The DOI matches its Crossref record.
Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays
Abstract
The data acquisition rate in medical ultrasonic imaging devices is limited by the acoustic propagation velocity in the tissues. Typically in such machines the image lines are produced sequentially one line per transmitted pulse. A parallel processing scheme has been implemented which enables the data acquisition rate to increase by a factor of four through the simultaneous acquisition of four B-mode image lines from each individual broadened transmit pulse. The higher data rate can be used to increase the image frame rate to produce independent images that can be averaged in the image frame to reduce noise, or to produce a conventional image at standard video frame rates while reducing patient exposure. Alternatively, the field of view can be increased over that of a normal scan without sacrificing frame rate. These advantages are achieved with little reduction in the measured resolution. The design and performance of this device are described. A sample in vivo image is included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Metadata
- Authors
- Shattuck, D. P., Weinshenker, M. D., Smith, S. W., & von Ramm, O. T.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1984-04-01
- Volume
- 75
- Issue
- 4
- Pages
- 1273-1282
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2088463844
- Cited by
- 395
- References
- 0
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays. https://app.cochat.ai/papers/10.1121/1.390734
- The paper
- Shattuck, D. P., Weinshenker, M. D., Smith, S. W., & von Ramm, O. T. (1984). Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.390734
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.