First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index; 14 of the 57 sources its claims cite were checked for support.
Abstract
With preparations underway for extended-duration crewed deep space missions, the health risks of solar particle events (SPEs) to astronauts are becoming increasingly pertinent. To address this hazard, the AstroRad vest, a personal radiation shielding garment providing targeted organ protection, was tested during Artemis I. Two anthropomorphic female phantoms, equipped with internal and external passive and active dosimeters, were flown aboard the Orion spacecraft: one unshielded and the other wearing AstroRad. Inner Van Allen belt transit active dosimeter measurements were extrapolated to simulate SPE scenarios, predicting effective dose reductions of ∼60% for an August 1972-like SPE and nearly 40% for an October 1989-like SPE, varying slightly with anatomical model. Such reductions could spare astronauts the equivalent of up to 193 and 131 days of deep space radiation exposure, respectively. These findings demonstrate that wearable shielding such as AstroRad could serve as a vital element for safe and sustainable human deep space exploration.
Overview
CoChat Summary
## TL;DR
This paper uses Artemis I dosimeter data plus Monte Carlo simulations to estimate how much the AstroRad wearable radiation vest would reduce astronaut dose during major solar particle events (SPEs). It finds large modeled benefits: about 60% dose reduction for an August 1972–like SPE and about 39% for an October 1989–like SPE, with targeted shielding outperforming a uniform full-body suit.
## Key findings
- In the Artemis I inner Van Allen belt transit, the vest was associated with a total effective dose reduction of 25.8 ± 0.4% for the phantom wearing AstroRad, from 1.61 ± 0.005 to 1.19 ± 0.006 mSv.
- For an August 1972–like SPE, the vest was predicted to reduce total effective dose from 222.3 to 87.5 mSv (60.7%) for the torso phantom; with a whole-body female phantom, from 204.2 to 85.3 mSv (58.2%).
- For an October 1989–like SPE, the vest was predicted to reduce total effective dose from 233.5 to 143.6 mSv (38.5%) for the torso phantom; with a whole-body female phantom, from 219.0 to 138.2 mSv (36.9%).
- The targeted AstroRad design improved effective-dose reduction by ~30% compared with a uniform full-body HDPE suit of the same mass.
- The paper estimates the vest could extend permissible spaceflight time by 59 to 193 days for an August 1972–like SPE and 40 to 131 days for an October 1989–like SPE, depending on solar-cycle phase.
## Methods
- The study used the MARE experiment on Artemis I, with two anthropomorphic female phantoms in Orion: Zohar wearing AstroRad and Helga unshielded as baseline.
- Dose was measured with active dosimeters (DLR M-42s and NASA CADs) placed internally and externally on the phantoms, then analyzed with GEANT4 Monte Carlo radiation transport simulations.
- The Artemis I inner Van Allen belt data were first used to validate the simulation, then the model was extrapolated to historical SPE spectra using the August 1972 and October 1989 event parameterizations.
## Limitations
- The paper states that the first validation phase relied on a shielding model that simplified the Orion hull to aluminum and polyethylene and did not account for many nonstructural interior objects, which may affect secondary radiation production.
- It also notes that the AE9/AP9 trapped-radiation models are climatological and do not capture the exact Artemis I spectrum or radiation directionality; this is stated in the paper as a source of uncertainty.
