Human interaural time difference thresholds for sine tones: The high-frequency limit
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
The smallest detectable interaural time difference (ITD) for sine tones was measured for four human listeners to determine the dependence on tone frequency. At low frequencies, 250–700 Hz, threshold ITDs were approximately inversely proportional to tone frequency. At mid-frequencies, 700–1000 Hz, threshold ITDs were smallest. At high frequencies, above 1000 Hz, thresholds increased faster than exponentially with increasing frequency becoming unmeasurably high just above 1400 Hz. A model for ITD detection began with a biophysically based computational model for a medial superior olive (MSO) neuron that produced robust ITD responses up to 1000 Hz, and demonstrated a dramatic reduction in ITD-dependence from 1000 to 1500 Hz. Rate-ITD functions from the MSO model became inputs to binaural display models—both place based and rate-difference based. A place-based, centroid model with a rigid internal threshold reproduced almost all features of the human data. A signal-detection version of this model reproduced the high-frequency divergence but badly underestimated low-frequency thresholds. A rate-difference model incorporating fast contralateral inhibition reproduced the major features of the human threshold data except for the divergence. A combined, hybrid model could reproduce all the threshold data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,477 · cited 1×
“The experiment used a three-down, one-up adaptive staircase procedure (Levitt, 1971), estimating the 79.4% correct point on a psychometric function.”
MethodInfluentialA place theory of sound localization.
Jeffress, L. A. (1948) · Journal of Comparative and Physiological Psychology · doi:10.1037/h0061495 · Cited by 1,480 · cited 1×
“The centroid model is a particular example of a place model (Jeffress, 1948); the rate-difference model minimizes the role of place encoding and relies on the difference in firing rates in left and right sides of the binaural system (McAlpine et al., 2001).”
BackgroundGoldberg, J. M., & Brown, P. B. (1969) · Journal of Neurophysiology · doi:10.1152/jn.1969.32.4.613 · Cited by 1,469 · cited 2×
“Qp [RYL] Pages: 2839–2855 I. INTRODUCTION It is a well-known fact of binaural hearing that human listeners are not able to detect interaural time differences (ITDs) in sine tones with frequencies greater than about 1500 Hz.”
BackgroundMills, A. W. (1958) · The Journal of the Acoustical Society of America · doi:10.1121/1.1909553 · Cited by 964 · cited 1×
“Mills (1958) identified 1400 Hz as the upper limit for effective ITDs.”
BackgroundXII. On our perception of sound direction
Rayleigh, L. (1907) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440709463595 · Cited by 860
Interaural time sensitivity in medial superior olive of cat
Yin, T. C., & Chan, J. C. (1990) · Journal of Neurophysiology · doi:10.1152/jn.1990.64.2.465 · Cited by 729 · cited 2×
“Qp [RYL] Pages: 2839–2855 I. INTRODUCTION It is a well-known fact of binaural hearing that human listeners are not able to detect interaural time differences (ITDs) in sine tones with frequencies greater than about 1500 Hz.”
BackgroundPrecise inhibition is essential for microsecond interaural time difference coding
Brand, A., Behrend, O., Marquardt, T., McAlpine, D., & Grothe, B. (2002) · Nature · doi:10.1038/417543a · Cited by 571 · cited 1×
“In addition, to produce contralateral-leading best-ITDs similar to those measured in Brand et al. (2002), rapidly decaying inhibition was applied in separate simulations using sIrise ¼ 0:39996 ms and sIdecay ¼ 0:4 ms.”
MethodA neural code for low-frequency sound localization in mammals
McAlpine, D., Jiang, D., & Palmer, A. R. (2001) · Nature Neuroscience · doi:10.1038/86049 · Cited by 449 · cited 2×
“A combined, hybrid model could reproduce all the threshold data.”
BackgroundListener weighting of cues for lateral angle: The duplex theory of sound localization revisited
Macpherson, E. A., & Middlebrooks, J. C. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1471898 · Cited by 414
Rothman, J. S., & Manis, P. B. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00127.2002 · Cited by 281 · cited 1×
“…MSO neurons in Scott et al. (2010); for the hyperpolarization-activated cation (h), the equations for VCN neurons in guinea pig (Zhou et al., 2005; Rothman and Manis, 2003); and for low-threshold potassium (KLT), the equations for gerbil MSO neurons in Mathews et al. (2010) with one modification…”
BackgroundDetectability of interaural delay in high-frequency complex waveforms
Henning, G. B. (1974) · The Journal of the Acoustical Society of America · doi:10.1121/1.1928135 · Cited by 274
Theory of binaural interaction based on auditory-nerve data. II. Detection of tones in noise
Colburn, H. S. (1977) · The Journal of the Acoustical Society of America · doi:10.1121/1.381294 · Cited by 202 · cited 1×
“Although interaural differences in time and level both vary in realistic environments, the lowest ITD thresholds occur when there is no interaural level difference (ILD) (Domnitz and Colburn, 1977), and our goal was to obtain the lowest possible thresholds.”
BackgroundScott, L. L., Mathews, P. J., & Golding, N. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1016-05.2005 · Cited by 185 · cited 2×
“These sM values are in the faster range of measured somatic sM values in MSO neurons (Scott et al., 2005; Scott et al., 2007).”
