Cited by 29Luminescence and Fluorescent MaterialsPhotodynamic Therapy Research StudiesNanoplatforms for cancer theranostics

Pyrrolopyrrole aza-BODIPY-based NIR-II fluorophores for in vivo dynamic vascular dysfunction visualization of vascular-targeted photodynamic therapy

Open access
Bian, Shuaishuai, Zheng, Xiuli, Liu, Weimin, Li, Jihao, Gao, Zekun, Ren, Haohui, Zhang, Wenjun, Lee, Chun-Sing +1 more·2023·Biomaterials

Abstract

Real-time monitoring vascular responses is crucial for evaluating the therapeutic effects of vascular-targeted photodynamic therapy (V-PDT). Herein, we developed a highly-stable and bright aggregation induced emission (AIE) fluorophore (PTPE3 NP) for dynamic fluorescence (FL) imaging of vascular dysfunction beyond 1300 nm window during V-PDT. The superior brightness (ϵ max Φ f>1000 nm ≈ 180.05 M-1 cm-1) and high resolution of PTPE3 NP affords not only high-clarity images of whole-body and local vasculature (hindlimbs, mesentery, and tumor) but also high-speed video imaging for tracking blood circulation process. By virtue of the NPs' prolonged blood circulation time (t 1/2 ≈ 86.5 min) and excellent photo/chemical (pH, RONS) stability, mesenteric and tumor vascular dysfunction (thrombosis formation, vessel occlusion, and hemorrhage) can be successfully visualized during V-PDT by FL imaging for the first time. Furthermore, the reduction of blood flow velocity (BFV) can be monitored in real time for precisely evaluating efficacy of V-PDT. These provide a powerful approach for assessing vascular responses during V-PDT and promote the development of advanced fluorophores for biological imaging.

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2023.122130

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bian, S., Zheng, X., Liu, W., Li, J., Gao, Z., Ren, H., Zhang, W., Lee, C.-S., & Wang, P.
Affiliations
  • Chinese Academy of Sciences (CN)
  • City University of Hong Kong (HK)
Corresponding author
  • Zheng, Xiuli
  • Lee, Chun-Sing
  • Wang, Pengfei
Venue
Biomaterials
Publisher
Elsevier BV
Published
2023-07
Volume
298
Pages
122130
ISSN
0142-9612 (ISSN-L)
OpenAlex
W4367056759
Cited by
29
References
52
Citations by year
2026: 7 · 2025: 12 · 2024: 9 · 2023: 1
FWCI
2.13
Type
journal article
Language
en
Open access
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
  • CityU Scholars (submittedVersion, cc-by-nc-nd)
Funders
National Natural Science Foundation of China (21873110, 61720106014, 62005294)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Photodynamic Therapy Research Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
Keywords
NIR-II fluorescence imaging, aggregation-induced emission, vascular-targeted photodynamic therapy, vascular dysfunction, thrombosis, blood flow velocity, tumor vasculature, mesenteric vasculature, blood circulation time
MeSH terms
Animals, Boron Compounds, Humans, Neoplasms, Photochemotherapy, Optical Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review