- Evident from the text: the SPE results are model-based extrapolations from Artemis I inner Van Allen belt data, so the core efficacy estimates are not direct measurements of an SPE.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
10 Valid · 2 Not valid · 14 Not checked · 54 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Although SPEs propagate outward from the Sun, the event-integrated flux becomes nearly isotropic beyond ∼1 astronomical unit (6), indicating that any radiation shielding should maximize solid angle of coverage.”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Partly supportedcites [6] sourceExperimental — accuracy not yet measured
Section 2.3 (page not specified) says scattered particles may arrive at 1 au later, nearly isotropized, following an anisotropic onset; the Summary likewise describes a transition to an isotropic phase. The paper does not establish that the event-integrated flux is nearly isotropic beyond approximately 1 au. Its model also ignores cross-field transport, so the cited result does not address coverage over all directions. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“During an SPE, the flux of protons with energies of more than 10 MeV may increase by four to five orders of magnitude over periods of time ranging from several hours to a few days (3).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Partly supportedcites [3] sourceExperimental — accuracy not yet measured
Section 2.4 describes proton-flux profiles over the first three days of two SPEs, and Section 2.6 shows fluxes for proton energies above 10 MeV. Neither passage establishes a four-to-five-order-of-magnitude increase over pre-event flux, and the cited passage on a four-order increase in Section 5 concerns electronic upset rates from heavy ions, not proton flux. (LLM, conf=0.78)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Female phantoms were chosen for this experiment due to females having larger risk of radiation-induced carcinogenesis (based on currently accepted risk models) (32–34).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Not checked — no full text of the sourcecites [32] source
- Not matchedcites [33]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Supportedcites [34] source
The paper’s model projections support the cited rationale: Table 5 gives a 1.88% cancer-death risk for 45-year-old never-smoker females on a one-year deep-space mission under DDREF Model A, while Table 6 gives a 1.3% estimate for comparable males using all solid-cancer experiments. The paper does not discuss the citing authors’ choice of phantoms; that choice is their own application of the modeled risk difference. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“The phantom at seat 4, provided by DLR, was named Helga and was not equipped with a vest, serving as the radiation exposure baseline (Helga was not an exact experimental control as the median aluminum shielding was 24.84 g/cm2 at seat 4 versus 24.40 g/cm2 at seat 3) (35, 36).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > INTRODUCTION
What the sources say
- Not matchedcites [35]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Could not verifycites [36] sourceExperimental — accuracy not yet measured
The Main section identifies Helga as a radiation phantom, but does not compare shielding at seats 3 and 4 or describe Helga as an inexact control. The Methods section says its shielding-distribution analysis was limited to HERA instruments; searches for 24.84, 24.40, and the seat comparison found no supporting passage in our copy. (LLM, conf=0.76)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Due to the regenerative nature of bone marrow, as little as 2.5% of the entire body’s bone marrow must be spared in order for an individual to experience a significantly reduced likelihood of developing hematopoietic ARS (61, 62).”
§ First evaluation of wearable radiation protection for human deep space exploration, as flown on Artemis I > DISCUSSION
What the sources say
- Partly supportedcites [61] sourceExperimental — accuracy not yet measured
The Results (H-ARS; page not provided) report that nonhuman primates with approximately 2.5% marrow sparing had 58.3% mortality after 10 Gy, whereas total-body irradiation at that dose was uniformly lethal. The paper studies survival and hematopoietic recovery, not a significantly reduced likelihood of developing H-ARS; it describes the spared animals as experiencing H-ARS and does not establish the claim for humans. (LLM, conf=0.88)
- Partly supportedcites [62] sourceExperimental — accuracy not yet measured
The Results section ('The threshold fraction of BM spared for H-ARS survival'; page unavailable) suggests that sparing about 2.5% of marrow can enhance hematopoietic recovery and survival from H-ARS in nonhuman primates. It does not show a significantly reduced likelihood of developing H-ARS: the 2.5%-sparing protocol remained a model of H-ARS and had greater myelosuppression and mortality than the 5%-sparing protocol. The claim also generalizes the primate finding to any individual. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
51 more claims · 3 with their cited sources checked
Create a free account to see all 80 claims and every source verdict.
- Probably not a substantial claim. 7
- It may state two separate claims as one. 20
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194 · cited 4×
“The chemical compositions for the CIRS proprietary tissue-equivalent resins corresponding to average soft tissue, average bone, cartilage, spinal cord, spinal disks, lung, brain, sinus, and breast were drawn from table A1 in International Commission on Radiation Units and Measurements (ICRU) Report 46 ( 75 ), while th…”
InfluentialZur Theorie des Durchgangs schneller Korpuskularstrahlen durch Materie
Bethe, H. (1930) · Annalen der Physik · doi:10.1002/andp.19303970303 · Cited by 4,076 · cited 1×
“…core of the MARE AstroRad vest is composed of HDPE, which has the largest percent composition by mass of hydrogen atoms of any nonvolatile and nontoxic material, maximizing the shielding efficacy against space radiation per unit mass as determined by the Bethe radiation stopping formula ( 39 ).”
