CoChat

Concurrent Validity of a Continuous Glucose-Monitoring System at Rest and During and Following a High-Intensity Interval Training Session

Clavel, Pauline, Tiollier, Eve, Leduc, Cédric, Fabre, Marina, Lacome, Mathieu, Buchheit, Martin · 2022 · International Journal of Sports Physiology and Performance
Cited by 21

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Purpose: To assess the concurrent validity of a continuous blood-glucose-monitoring system (CGM) postbreakfast, preexercise, exercise, and postexercise, while assessing the impact of 2 different breakfasts on the observed level of validity. Methods: Eight nondiabetic recreational athletes (age = 30.8 [9.5] y; height = 173.6 [6.6] cm; body mass = 70.3 [8.1] kg) took part in the study. Blood glucose concentration was monitored every 10 minutes using both a CGM (FreeStyle Libre, Abbott, France) and finger-prick blood glucose measurements (FreeStyle Optimum) over 4 different periods (postbreakfast, preexercise, exercise, and postexercise). Two different breakfasts (carbohydrates [CHO] and protein oriented) over 2 days (2 × 2 d in total) were used. Statistical analyses included the Bland–Altman method, standardized mean bias (expressed in standardized units), median absolute relative difference, and the Clarke error grid analysis. Results: Overall, mean bias was trivial to small at postbreakfast (effect size ± 90% confidence limits: −0.12 ± 0.08), preexercise (−0.08 ± 0.08), and postexercise (0.25 ± 0.14), while moderate during exercise (0.66 ± 0.09). A higher median absolute relative difference was observed during exercise (13.6% vs 7%–9.5% for the other conditions). While there was no effect of the breakfast type on the median absolute relative difference results, error grid analysis revealed a higher value in zone D (ie, clinically unsafe zone) during exercise for CHO (10.5%) compared with protein (1.6%). Conclusion: The CGM device examined in this study can only be validly used at rest, after both a CHO and protein-rich breakfast. Using CGM to monitor blood glucose concentration during exercise is not recommended. Moreover, the accuracy decreased when CHO were consumed before exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1123/ijspp.2021-0222

