First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I
Open accessAbstract
With preparations underway for extended-duration crewed deep space missions, the health risks of solar particle events (SPEs) to astronauts are becoming increasingly pertinent. To address this hazard, the AstroRad vest, a personal radiation shielding garment providing targeted organ protection, was tested during Artemis I. Two anthropomorphic female phantoms, equipped with internal and external passive and active dosimeters, were flown aboard the Orion spacecraft: one unshielded and the other wearing AstroRad. Inner Van Allen belt transit active dosimeter measurements were extrapolated to simulate SPE scenarios, predicting effective dose reductions of ∼60% for an August 1972-like SPE and nearly 40% for an October 1989-like SPE, varying slightly with anatomical model. Such reductions could spare astronauts the equivalent of up to 193 and 131 days of deep space radiation exposure, respectively. These findings demonstrate that wearable shielding such as AstroRad could serve as a vital element for safe and sustainable human deep space exploration.
Overview
CoChat Summary
## TL;DR
This paper uses Artemis I dosimeter data plus Monte Carlo simulations to estimate how much the AstroRad wearable radiation vest would reduce astronaut dose during major solar particle events (SPEs). It finds large modeled benefits: about 60% dose reduction for an August 1972–like SPE and about 39% for an October 1989–like SPE, with targeted shielding outperforming a uniform full-body suit.
## Key findings
- In the Artemis I inner Van Allen belt transit, the vest was associated with a total effective dose reduction of 25.8 ± 0.4% for the phantom wearing AstroRad, from 1.61 ± 0.005 to 1.19 ± 0.006 mSv.
- For an August 1972–like SPE, the vest was predicted to reduce total effective dose from 222.3 to 87.5 mSv (60.7%) for the torso phantom; with a whole-body female phantom, from 204.2 to 85.3 mSv (58.2%).
- For an October 1989–like SPE, the vest was predicted to reduce total effective dose from 233.5 to 143.6 mSv (38.5%) for the torso phantom; with a whole-body female phantom, from 219.0 to 138.2 mSv (36.9%).
- The targeted AstroRad design improved effective-dose reduction by ~30% compared with a uniform full-body HDPE suit of the same mass.
- The paper estimates the vest could extend permissible spaceflight time by 59 to 193 days for an August 1972–like SPE and 40 to 131 days for an October 1989–like SPE, depending on solar-cycle phase.
## Methods
- The study used the MARE experiment on Artemis I, with two anthropomorphic female phantoms in Orion: Zohar wearing AstroRad and Helga unshielded as baseline.
- Dose was measured with active dosimeters (DLR M-42s and NASA CADs) placed internally and externally on the phantoms, then analyzed with GEANT4 Monte Carlo radiation transport simulations.
- The Artemis I inner Van Allen belt data were first used to validate the simulation, then the model was extrapolated to historical SPE spectra using the August 1972 and October 1989 event parameterizations.
## Limitations
- The paper states that the first validation phase relied on a shielding model that simplified the Orion hull to aluminum and polyethylene and did not account for many nonstructural interior objects, which may affect secondary radiation production.
- It also notes that the AE9/AP9 trapped-radiation models are climatological and do not capture the exact Artemis I spectrum or radiation directionality; this is stated in the paper as a source of uncertainty.
