The DOI matches its Crossref record.
Gap detection and masking in hearing-impaired and normal-hearing subjects
Abstract
Subjects with cochlear impairments often show reduced temporal resolution as measured in gap-detection tasks. The primary goals of these experiments were: (1) to assess the extent to which the enlarged gap thresholds can be explained by elevations in absolute threshold; and (2) to determine whether the large gap thresholds can be explained by the same processes that lead to a slower-than-normal recovery from forward masking. In experiment I gap thresholds were measured for nine unilaterally and eight bilaterally impaired subjects, using bandlimited noise stimuli centered at 0.5, 1.0, and 2.0 kHz. Gap thresholds were usually larger for the impaired ears, even when the comparisons were made at equal sensation levels (SLs). Gap thresholds tended to increase with increasing absolute threshold, but the scatter of gap thresholds was large for a given degree of hearing loss. In experiment II threshold was measured as a function of the delay between the onset of a 210-ms masker and the onset of a 10-ms signal in both simultaneous- and forward-masking conditions. The signal frequency was equal to the center frequency of the bandlimited noise masker, which was 0.5, 1.0, or 2.0 kHz. Five subjects with unilateral cochlear impairments, two subjects with bilateral impairments, and two normal subjects were tested. The rate of recovery from forward masking, particularly the initial rate, was usually slower for the impaired ears, even when the maskers were presented at equal SLs. Large gap thresholds tended to be associated with slow rates of recovery from forward masking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Syka, J. (2002) · Physiological Reviews · doi:10.1152/physrev.00002.2002 · Cited by 369
Speech‐in‐noise perception in high‐functioning individuals with autism or Asperger's syndrome
Alcántara, J. I., Weisblatt, E. J. L., Moore, B. C. J., & Bolton, P. F. (2004) · Journal of Child Psychology and Psychiatry · doi:10.1111/j.1469-7610.2004.t01-1-00303.x · Cited by 321
Self-citationPeters, R. W., Moore, B. C. J., & Baer, T. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.421128 · Cited by 315
Self-citationMoore, B. C. J. (1996) · Ear and Hearing · doi:10.1097/00003446-199604000-00007 · Cited by 273
Self-citation5XFAD Mice Show Early Onset Gap Detection Deficits
Kaylegian, K., Stebritz, A. J., Weible, A. P., & Wehr, M. (2019) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2019.00066 · Cited by 20
Metadata
- Authors
- Glasberg, B. R., Moore, B. C. J., & Bacon, S. P.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1987-05-01
- Volume
- 81
- Issue
- 5
- Pages
- 1546-1556
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2084006136
- Cited by
- 170
- References
- 0
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gap detection and masking in hearing-impaired and normal-hearing subjects. https://app.cochat.ai/papers/10.1121/1.394507
- The paper
- Glasberg, B. R., Moore, B. C. J., & Bacon, S. P. (1987). Gap detection and masking in hearing-impaired and normal-hearing subjects. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.394507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.