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 38

  1. Clarke, 1987, Evaluating clinical accuracy of systems for self-monitoring of blood glucose, Diabetes Care, 10, 622, 10.2337/diacare.10.5.622 · DOI · Paper page
  2. Gallwitz, 2009, Implications of postprandial glucose and weight control in people with type 2 diabetes: understanding and implementing the International Diabetes Federation guidelines, Diabetes Care, 32, S322, 10.2337/dc09-S331 · DOI · Paper page
  3. Gómez, 2016, Continuous glucose monitoring versus capillary point-of-care testing for inpatient glycemic control in type 2 diabetes patients hospitalized in the general ward and treated with a basal bolus insulin regimen, J Diabetes Sci Technol, 10, 325, 10.1177/1932296815602905 · DOI · Paper page
  4. Biagi, 2018, Accuracy of continuous glucose monitoring before, during, and after aerobic and anaerobic exercise in patients with type 1 diabetes mellitus, Biosensors, 8, 1, 10.3390/bios8010022 · DOI · Paper page
  5. Rodrigo, 2017, Accuracy and reliability between glucose meters: a study under normal clinical practice conditions, Semer - Med Fam, 43, 20
  6. Altman, 1994, Diagnostic tests. 1: sensitivity and specificity, BMJ, 308, 1552, 10.1136/bmj.308.6943.1552 · DOI · Paper page
  7. Richter, 2013, Exercise, GLUT4, and skeletal muscle glucose uptake, Physiol Rev, 93, 993, 10.1152/physrev.00038.2012 · DOI · Paper page
  8. Clarke, 1987, Evaluating clinical accuracy of systems for self-monitoring of blood glucose, Diabetes Care, 10, 622, 10.2337/diacare.10.5.622 · DOI · Paper page
  9. Rodrigo, 2017, Accuracy and reliability between glucose meters: a study under normal clinical practice conditions, Semer - Med Fam, 43, 20
  10. Greene, 2017, State-of-the-art methods for skeletal muscle glycogen analysis in athletes-the need for novel non-invasive techniques, Biosensors, 7, 1, 10.3390/bios7010011 · DOI · Paper page
  11. Buchheit, 2008, The 30-15 Intermittent fitness test: accuracy for individualizing interval training of young intermittent sport players, J Strength Cond Res, 22, 365, 10.1519/JSC.0b013e3181635b2e · DOI · Paper page
  12. Cavalot, 2011, Postprandial blood glucose predicts cardiovascular events and all-cause mortality in type 2 diabetes in a 14-year follow-up: lessons from the San Luigi Gonzaga diabetes study, Diabetes Care, 34, 2237, 10.2337/dc10-2414 · DOI · Paper page
  13. Bradley, 2016, Muscle glycogen utilisation during rugby match play: effects of pre-game carbohydrate, J Sci Med Sport, 19, 1033, 10.1016/j.jsams.2016.03.008 · DOI · Paper page
  14. Harper, 2016, Physiological and performance effects of carbohydrate gels consumed prior to the extra-time period of prolonged simulated soccer match-play, J Sci Med Sport, 19, 509, 10.1016/j.jsams.2015.06.009 · DOI
  15. Reiterer, 2017, Significance and reliability of MARD for the accuracy of CGM systems, J Diabetes Sci Technol, 11, 59, 10.1177/1932296816662047 · DOI · Paper page
  16. Kingsley, 2014, Effects of carbohydrate-hydration strategies on glucose metabolism, sprint performance and hydration during a soccer match simulation in recreational players, J Sci Med Sport, 17, 239, 10.1016/j.jsams.2013.04.010 · DOI · Paper page
  17. Freckmann, 2013, Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel, J Diabetes Sci Technol, 7, 842, 10.1177/193229681300700406 · DOI · Paper page
  18. Hopkins, 2000, Measures of reliability in sports medicine and science, Sports Med, 30, 1, 10.2165/00007256-200030010-00001 · DOI · Paper page
  19. Kumareswaran, 2013, Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy, Diabetes Technol Ther, 15, 223, 10.1089/dia.2012.0292 · DOI
  20. Freckmann, 2013, Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel, J Diabetes Sci Technol, 7, 842, 10.1177/193229681300700406 · DOI · Paper page
  21. Altman, 1994, Diagnostic tests. 1: sensitivity and specificity, BMJ, 308, 1552, 10.1136/bmj.308.6943.1552 · DOI · Paper page
  22. Kumareswaran, 2013, Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy, Diabetes Technol Ther, 15, 223, 10.1089/dia.2012.0292 · DOI
  23. Thomas, 2016, Blood glucose levels of subelite athletes during 6 days of free living, J Diabetes Sci Technol, 10, 1335, 10.1177/1932296816648344 · DOI · Paper page
  24. Greene, 2017, State-of-the-art methods for skeletal muscle glycogen analysis in athletes-the need for novel non-invasive techniques, Biosensors, 7, 1, 10.3390/bios7010011 · DOI · Paper page
  25. Hall, 2018, Glucotypes reveal new patterns of glucose dysregulation, PLoS Biol, 16, 1, 10.1371/journal.pbio.2005143 · DOI · Paper page
  26. Hopkins, 2000, Measures of reliability in sports medicine and science, Sports Med, 30, 1, 10.2165/00007256-200030010-00001 · DOI · Paper page
  27. Bradley, 2016, Muscle glycogen utilisation during rugby match play: effects of pre-game carbohydrate, J Sci Med Sport, 19, 1033, 10.1016/j.jsams.2016.03.008 · DOI · Paper page
  28. Thomas, 2016, Blood glucose levels of subelite athletes during 6 days of free living, J Diabetes Sci Technol, 10, 1335, 10.1177/1932296816648344 · DOI · Paper page
  29. Reiterer, 2017, Significance and reliability of MARD for the accuracy of CGM systems, J Diabetes Sci Technol, 11, 59, 10.1177/1932296816662047 · DOI · Paper page
  30. Kingsley, 2014, Effects of carbohydrate-hydration strategies on glucose metabolism, sprint performance and hydration during a soccer match simulation in recreational players, J Sci Med Sport, 17, 239, 10.1016/j.jsams.2013.04.010 · DOI · Paper page
  31. Biagi, 2018, Accuracy of continuous glucose monitoring before, during, and after aerobic and anaerobic exercise in patients with type 1 diabetes mellitus, Biosensors, 8, 1, 10.3390/bios8010022 · DOI · Paper page
  32. Buchheit, 2008, The 30-15 Intermittent fitness test: accuracy for individualizing interval training of young intermittent sport players, J Strength Cond Res, 22, 365, 10.1519/JSC.0b013e3181635b2e · DOI · Paper page
  33. Harper, 2016, Physiological and performance effects of carbohydrate gels consumed prior to the extra-time period of prolonged simulated soccer match-play, J Sci Med Sport, 19, 509, 10.1016/j.jsams.2015.06.009 · DOI
  34. Gallwitz, 2009, Implications of postprandial glucose and weight control in people with type 2 diabetes: understanding and implementing the International Diabetes Federation guidelines, Diabetes Care, 32, S322, 10.2337/dc09-S331 · DOI · Paper page
  35. Rothschild, 2020, What should I eat before exercise? Pre-exercise nutrition and the response to endurance exercise: current prospective and future directions, Nutrients, 12, 1, 10.3390/nu12113473 · DOI · Paper page
  36. Gómez, 2016, Continuous glucose monitoring versus capillary point-of-care testing for inpatient glycemic control in type 2 diabetes patients hospitalized in the general ward and treated with a basal bolus insulin regimen, J Diabetes Sci Technol, 10, 325, 10.1177/1932296815602905 · DOI · Paper page
  37. Rothschild, 2020, What should I eat before exercise? Pre-exercise nutrition and the response to endurance exercise: current prospective and future directions, Nutrients, 12, 1, 10.3390/nu12113473 · DOI · Paper page
  38. Jeukendrup, 2017, Periodized nutrition for athletes, Sports Med, 47, 51, 10.1007/s40279-017-0694-2 · DOI · Paper page

Cited by

See all 21

Metadata

Authors
Clavel, P., Tiollier, E., Leduc, C., Fabre, M., Lacome, M., & Buchheit, M.
Venue
International Journal of Sports Physiology and Performance
Published
2022-04-01
Volume
17
Issue
4
Pages
627-633
ISSN
  • 1555-0265
  • 1555-0273
Cited by
21
References
4

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Concurrent Validity of a Continuous Glucose-Monitoring System at Rest and During and Following a High-Intensity Interval Training Session. https://app.cochat.ai/papers/10.1123/ijspp.2021-0222
The paper
Clavel, P., Tiollier, E., Leduc, C., Fabre, M., Lacome, M., & Buchheit, M. (2022). Concurrent Validity of a Continuous Glucose-Monitoring System at Rest and During and Following a High-Intensity Interval Training Session. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2021-0222

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.