- Evident from the text: the SPE results are model-based extrapolations from Artemis I inner Van Allen belt data, so the core efficacy estimates are not direct measurements of an SPE.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
10 Valid · 2 Not valid · 14 Not checked · 54 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Although SPEs propagate outward from the Sun, the event-integrated flux becomes nearly isotropic beyond ∼1 astronomical unit (6), indicating that any radiation shielding should maximize solid angle of coverage.”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Partly supportedcites [6] sourceExperimental — accuracy not yet measured
Section 2.3 (page not specified) says scattered particles may arrive at 1 au later, nearly isotropized, following an anisotropic onset; the Summary likewise describes a transition to an isotropic phase. The paper does not establish that the event-integrated flux is nearly isotropic beyond approximately 1 au. Its model also ignores cross-field transport, so the cited result does not address coverage over all directions. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“During an SPE, the flux of protons with energies of more than 10 MeV may increase by four to five orders of magnitude over periods of time ranging from several hours to a few days (3).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Partly supportedcites [3] sourceExperimental — accuracy not yet measured
Section 2.4 describes proton-flux profiles over the first three days of two SPEs, and Section 2.6 shows fluxes for proton energies above 10 MeV. Neither passage establishes a four-to-five-order-of-magnitude increase over pre-event flux, and the cited passage on a four-order increase in Section 5 concerns electronic upset rates from heavy ions, not proton flux. (LLM, conf=0.78)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Female phantoms were chosen for this experiment due to females having larger risk of radiation-induced carcinogenesis (based on currently accepted risk models) (32–34).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Not checked — no full text of the sourcecites [32] source
- Not matchedcites [33]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Supportedcites [34] source
The paper’s model projections support the cited rationale: Table 5 gives a 1.88% cancer-death risk for 45-year-old never-smoker females on a one-year deep-space mission under DDREF Model A, while Table 6 gives a 1.3% estimate for comparable males using all solid-cancer experiments. The paper does not discuss the citing authors’ choice of phantoms; that choice is their own application of the modeled risk difference. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“The phantom at seat 4, provided by DLR, was named Helga and was not equipped with a vest, serving as the radiation exposure baseline (Helga was not an exact experimental control as the median aluminum shielding was 24.84 g/cm2 at seat 4 versus 24.40 g/cm2 at seat 3) (35, 36).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Not matchedcites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Could not verifycites [36] sourceExperimental — accuracy not yet measured
The Main section identifies Helga as a radiation phantom, but does not compare shielding at seats 3 and 4 or describe Helga as an inexact control. The Methods section says its shielding-distribution analysis was limited to HERA instruments; searches for 24.84, 24.40, and the seat comparison found no supporting passage in our copy. (LLM, conf=0.76)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Due to the regenerative nature of bone marrow, as little as 2.5% of the entire body’s bone marrow must be spared in order for an individual to experience a significantly reduced likelihood of developing hematopoietic ARS (61, 62).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > DISCUSSION
What the sources say
- Partly supportedcites [61] sourceExperimental — accuracy not yet measured
The Results (H-ARS; page not provided) report that nonhuman primates with approximately 2.5% marrow sparing had 58.3% mortality after 10 Gy, whereas total-body irradiation at that dose was uniformly lethal. The paper studies survival and hematopoietic recovery, not a significantly reduced likelihood of developing H-ARS; it describes the spared animals as experiencing H-ARS and does not establish the claim for humans. (LLM, conf=0.88)
- Partly supportedcites [62] sourceExperimental — accuracy not yet measured
The Results section ('The threshold fraction of BM spared for H-ARS survival'; page unavailable) suggests that sparing about 2.5% of marrow can enhance hematopoietic recovery and survival from H-ARS in nonhuman primates. It does not show a significantly reduced likelihood of developing H-ARS: the 2.5%-sparing protocol remained a model of H-ARS and had greater myelosuppression and mortality than the 5%-sparing protocol. The claim also generalizes the primate finding to any individual. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
51 more claims · 3 with their cited sources checked
Create a free account to see all 80 claims and every source verdict.
- Probably not a substantial claim. 7
- It may state two separate claims as one. 20
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194 · cited 4×
“The chemical compositions for the CIRS proprietary tissue-equivalent resins corresponding to average soft tissue, average bone, cartilage, spinal cord, spinal disks, lung, brain, sinus, and breast were drawn from table A1 in International Commission on Radiation Units and Measurements (ICRU) Report 46 ( 75 ), while th…”
InfluentialZur Theorie des Durchgangs schneller Korpuskularstrahlen durch Materie
Bethe, H. (1930) · Annalen der Physik · doi:10.1002/andp.19303970303 · Cited by 4,076 · cited 1×
“…core of the MARE AstroRad vest is composed of HDPE, which has the largest percent composition by mass of hydrogen atoms of any nonvolatile and nontoxic material, maximizing the shielding efficacy against space radiation per unit mass as determined by the Bethe radiation stopping formula ( 39 ).”