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604 · cited 1×
“…studies of clinical exposures and radiation incidents/accidents that bone marrow failure is the primary cause of death for acute radiation exposures up to as high as 6 Gy, beyond which damage to gastrointestinal tissue begins to manifest as an additional contributing factor to mortality ( 60 ).”
4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287 · cited 2×
“3C) ( 40 , 41 ).”
Self-citationA signature of cosmic-ray increase in AD 774–775 from tree rings in Japan
Miyake, F., Nagaya, K., Masuda, K., & Nakamura, T. (2012) · Nature · doi:10.1038/nature11123 · Cited by 539 · cited 1×
“Concentrations of cosmogenic nuclides found in tree rings and ice cores give evidence of years with integrated fluence exceeding measurements from the space era by one to two orders of magnitude ( 55 – 59 ).”
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528
Space Radiation: The number one risk to astronaut health beyond low earth orbit
Chancellor, J., Scott, G., & Sutton, J. (2014) · Life · doi:10.3390/life4030491 · Cited by 455 · cited 1×
“…and magnetic field is not available beyond low Earth orbit (LEO) and astronauts will have to contend with exposure to the compositionally complex, spatially and temporally variable space radiation environment, introducing critical risks to crew health and the completion of mission objectives ( 2 ).”
Earth's Van Allen Radiation Belts: From Discovery to the Van Allen Probes Era
Li, W., & Hudson, M. K. (2019) · Journal of Geophysical Research: Space Physics · doi:10.1029/2018ja025940 · Cited by 310 · cited 1×
“S1) ( 37 ).”
Multiradionuclide evidence for the solar origin of the cosmic-ray events of ad 774/5 and 993/4
Mekhaldi, F., Muscheler, R., Adolphi, F., Aldahan, A., Beer, J., McConnell, J. R., Possnert, G., Sigl, M., Svensson, A., Synal, H.-A., et al. (2015) · Nature Communications · doi:10.1038/ncomms9611 · Cited by 265
Solar Proton Fluences for 1977-1983 Space Missions
KING, J. H. (1974) · Journal of Spacecraft and Rockets · doi:10.2514/3.62088 · Cited by 241 · cited 1×
“The 1972 SPE was modeled using the King parameterization ( 77 ), while the 1989 SPE was modeled using the Tylka parameterization (also known as the NASA design reference SPE) ( 78 , 79 ).”
Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
Segars, W. P., Bond, J., Frush, J., Hon, S., Eckersley, C., Williams, C. H., Feng, J., Tward, D. J., Ratnanather, J. T., Miller, M. I., et al. (2013) · Medical Physics · doi:10.1118/1.4794178 · Cited by 228
Self-citationPhysical and biological organ dosimetry analysis for international space station astronauts
Cucinotta, F. A., Kim, M.-H. Y., Willingham, V., & George, K. A. (2008) · Radiation Research · doi:10.1667/rr1330.1 · Cited by 196
Artemis: An Overview of NASA's Activities to Return Humans to the Moon
Creech, S., Guidi, J., & Elburn, D. (2022) · 2022 IEEE Aerospace Conference (AERO) · doi:10.1109/aero53065.2022.9843277 · Cited by 170 · cited 1×
“More than 50 years after the final Apollo mission, NASA’s Artemis program has set the goal of returning humans to deep space, beginning with a human presence in lunar orbit with regular landings on the lunar surface and leading to the first human missions to Mars ( 1 ).”
An improved model of galactic cosmic radiation for space exploration missions
Badhwar, G. D., & O'Neill, P. M. (1992) · International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements · doi:10.1016/1359-0189(92)90024-p · Cited by 149 · cited 1×
“…detector in the Orion crew cabin during the same time period), the dose rate is found to be 1.18 ± 0.03 mSv/day, which can be scaled to effective dose rates of ∼ 2.01 mSv/day during solar minimum and ∼ 0.615 mSv/day during solar maximum using the Badhwar-O’Neill 2020 GCR flux model ( 52 , 53 ).”
