In-situ measures of user’s preferred listening levels with a portable digital music device.
The DOI matches its Crossref record.
Abstract
The recent development and popular use of personally worn digital music devices (PDMDs) have led to concerns about the intensity levels they produce. There is concern that users will set a PDMD to levels that are known to be hazardous to human hearing. The concern stems from the private nature of a PDMD in that insert earphones are worn that restrict the output to the user’s ears, thus prohibiting monitoring of such devices by parents, teachers, employers, etc. This project measured the in-situ dB SPL produced by PDMDs worn by 31 young adults (18–23 years) who had been wearing PDMDs for 3 years or less. Subjects set their PDMD to their preferred listening level (PLL) for a popular tune. Once set, in-situ SPL measures of the tune at a reference point and then for a white noise were obtained with a probe microphone located near the eardrum. Hearing thresholds were also obtained. Results showed a range of 52–107 dB with a mean PLL of 83 dB for music and a range of 53–99 dB with a mean PLL of 79 dB for white noise. None of the subjects had significant hearing loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Goshorn [65] reported that 35.5% of participants had tinnitus despite normal pure-tone audiometry”
From Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis (2026) · cites this paper as [65]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis
Golshaniniya, P., PorkarKhatibi, M., Rouhi, A. J., Moghaddam, Y. J., Zabet, S., Salehi-Pourmehr, H., & Shahsavarinia, K. (2026) · BMC Public Health · doi:10.1186/s12889-026-29110-5
Metadata
- Authors
- Goshorn, E. L., White, K. J., & Kemker, B. E.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2009-10-01
- Volume
- 126
- Issue
- 4_Supplement
- Pages
- 2219-2219
- ISSN
- 0001-4966
- 1520-8524
- Cited by
- 1
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.