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604 · cited 1×
“…studies of clinical exposures and radiation incidents/accidents that bone marrow failure is the primary cause of death for acute radiation exposures up to as high as 6 Gy, beyond which damage to gastrointestinal tissue begins to manifest as an additional contributing factor to mortality ( 60 ).”
4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287 · cited 2×
“3C) ( 40 , 41 ).”
Self-citationA signature of cosmic-ray increase in AD 774–775 from tree rings in Japan
Miyake, F., Nagaya, K., Masuda, K., & Nakamura, T. (2012) · Nature · doi:10.1038/nature11123 · Cited by 539 · cited 1×
“Concentrations of cosmogenic nuclides found in tree rings and ice cores give evidence of years with integrated fluence exceeding measurements from the space era by one to two orders of magnitude ( 55 – 59 ).”
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528
Space Radiation: The number one risk to astronaut health beyond low earth orbit
Chancellor, J., Scott, G., & Sutton, J. (2014) · Life · doi:10.3390/life4030491 · Cited by 455 · cited 1×
“…and magnetic field is not available beyond low Earth orbit (LEO) and astronauts will have to contend with exposure to the compositionally complex, spatially and temporally variable space radiation environment, introducing critical risks to crew health and the completion of mission objectives ( 2 ).”
Earth's Van Allen Radiation Belts: From Discovery to the Van Allen Probes Era
Li, W., & Hudson, M. K. (2019) · Journal of Geophysical Research: Space Physics · doi:10.1029/2018ja025940 · Cited by 310 · cited 1×
“S1) ( 37 ).”
Cited by
Metadata
- Authors
- Houri, J. M., Berger, T., Gaza, R., Hussein, H., Schwarz, S., Waterman, G., Matthiä, D., Marsalek, K., Przybyla, B., Aeckerlein, J., Radenhaeuser, M., Kasemann, M., Coderre, K., Segars, W. P., Samei, E., Kapadia, A. J., Lee, K., Laramore, D., George, S. P., Semones, E., & Milstein, O.
- Affiliations
- StemRad Inc., Tampa, FL, USA.
- Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
- Leidos (United States) (US)
- Lockheed Martin (United States) (US)
- Israel Space Agency (IL)
- German Aerospace Center (DLR), Institute of Aerospace Medicine, Radiation Biology Department, Cologne, Germany.
- Duke University (US)
- Oak Ridge National Laboratory (US)
- The Aerospace Corporation (US)
- National Aeronautics and Space Administration (US)
- Corresponding author
- Houri, Jordan M.
- Milstein, Oren
- ORCID
- Venue
- Science Advances
- Published
- 2026-08-14
- Volume
- 12
- Issue
- 33
- Pages
- eadz1892-eadz1892
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC13464478
- OpenAlex
- W7202264997
- Cited by
- 2
- References
- 60
- Citations by year
- 2026: 2
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Science Advances (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- elib (German Aerospace Center) (submittedVersion)
- Funders
- National Institutes of Health (R01EB001838, P41EB028744)
- National Aeronautics and Space Administration (NNJ15HK11B)
- Deutsches Zentrum für Luft- und Raumfahrt (2475019, 2475075)
- Israel Space Agency (4501432315)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- solar energetic particle events, astronaut radiation exposure, deep space exploration, Artemis I, Orion spacecraft, anthropomorphic phantom, passive dosimeters, radiation belts, effective dose reduction, crewed lunar missions
- MeSH terms
- Wearable Electronic Devices, Cosmic Radiation, Female, Humans, Radiation Protection, Space Flight, Astronauts, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I. https://app.cochat.ai/papers/10.1126/sciadv.adz1892
- The paper
- Houri, J. M., Berger, T., Gaza, R., Hussein, H., Schwarz, S., Waterman, G., Matthiä, D., Marsalek, K., Przybyla, B., Aeckerlein, J., Radenhaeuser, M., Kasemann, M., Coderre, K., Segars, W. P., Samei, E., Kapadia, A. J., Lee, K., Laramore, D., George, S. P., . . . Milstein, O. (2026). First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I. Science Advances. https://doi.org/10.1126/sciadv.adz1892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.