InfluentialBergonié, J., Tribondeau, L., & Bergonie, J. (1959) · Radiation Research · doi:10.2307/3570812 · Cited by 134 · cited 1×
“Female phantoms were chosen for this experiment due to females having larger risk of radiation-induced carcinogenesis (based on currently accepted risk models) ( 32 – 34 ).”
Reitz, G., Berger, T., Bilski, P., Facius, R., Hajek, M., Petrov, V., Puchalska, M., Zhou, D., Bossler, J., Akatov, Y., et al. (2009) · Radiation Research · doi:10.1667/rr1559.1 · Cited by 128
Self-citationPoole, C. M., Cornelius, I. M., Trapp, J., & Langton, C. M. (2012) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-012-0159-8 · Cited by 119 · cited 2×
“This analysis was performed by developing and running mission-calibrated Monte Carlo radiation transport simulations using the GEANT4 platform for the Van Allen transit phase of the mission ( 44 – 48 ).”
Shavers, M. R., Zapp, N., Barber, R. E., Wilson, J. W., Qualls, G., Toupes, L., Ramsey, S., Vinci, V., Smith, G., & Cucinotta, F. A. (2004) · Advances in Space Research · doi:10.1016/j.asr.2003.10.051 · Cited by 116
Predictions of space radiation fatality risk for exploration missions
Cucinotta, F. A., To, K., & Cacao, E. (2017) · Life Sciences in Space Research · doi:10.1016/j.lssr.2017.01.005 · Cited by 107
Geant4 hadronic physics for space radiation environment
Ivantchenko, A. V., Ivanchenko, V. N., Molina, J.-M. Q., & Incerti, S. L. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2011.610865 · Cited by 89 · cited 1×
“Monte Carlo radiation transport simulations were developed using GEANT4 version 10.7.3 with the “QBBC” physics list and run on an Oracle Cloud Infrastructure supercomputer using an AMD EPYC 7J13 processor with 128 CPU cores ( 44 – 47 ).”
InfluentialSpace Radiation Absorbed Dose Distribution in a Human Phantom
Badhwar, G. D., Atwell, W., Badavi, F. F., Yang, T. C., & Cleghorn, T. F. (2002) · Radiation Research · doi:10.1667/0033-7587(2002)157[0076:sraddi]2.0.co;2 · Cited by 86
Radiation Sensitivity of Human Bone Marrow Cells Measured by a Cell Culture Method
SENN, J. S., & McCULLOCH, E. A. (1970) · Blood · doi:10.1182/blood.v35.1.56.56 · Cited by 86 · cited 1×
“Based on the analysis in this study, together with the established human bone marrow lethality curve ( 64 ), a hypothetical SPE with the same spectral shape as the October 1989 SPE, but scaled up in intensity to deliver an average equivalent dose of 6 Gy-Eq to the RBM of an unshielded astronaut…”
The Badhwar‐O'Neill 2020 GCR Model
Slaba, T. C., & Whitman, K. (2020) · Space Weather · doi:10.1029/2020sw002456 · Cited by 78
Solar particle event storm shelter requirements for missions beyond low Earth orbit
Townsend, L. W., Adams, J. H., Blattnig, S. R., Clowdsley, M. S., Fry, D. J., Jun, I., McLeod, C. D., Minow, J. I., Moore, D. F., Norbury, J. W., et al. (2018) · Life Sciences in Space Research · doi:10.1016/j.lssr.2018.02.002 · Cited by 70 · cited 1×
“The 1972 SPE was modeled using the King parameterization ( 77 ), while the 1989 SPE was modeled using the Tylka parameterization (also known as the NASA design reference SPE) ( 78 , 79 ).”
