The softest sound levels of the human voice in normal subjects
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Accurate measurement of the softest sound levels of phonation presents technical and methodological challenges. This study aimed at (1) reliably obtaining normative data on sustained softest sound levels for the vowel [a:] at comfortable pitch; (2) comparing the results for different frequency and time weighting methods; and (3) refining the Union of European Phoniatricians' recommendation on allowed background noise levels for scientific and equipment manufacturers' purposes. Eighty healthy untrained participants (40 females, 40 males) were investigated in quiet rooms using a head-mounted microphone and a sound level meter at 30 cm distance. The one-second-equivalent sound levels were more stable and more representative for evaluating the softest sustained phonations than the fast-time-weighted levels. At 30 cm, these levels were in the range of 48−61 dB(C)/41−53 dB(A) for females and 49 − 64 dB(C)/35−53 dB(A) for males (5% to 95% quantile range). These ranges may serve as reference data in evaluating vocal normality. In order to reach a signal-to-noise ratio of at least 10 dB for more than 95% of the normal population, the background noise should be below 25 dB(A) and 38 dB(C), respectively, for the softest phonation measurements at 30 cm distance. For the A-weighting, this is 15 dB lower than the previously recommended value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Voice Handicap Index (VHI): Development and Validation
Jacobson, B. H., Johnson, A., Grywalski, C., Silbergleit, A., Jacobson, G., Benninger, M. S., & Newman, C. W. (1997) · American Journal of Speech-Language Pathology · doi:10.1044/1058-0360.0603.66 · Cited by 2,574
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationAn ultrathin conformable vibration-responsive electronic skin for quantitative vocal recognition
Lee, S., Kim, J., Yun, I., Bae, G. Y., Kim, D., Park, S., Yi, I.-M., Moon, W., Chung, Y., & Cho, K. (2019) · Nature Communications · doi:10.1038/s41467-019-10465-w · Cited by 195
Guidelines for Speech Recording and Acoustic Analyses in Dysarthrias of Movement Disorders
Rusz, J., Tykalova, T., Ramig, L. O., & Tripoliti, E. (2021) · Movement Disorders · doi:10.1002/mds.28465 · Cited by 170
“Ideally, a soundproof booth should be used to ensure the lowest ambient noise level, which needs to be at least 10 dB less than the quietest speech utterance of interest, which is lower than 48 dB C-weighted in ideal settings.(25) As many clinical rooms have an ambient noise level of 50- to 60-dB sound pressure level…”
BackgroundTutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech
Švec, J. G., & Granqvist, S. (2018) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2017_jslhr-s-17-0095 · Cited by 166
Self-citation
Metadata
- Authors
- Šrámková, H., Granqvist, S., Herbst, C. T., & Švec, J. G.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2015-01-01
- Volume
- 137
- Issue
- 1
- Pages
- 407-418
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1995624940
- Cited by
- 53
- References
- 1
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.