Vibrotactile transduction and transducers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The body’s sense of touch is potentially a versatile channel for the conveyance of directional, spatial, command, and timing information. Most practical implementations of vibrotactile systems require compact, light-weight actuators that can be mounted against the body. Eccentric mass motors are widely used for this application, yet their output is limited and the effects of loading on the transducers due to the skin and mounting arrangement have been largely ignored. Conventional linear actuators are well suited as vibrotactile transducers and can provide high output, but are typically limited to laboratory research due to their large size and cost. The effect of loading on various practical vibrotactile transducers is investigated using a skin impedance phantom and measuring the transducer displacement with respect to additional mass loading. Depending on the transducer design, loading can dramatically reduce the vibratory displacement and, in the case of eccentric mass motors, also increase the operating frequency. In contrast, a new linear actuator design can be designed to be almost independent of skin loading, by considering the mechanical impedance of the load and optimizing the transducer contact area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937
Cited by
Vibrotactile Display: Perception, Technology, and Applications
Choi, S., & Kuchenbecker, K. J. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2221071 · Cited by 496
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Investigating the effectiveness of tactile feedback for mobile touchscreens
Hoggan, E., Brewster, S. A., & Johnston, J. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357300 · Cited by 443
Closed-Loop Haptic Feedback Control Using a Self-Sensing Soft Pneumatic Actuator Skin
Sonar, H. A., Gerratt, A. P., Lacour, S. P., & Paik, J. (2020) · Soft Robotics · doi:10.1089/soro.2019.0013 · Cited by 159
“vibration amplitude decreases above 30 Hz, it is still measurable and perceivable to the human 8 skin for the frequencies up to 100 Hz (Figure 2f).([35]) The measurement system can measure the 9 resistance of sensor dynamically with accuracy of 0.”
(2018) · Springer Series on Touch and Haptic Systems · doi:10.1007/978-3-319-58316-7 · Cited by 60
Metadata
- Authors
- Mortimer, B. J. P., Zets, G. A., & Cholewiak, R. W.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2007-05-01
- Volume
- 121
- Issue
- 5
- Pages
- 2970-2977
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2056892835
- Cited by
- 92
- References
- 1
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibrotactile transduction and transducers. https://app.cochat.ai/papers/10.1121/1.2715669
- The paper
- Mortimer, B. J. P., Zets, G. A., & Cholewiak, R. W. (2007). Vibrotactile transduction and transducers. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.2715669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.