Self-citationTree-rings reveal two strong solar proton events in 7176 and 5259 BCE
Brehm, N., Christl, M., Knowles, T. D. J., Casanova, E., Evershed, R. P., Adolphi, F., Muscheler, R., Synal, H.-A., Mekhaldi, F., Paleari, C. I., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28804-9 · Cited by 70
The MATROSHKA facility—dose determination during an EVA
Reitz, G., & Berger, T. (2006) · Radiation Protection Dosimetry · doi:10.1093/rpd/nci558 · Cited by 60 · cited 1×
“…collaboration co-led by the German Aerospace Center (DLR), the Israel Space Agency (ISA), and NASA and supported by StemRad and Lockheed Martin, building upon prior phantom studies in LEO ( 14 – 24 ) and heritage from European Space Agency (ESA) MATROSHKA (MTR) experiments on the ISS ( 25 – 31 ).”
Self-citationBerger, T., Bilski, P., Hajek, M., Puchalska, M., & Reitz, G. (2013) · Radiation Research · doi:10.1667/rr13148.1 · Cited by 58
Self-citationEffective Dose Equivalent on the Ninth Shuttle–Mir Mission (STS-91)
Yasuda, H., Badhwar, G. D., Komiyama, T., & Fujitaka, K. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0705:edeotn]2.0.co;2 · Cited by 56
Ginet, G. P., O’Brien, T. P., Huston, S. L., Johnston, W. R., Guild, T. B., Friedel, R., Lindstrom, C. D., Roth, C. J., Whelan, P., Quinn, R. A., et al. (2013) · The Van Allen Probes Mission · doi:10.1007/978-1-4899-7433-4_18 · Cited by 56
Badhwar, G. D., & Cucinotta, F. A. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)153[0001:acoddo]2.0.co;2 · Cited by 54
Singleterry, R. C. (2013) · Acta Astronautica · doi:10.1016/j.actaastro.2013.04.013 · Cited by 52 · cited 1×
“Despite this, because of the predominance of lower energy protons in typical SPE spectra, this radiation can be attenuated by realistic levels of material shielding, unlike the low-flux but more penetrating chronic background galactic cosmic radiation (GCR) ( 5 ).”
The magnitude and effects of extreme solar particle events
Jiggens, P., Chavy-Macdonald, M.-A., Santin, G., Menicucci, A., Evans, H., & Hilgers, A. (2014) · Journal of Space Weather and Space Climate · doi:10.1051/swsc/2014017 · Cited by 52 · cited 1×
“During an SPE, the flux of protons with energies of more than 10 MeV may increase by four to five orders of magnitude over periods of time ranging from several hours to a few days ( 3 ).”
Farese, A. M., Bennett, A. W., Gibbs, A. M., Hankey, K. G., Prado, K., Jackson, W., & MacVittie, T. J. (2019) · Health Physics · doi:10.1097/hp.0000000000000878 · Cited by 49 · cited 1×
“Due to the regenerative nature of bone marrow, as little as 2.5 % of the entire body’s bone marrow must be spared in order for an individual to experience a significantly reduced likelihood of developing hematopoietic ARS ( 61 , 62 ).”
InfluentialSpace radiation measurements during the Artemis I lunar mission
George, S. P., Gaza, R., Matthiä, D., Laramore, D., Lehti, J., Campbell-Ricketts, T., Kroupa, M., Stoffle, N., Marsalek, K., Przybyla, B., et al. (2024) · Nature · doi:10.1038/s41586-024-07927-7 · Cited by 47 · cited 4×
“In addition, the AE9/AP9 models do not account for the directionality of the trapped radiation, which has been shown by a companion study using MARE data to have a nonnegligible impact on dose ( 36 ).”
