R., & Moore, B. C. J. (1990) · Hearing Research · doi:10.1016/0378-5955(90)90170-t · Cited by 2,423
Basilar-membrane responses to tones at the base of the chinchilla cochlea
Ruggero, M. A., Rich, N. C., Recio, A., Narayan, S. S., & Robles, L. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.418265 · Cited by 781
Cochlear Hearing Loss: Physiological, Psychological and Technical Issues
Moore, B. C. J. (2007) · Wiley eBooks · doi:10.1002/9780470987889 · Cited by 445
A computational model of filtering, detection, and compression in the cochlea
Lyon, R. (2005) · ICASSP '82. IEEE International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1982.1171644 · Cited by 411 · cited 1×
“…hearing lo Historically, the computations have used banks of lin gammatone filters~Pattersonet al., 1992! but more recently researchers have attempted to use nonlinear filters~Giguère and Woodland, 1994; Lyon, 1982; Carney, 1993; Goldste 1990, 1995; Lopez-Povedaet al., 1998; Meddiset al., 2001!.”
MethodAn Efficient Implementation of the Patterson-Holdsworth Auditory Filter Bank
Slaney, M. (1997) · Cited by 409
Basilar membrane measurements and the travelling wave
Johnstone, B. M., Patuzzi, R. B., & Yates, G. K. (1986) · Hearing Research · doi:10.1016/0378-5955(86)90090-0 · Cited by 334 · cited 1×
“Sim notches have been consistently observed in physiolog measurements of the cochlear partition in chinchilla~e.g., Rhode and Recio, 2000! and may be the explanation fo ‘‘Nelson’s notches’’~Kiang et al., 1986, Fig.”
BackgroundA behavioral measure of basilar-membrane nonlinearity in listeners with normal and impaired hearing
Oxenham, A. J., & Plack, C. J. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.418327 · Cited by 273
Psychophysical Evidence for Lateral Inhibition in Hearing
Houtgast, T. (1972) · The Journal of the Acoustical Society of America · doi:10.1121/1.1913048 · Cited by 265
Ruggero, M. A., Robles, L., & Rich, N. C. (1992) · Journal of Neurophysiology · doi:10.1152/jn.1992.68.4.1087 · Cited by 262
A model for the responses of low-frequency auditory-nerve fibers in cat
Carney, L. H. (1993) · The Journal of the Acoustical Society of America · doi:10.1121/1.405620 · Cited by 236
Yates, G. K., Winter, I. M., & Robertson, D. (1990) · Hearing Research · doi:10.1016/0378-5955(90)90121-5 · Cited by 232
Transfer characteristics of headphones measured on human ears
Møller, H., Hammershøi, D., Jensen, C. B., et al. (1995) · VBN Forskningsportal (Aalborg Universitet) · Cited by 128
Single unit clues to cochlear mechanisms
Klang, N. Y. S., Liberman, M. C., Sewell, W. F., & Guinan, J. J. (1986) · Hearing Research · doi:10.1016/0378-5955(86)90093-6 · Cited by 110
Pralong, D., & Carlile, S. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417337 · Cited by 93 · cited 1×
“A typical human headphone-to eardrum sound pressure gain~from Pralong and Carlile, 1996, Fig.”
Background
Cited by
Cochlear Implants: Some Likely Next Steps
Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121645 · Cited by 160
Autoencoding sensory substitution
Tóth, V., & Parkkonen, L. (2019) · Unpublished · doi:10.13140/rg.2.2.10576.87048 · Cited by 7
“by traveling waves on BM, and simultaneous, forward and backward masking [106], among others.”
BackgroundMethodInfluential
Metadata
- Authors
- Lopez-Poveda, E. A., & Meddis, R.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2001-12-01
- Volume
- 110
- Issue
- 6
- Pages
- 3107-3118
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2004930422
- Cited by
- 220
- References
- 14
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.