BackgroundResultSivaramakrishnan, S., & Oliver, D. L. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-08-02861.2001 · Cited by 179
Stereausis: Binaural processing without neural delays
Shamma, S., Shen, N., & Gopalaswamy, P. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398734 · Cited by 176
Localization of sound in rooms, III: Onset and duration effects
Rakerd, B., & Hartmann, W. M. (1986) · The Journal of the Acoustical Society of America · doi:10.1121/1.394282 · Cited by 173 · cited 1×
“According to Rakerd and Hartmann (1986), 100 ms is adequate.”
BackgroundSelf-citationCharacterisation of inhibitory and excitatory postsynaptic currents of the rat medial superior olive
Smith, A. J., Owens, S., & Forsythe, I. D. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00681.x · Cited by 170 · cited 1×
“The four contralaterally-driven inhibitory inputs represent glycinergic inputs to the MSO neuron from the medial nucleus of the trapezoid body (Smith et al., 2000).”
BackgroundSmith, P. H. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.4.1653 · Cited by 168
Control of submillisecond synaptic timing in binaural coincidence detectors by Kv1 channels
Mathews, P. J., Jercog, P. E., Rinzel, J., Scott, L. L., & Golding, N. L. (2010) · Nature Neuroscience · doi:10.1038/nn.2530 · Cited by 165 · cited 5×
“…neurons in guinea pig (Zhou et al., 2005; Rothman and Manis, 2003); and for low-threshold potassium (KLT), the equations for gerbil MSO neurons in Mathews et al. (2010) with one modification for a faster inactivation (contained in the dynamics equations received courtesy of Fischl and…”
BackgroundMethodResultInfluentialMechanisms for Adjusting Interaural Time Differences to Achieve Binaural Coincidence Detection
Seidl, A. H., Rubel, E. W., & Harris, D. M. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3464-09.2010 · Cited by 162
Stern, R. M., & Colburn, H. S. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.381978 · Cited by 159
Maturation of glycinergic inhibition in the gerbil medial superior olive after hearing onset
Magnusson, A. K., Kapfer, C., Grothe, B., & Koch, U. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.094763 · Cited by 153
Shackleton, T. M., SKOTTUN, B. C., Arnott, R. H., & Palmer, A. R. (2003) · Journal of Neuroscience · doi:10.1523/jneurosci.23-02-00716.2003 · Cited by 114 · cited 1×
“Data from Shackleton et al. (2003) describe guinea pig IC recordings.”
BackgroundBatra, R., Kuwada, S., & Fitzpatrick, D. C. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.3.1237 · Cited by 111
Acoustic-Image Lateralization Judgments with Binaural Tones
Sayers, B. M. (1964) · The Journal of the Acoustical Society of America · doi:10.1121/1.1919121 · Cited by 104
The ability of inferior colliculus neurons to signal differences in interaural delay
SKOTTUN, B. C., Shackleton, T. M., Arnott, R. H., & Palmer, A. R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.241513998 · Cited by 90 · cited 1×
“Skottun et al. (2001) made similar arguments for point processes in the range where variability is frequency independent.”
BackgroundScott, L. L., Hage, T. A., & Golding, N. L. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.136366 · Cited by 90 · cited 1×
“These sM values are in the faster range of measured somatic sM values in MSO neurons (Scott et al., 2005; Scott et al., 2007).”
BackgroundStern, R. M., & Shear, G. D. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417937 · Cited by 81
Scott, L. L., Mathews, P. J., & Golding, N. L. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.2385-09.2010 · Cited by 72 · cited 3×
“The model MSO neuron is based on existing multicompartment Hodgkin-Huxley models for a principal MSO neuron and its ion-channel dynamics (Zhou et al., 2005; Scott et al., 2010; Mathews et al., 2010; Fischl et al., 2012) with modifications from the Zhou et al. (2005) model described below.”
BackgroundMethodInfluentialFischl, M. J., Combs, T. D., Klug, A., Grothe, B., & Burger, R. M. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.226233 · Cited by 40 · cited 2×
“Synaptic time constants were set according to measured values from MSO neurons (Fischl et al., 2012; Magnusson et al., 2005).”
MethodThe interaural time jnd as a simultaneous function of interaural time and interaural amplitude
Domnitz, R. H. (1973) · The Journal of the Acoustical Society of America · doi:10.1121/1.1913500 · Cited by 27 · cited 2×
“For example, Hershkowitz and Durlach (1969) and Domnitz (1973) used a method of constant stimuli and found the 75%-correct points on the psychometric functions.”
BackgroundMethod
Cited by
Virtual Sound Localization by Blind People
Dunai, L., Lengua, I., Peris-Fajarnés, G., & Brusola, F. (2015) · Archives of Acoustics · doi:10.1515/aoa-2015-0055 · Cited by 14
Self-citation
Metadata
- Authors
- Brughera, A., Dunai, L., & Hartmann, W. M.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2013-05-01
- Volume
- 133
- Issue
- 5
- Pages
- 2839-2855
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2041118149
- Cited by
- 206
- References
- 31
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.