InfluentialSelf-citationVuolo, M., Baiocco, G., Barbieri, S., Bocchini, L., Giraudo, M., Gheysens, T., Lobascio, C., & Ottolenghi, A. (2017) · Life Sciences in Space Research · doi:10.1016/j.lssr.2017.08.003 · Cited by 47
Badhwar, G. D., & Cucinotta, F. A. (1998) · Radiation Research · doi:10.2307/3579953 · Cited by 34 · cited 1×
“…use of shielding materials such as high-density poly-ethylene (HDPE) has been extensively explored as environmental radiation protection in space ( 8 – 11 ), StemRad and Lockheed Martin worked to create a low-mass emergency countermeasure solution in the form of a personal radiation shielding…”
A water-filled garment to protect astronauts during interplanetary missions tested on board the ISS
Baiocco, G., Giraudo, M., Bocchini, L., Barbieri, S., Locantore, I., Brussolo, E., Giacosa, D., Meucci, L., Steffenino, S., Ballario, A., et al. (2018) · Life Sciences in Space Research · doi:10.1016/j.lssr.2018.04.002 · Cited by 32
Updated deterministic radiation transport for future deep space missions
Slaba, T. C., Wilson, J. W., Werneth, C. M., & Whitman, K. (2020) · Life Sciences in Space Research · doi:10.1016/j.lssr.2020.06.004 · Cited by 30
Simulations of the MATROSHKA experiment at the international space station using PHITS
Sihver, L., Sato, T., Puchalska, M., & Reitz, G. (2010) · Radiation and Environmental Biophysics · doi:10.1007/s00411-010-0288-y · Cited by 29
Radiation measured for MATROSHKA-1 experiment with passive dosimeters
Zhou, D., Semones, E., O'Sullivan, D., Zapp, N., Weyland, M. D., Reitz, G., Berger, T., & Benton, E. R. (2009) · Acta Astronautica · doi:10.1016/j.actaastro.2009.06.014 · Cited by 27
Self-citationParallel geometries in Geant4: Foundation and recent enhancements
Apostolakis, J., Asai, M., Cosmo, G., Howard, A. S., Ivanchenko, V., & Verderi, M. (2008) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2008.4774535 · Cited by 26 · cited 1×
“To incorporate the internal M-42 detector systems, dosimeter holder frames, and the polyether ether ketone (PEEK) support rod, parallel GEANT4 geometries were used ( 48 , 76 ).”
Puchalska, M., Bilski, P., Berger, T., Hajek, M., Horwacik, T., Körner, C., Olko, P., Shurshakov, V., & Reitz, G. (2014) · Radiation and Environmental Biophysics · doi:10.1007/s00411-014-0560-7 · Cited by 26
Self-citationEffective Dose Measured with a Life Size Human Phantom in a Low Earth Orbit Mission
YASUDA, H. (2009) · Journal of Radiation Research · doi:10.1269/jrr.08105 · Cited by 26
Low earth orbit radiation dose distribution in a phantom head
Konradi, A., Atwell, W., Badhwar, G. D., Cash, B. L., & Hardy, K. A. (1992) · International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements · doi:10.1016/1359-0189(92)90084-9 · Cited by 26 · cited 1×
“…collaboration co-led by the German Aerospace Center (DLR), the Israel Space Agency (ISA), and NASA and supported by StemRad and Lockheed Martin, building upon prior phantom studies in LEO ( 14 – 24 ) and heritage from European Space Agency (ESA) MATROSHKA (MTR) experiments on the ISS ( 25 – 31 ).”
Berger, T., Maršálek, K., Aeckerlein, J., Hauslage, J., Matthiä, D., Przybyla, B., Rohde, M., & Wirtz, M. C. (2019) · Review of Scientific Instruments · doi:10.1063/1.5122301 · Cited by 25 · cited 1×
“The built-in accelerometers enabled the detectors to stay in “sleep-mode” until the moment of launch, thereby conserving battery power ( 42 ).”
Self-citationMatroshka DOSTEL measurements onboard the International Space Station (ISS)
Labrenz, J., Burmeister, S., Berger, T., Heber, B., & Reitz, G. (2015) · Journal of Space Weather and Space Climate · doi:10.1051/swsc/2015039 · Cited by 23 · cited 1×
“…collaboration co-led by the German Aerospace Center (DLR), the Israel Space Agency (ISA), and NASA and supported by StemRad and Lockheed Martin, building upon prior phantom studies in LEO ( 14 – 24 ) and heritage from European Space Agency (ESA) MATROSHKA (MTR) experiments on the ISS ( 25 – 31 ).”
