Information from time-varying vibrotactile stimuli
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Experiments have been carried out to investigate the information transfer available via a single vibrator on the fingertip. In a first experiment, for stimuli with durations 80 to 320 ms, discrimination of a one-octave step change in frequency at the halfway point was investigated. Results were similar for three stimulus types—sinewave, monophasic pulse and tetraphasic pulse—suggesting temporal cues are more important than spectral cues in this task. In a second experiment, subjects were required to perceive changes in a sequence of stimulus elements. A presentation rate of 6.25 elements s−1 was found to give better results than a rate of 12.5 elements s−1. In the former case, the potential information transfer per element was estimated to be approximately 1.0 bits, corresponding to an information transfer rate of around 6 bits s−1. Implications for the design of a tactile aid to lipreading are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937
The Information Capacity of the Human Fingertip
Kokjer, K. (1987) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/tsmc.1987.289337 · Cited by 61
Cited by
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 561
Information transmission with a multifinger tactual display
Tan, H. Z., Durlach, N. I., Reed, C. M., & Rabinowitz, W. M. (1999) · Perception & Psychophysics · doi:10.3758/bf03207608 · Cited by 159
Novich, S. D., & Eagleman, D. M. (2015) · Experimental Brain Research · doi:10.1007/s00221-015-4346-1 · Cited by 148
Effect of Waveform on Tactile Perception by Electrovibration Displayed on Touch Screens
Vardar, Y., Guclu, B., & Basdogan, C. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2704603 · Cited by 130
“[53], observed that vibrotactile sine waves and monophasic/tetra-phasic pulses at suprathreshold levels resulted in similar scores in a”
Result
Metadata
- Authors
- Summers, I. R., Cooper, P. G., Wright, P., Gratton, D. A., Milnes, P., & Brown, B. H.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1997-12-01
- Volume
- 102
- Issue
- 6
- Pages
- 3686-3696
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2014641393
- Cited by
- 49
- References
- 2
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Information from time-varying vibrotactile stimuli. https://app.cochat.ai/papers/10.1121/1.420154
- The paper
- Summers, I. R., Cooper, P. G., Wright, P., Gratton, D. A., Milnes, P., & Brown, B. H. (1997). Information from time-varying vibrotactile stimuli. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.420154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.