The DOI matches its Crossref record.
Speech discrimination in deaf subjects with cochlear implants
Abstract
Electrical stimulation of the auditory nerve is being investigated as a way to provide information useful for speech communication in the profoundly deaf. Single-channel systems that tend to stimulate all fibers alike have had little success in achieving this goal. Multichannel systems that allow excitation of more complex temporal–spatial patterns of activity are now being introduced. Psychoacoustical experiments providing evidence that electrodes of a multichannel implant are able to separately excite distinct groups of neural elements are reviewed. New results using multiple electrodes and speech-like stimuli are presented. The synthetic stimuli were vowels (/a/, /i/, /u/) and consonant–vowel (CV) syllables (/ba/, /da/, /ga/, /ta/). Vowels and CV syllables were presented in an AXB discrimination task with different signal processing schemes and electrode configurations. A four-channel, frequency-selective system produced faultless discrimination scores for all stimuli and spontaneous recognition of the vowels while the scores for the single-channel system were generally much lower. Although understanding free running speech by the profoundly deaf does not seem imminent, the results presented indicate that the multichannel system tested shows more promise of approaching this goal than the single-channel scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Self-citationCochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Language Development in Profoundly Deaf Children with Cochlear Implants
Svirsky, M. A., Robbins, A. M., Kirk, K. I., Pisoni, D. B., & Miyamoto, R. T. (2000) · Psychological Science · doi:10.1111/1467-9280.00231 · Cited by 647
Music Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 549
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Loizou, P. C. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.708543 · Cited by 326
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea
Hartmann, R., Topp, G., & Klinke, R. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90094-7 · Cited by 298
History of Cochlear Implants and Auditory Brainstem Implants
Møller, A. R. (2006) · Advances in Oto-Rhino-Laryngology · doi:10.1159/000094455 · Cited by 37
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
Metadata
- Authors
- Eddington, D. K.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1980-09-01
- Volume
- 68
- Issue
- 3
- Pages
- 885-891
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2034141852
- Cited by
- 186
- References
- 0
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.