Self-citationMachrafi, R., Garrow, K., Ing, H., et al. (2009) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncp039 · Cited by 22 · cited 1×
“…collaboration co-led by the German Aerospace Center (DLR), the Israel Space Agency (ISA), and NASA and supported by StemRad and Lockheed Martin, building upon prior phantom studies in LEO ( 14 – 24 ) and heritage from European Space Agency (ESA) MATROSHKA (MTR) experiments on the ISS ( 25 – 31 ).”
Berger, T., Hajek, M., Summerer, L., Vana, N., Akatov, Y., Shurshakov, V., & Arkhangelsky, V. (2004) · Advances in Space Research · doi:10.1016/j.asr.2003.08.063 · Cited by 19
Self-citationAppendix B: Interaction Data for Body Tissues
White, D. R., Griffith, R. V., & Wilson, I. (1992) · Reports of the International Commission on Radiation Units and Measurements · doi:10.1093/jicru_os24.1.14 · Cited by 19
Berger, T., Hajek, M., Schoner, W., Fugger, M., Vana, N., Noll, M., Ebner, R., Akatov, Y., Shurshakov, V., & Arkhangelsky, V. V. (2001) · PubMed · Cited by 16
Self-citationArchitectural approach for evaluation of radiation shielding integration in space habitats
Bannova, O., & Gulacsi, E. (2024) · Acta Astronautica · doi:10.1016/j.actaastro.2024.04.022 · Cited by 14 · cited 1×
“While coating an entire spacecraft hull with a meaningful thickness of radiation shielding remains impractical due to mass constraints ( 7 ), concentrating an equivalent thickness of shielding around astronauts’ most radiation-sensitive organs and tissues in the form of a vest incurs a…”
Golubenko, K., Usoskin, I., Rozanov, E., & Bard, E. (2025) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2025.119383 · Cited by 14 · cited 1×
“Concentrations of cosmogenic nuclides found in tree rings and ice cores give evidence of years with integrated fluence exceeding measurements from the space era by one to two orders of magnitude ( 55 – 59 ).”
Berger, T., Hajek, M., Sch ner, W., Fugger, M., Vana, N., Akatov, Y., Shurshakov, V., Arkhangelsky, V., & Kartashov, D. (2002) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a005923 · Cited by 13
Self-citationBaiocco, G., Giraudo, M., Bocchini, L., Barbieri, S., Locantore, I., Brussolo, E., Giacosa, D., Meucci, L., Steffenino, S., Ballario, A., et al. (2020) · Aerotecnica Missili & Spazio · doi:10.1007/s42496-020-00048-0 · Cited by 13 · cited 1×
“…described previously in a StemRad patent (2019, filed in 2016) ( 69 ) and shown to be functionally feasible (but not tested in terms of radiation shielding efficacy) by the Italian Space Agency onboard ISS in November 2017 ( 70 – 72 ), or via additive manufacturing of recycled plastic waste ( 73 ).”
Extreme solar event of AD775: Potential radiation exposure to crews in deep space
Townsend, L. W., Porter, J. A., deWet, W. C., Smith, W. J., McGirl, N. A., Heilbronn, L. H., & Moussa, H. M. (2016) · Acta Astronautica · doi:10.1016/j.actaastro.2016.03.002 · Cited by 12
Li, G., & Lee, M. A. (2019) · The Astrophysical Journal · doi:10.3847/1538-4357/ab0c98 · Cited by 11 · cited 1×
“Although SPEs propagate outward from the Sun, the event-integrated flux becomes nearly isotropic beyond ∼ 1 astronomical unit ( 6 ), indicating that any radiation shielding should maximize solid angle of coverage.”
Validated space radiation exposure predictions from Earth to Mars during Artemis-I
Slaba, T. C., Rahmanian, S., George, S., Laramore, D., Norbury, J. W., Werneth, C. M., & Zeitlin, C. (2025) · npj Microgravity · doi:10.1038/s41526-025-00459-y · Cited by 11 · cited 2×
“5), generated by ray-tracing a manufacturing quality Orion CAD model in HZETRN ( 49 ).”
