Soft and ion-conducting hydrogel artificial tongue for astringency perception
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Artificial tongue for astringency perception is demonstrated with a saliva-like chemiresistive ionic hydrogel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“Among these strategies, a majority of artificial tongues developed for sensing the five basic tastes adopt specific target-binding systems that include aptamers (8), enzymes (9), or taste receptor– functionalized electronics (6) to achieve high selectivity and a low limit of detection.”
BackgroundTannins and Human Health: A Review
Chung, K.-T., Wong, T. Y., Wei, C.-I., Huang, Y.-W., & Lin, Y. (1998) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408699891274273 · Cited by 1,996 · cited 1×
“Polyphenols are beneficial as strong antioxidant and anti-inflammatory substances (12), but they may also provoke negative nutritional impacts that can often be lethal when high doses are consumed (13).”
BackgroundDietary polyphenols, oxidative stress and antioxidant and anti-inflammatory effects
Zhang, H., & Tsao, R. (2016) · Current Opinion in Food Science · doi:10.1016/j.cofs.2016.02.002 · Cited by 1,519 · cited 1×
“Polyphenols are beneficial as strong antioxidant and anti-inflammatory substances (12), but they may also provoke negative nutritional impacts that can often be lethal when high doses are consumed (13).”
BackgroundSkin-inspired hydrogel–elastomer hybrids with robust interfaces and functional microstructures
Yuk, H., Zhang, T., Parada, G. A., Liu, X., & Zhao, X. (2016) · Nature Communications · doi:10.1038/ncomms12028 · Cited by 1,035 · cited 1×
“To overcome this issue, hydrogels were encapsulated with elastomers (36), which cannot be applied in the artificial tongue due to the limited transport of tastants through the elastomer and inside the active matrix.”
BackgroundInstant tough bonding of hydrogels for soft machines and electronics
Wirthl, D., Pichler, R., Drack, M., Kettlguber, G., Moser, R., Gerstmayr, R., Hartmann, F., Bradt, E., Kaltseis, R., Siket, C. M., et al. (2017) · Science Advances · doi:10.1126/sciadv.1700053 · Cited by 471 · cited 1×
“Furthermore, the interface between dissimilar hydrogel and electrode should be tight and conformal, which can be achieved through physical (24) or chemical bonding (25).”
BackgroundTransparent hydrogel with enhanced water retention capacity by introducing highly hydratable salt
Bai, Y., Chen, B., Xiang, F., Zhou, J., Wang, H., & Suo, Z. (2014) · Applied Physics Letters · doi:10.1063/1.4898189 · Cited by 383 · cited 2×
“5Bii, a higher degree of astringency is observed when the artificial tongue is attached to the skin and core, while flesh shows relatively low astringency (37).”
Background
Cited by
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Naturally sourced hydrogels: emerging fundamental materials for next-generation healthcare sensing
Wang, Z., Wei, H., Huang, Y., Wei, Y., & Chen, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00813k · Cited by 392
A fully hydrophobic ionogel enables highly efficient wearable underwater sensors and communicators
Wei, J., Zheng, Y., & Chen, T. (2021) · Materials Horizons · doi:10.1039/d1mh00998b · Cited by 307
Hydrogel-Based Sensor Networks: Compositions, Properties, and Applications—A Review
Sun, X., Agate, S., Salem, K. S., Lucia, L., & Pal, L. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01011 · Cited by 279
3D-printed PEDOT:PSS for soft robotics
Li, J., Cao, J., Lu, B., & Gu, G. (2023) · Nature Reviews Materials · doi:10.1038/s41578-023-00587-5 · Cited by 274
Metadata
- Authors
- Yeom, J., Choe, A., Lim, S., Lee, Y., Na, S., & Ko, H.
- Venue
- Science Advances
- Published
- 2020-06-05
- Volume
- 6
- Issue
- 23
- Pages
- eaba5785-eaba5785
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W3034050196
- Cited by
- 140
- References
- 6
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Soft and ion-conducting hydrogel artificial tongue for astringency perception. https://app.cochat.ai/papers/10.1126/sciadv.aba5785
- The paper
- Yeom, J., Choe, A., Lim, S., Lee, Y., Na, S., & Ko, H. (2020). Soft and ion-conducting hydrogel artificial tongue for astringency perception. Science Advances. https://doi.org/10.1126/sciadv.aba5785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.