The reflection of the fundamental torsional mode from cracks and notches in pipes
Abstract
A quantitative study of the reflection of the T(0,1) mode from defects in pipes in the frequency range 10–300 kHz has been carried out, finite element predictions being validated by experiments on selected cases. Both cracklike defects with zero axial extent and notches with varying axial extents have been considered. The results show that the reflection coefficient from axisymmetric cracks increases monotonically with depth at all frequencies and increases with frequency at any given depth. In the frequency range of interest there is no mode conversion at axisymmetric defects. With nonaxisymmetric cracks, the reflection coefficient is a roughly linear function of the circumferential extent of the defect at relatively high frequencies, the reflection coefficient at low circumferential extents falling below the linear prediction at lower frequencies. With nonaxisymmetric defects, mode conversion to the F(1,2) mode is generally seen, and at lower frequencies the F(1,3) mode is also produced. The depth and circumferential extent are the parameters controlling the reflection from cracks; when notches having finite axial extent, rather than cracks, are considered, interference between the reflections from the start and the end of the notch causes a periodic variation of the reflection coefficient as a function of the axial extent of the notch. The results have been explained in terms of the wave-number-defect size product, ka. Low frequency scattering behavior is seen when ka<0.1, high frequency scattering characteristics being seen when ka>1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic Fields and Waves in Solids
Auld, B. A. (1973) · Medical Entomology and Zoology · Cited by 5,827
Acoustic waves : devices, imaging, and analog signal processing
Kino, G. S. (1987) · Prentice Hall eBooks · Cited by 1,277
The interaction of Lamb waves with defects
Alleyne, D. N., & Cawley, P. (1992) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.143172 · Cited by 997
Self-citationThe excitation of Lamb waves in pipes using dry-coupled piezoelectric transducers
Alleyne, D. N., & Cawley, P. (1996) · Journal of Nondestructive Evaluation · doi:10.1007/bf00733822 · Cited by 227
Self-citationOn Inspection of Thin-Walled Tubes for Transverse and Longitudinal Flaws by Guided Ultrasonic Waves
Mohr, W., & Höller, P. (1976) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1976.30893 · Cited by 108
Cited by
Demma, A., Cawley, P., Lowe, M., Roosenbrand, A. G., & Pavlakovic, B. (2004) · NDT & E International · doi:10.1016/j.ndteint.2003.09.004 · Cited by 283
Self-citationMiao, H., & Li, F. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106355 · Cited by 268
Ismail, Z., Mustapha, S., & Tarhini, H. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106523 · Cited by 16
Metadata
- Authors
- Demma, A., Cawley, P., Lowe, M., & Roosenbrand, A. G.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2003-07-30
- Volume
- 114
- Issue
- 2
- Pages
- 611-625
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2088141143
- Cited by
- 279
- References
- 5
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.