Self-citationNumerical Study of the Generation of Linear Energy Transfer Spectra for Space Radiation Applications
Badavi, F. F., Wilson, J. W., Abrahms, B. L., & Hunter, A. (2006) · Advances in Space Research · doi:10.1016/j.asr.2010.12.023 · Cited by 11
Farese, A. M., Booth, C., Tudor, G. L., Cui, W., Cohen, E. P., Parker, G. A., Hankey, K. G., & MacVittie, T. J. (2021) · Health Physics · doi:10.1097/hp.0000000000001451 · Cited by 11
Phantom—dosimeter for estimating effective dose onboard International Space Station
Kireeva, S. A., Benghin, V. V., Kolomensky, A. V., & Petrov, V. M. (2007) · Acta Astronautica · doi:10.1016/j.actaastro.2006.09.019 · Cited by 9
The importance of time-resolved personal Dosimetry in space: The ISS Crew Active Dosimeter
Gaza, R., Johnson, A. S., Hayes, B., Campbell-Ricketts, T., Rakkola, J., Abdelmelek, M. F., Zeitlin, C. J., George, S., Stoffle, N., Castro, A., et al. (2023) · Life Sciences in Space Research · doi:10.1016/j.lssr.2023.08.004 · Cited by 7
Self-citationSelective Shielding of Bone Marrow: An Approach to Protecting Humans from External Gamma Radiation
Waterman, G., Kase, K. R., Orion, I., Broisman, A., & Milstein, O. (2017) · Health Physics · doi:10.1097/hp.0000000000000688 · Cited by 6 · cited 2×
“…of radiation shielding through a targeted shielding architecture of a spatially variable thickness that is inversely related to the degree of self-shielding provided by the underlying tissue at each point, a technique first developed for personal wearable gamma radiation shielding on Earth ( 12 ).”
Self-citationSemkova, J., Koleva, R., Todorova, G., Kanchev, N., Petrov, V., Shurshakov, V., Benghin, V., Tchhernykh, I., Akatov, Y., & Redko, V. (2003) · Advances in Space Research · doi:10.1016/s0273-1177(02)00952-3 · Cited by 4
Bone Marrow Harvesting for HCT
Gorin, N. C., Carreras, E., Fernández-Sojo, J., & Villa, J. (2024) · The EBMT Handbook · doi:10.1007/978-3-031-44080-9_15 · Cited by 2
Seedhouse, E. (2024) · Springer eBooks · doi:10.1007/978-3-031-55604-3_5 · Cited by 1
Cited by
Metadata
- Authors
- Houri, J. M., Berger, T., Gaza, R., Hussein, H., Schwarz, S., Waterman, G., Matthiä, D., Marsalek, K., Przybyla, B., Aeckerlein, J., Radenhaeuser, M., Kasemann, M., Coderre, K., Segars, W. P., Samei, E., Kapadia, A. J., Lee, K., Laramore, D., George, S. P., Semones, E., & Milstein, O.
- Affiliations
- StemRad Inc., Tampa, FL, USA.
- Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
- Leidos (United States) (US)
- Lockheed Martin (United States) (US)
- Israel Space Agency (IL)
- German Aerospace Center (DLR), Institute of Aerospace Medicine, Radiation Biology Department, Cologne, Germany.
- Duke University (US)
- Oak Ridge National Laboratory (US)
- The Aerospace Corporation (US)
- National Aeronautics and Space Administration (US)
- Corresponding author
- Houri, Jordan M.
- Milstein, Oren
- ORCID
- Venue
- Science Advances
- Published
- 2026-08-14
- Volume
- 12
- Issue
- 33
- Pages
- eadz1892-eadz1892
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC13464478
- OpenAlex
- W7202264997
- Cited by
- 2
- References
- 60
- Citations by year
- 2026: 2
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Science Advances (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- elib (German Aerospace Center) (submittedVersion)
- Funders
- National Institutes of Health (R01EB001838, P41EB028744)
- National Aeronautics and Space Administration (NNJ15HK11B)
- Deutsches Zentrum für Luft- und Raumfahrt (2475019, 2475075)
- Israel Space Agency (4501432315)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- solar energetic particle events, astronaut radiation exposure, deep space exploration, Artemis I, Orion spacecraft, anthropomorphic phantom, passive dosimeters, radiation belts, effective dose reduction, crewed lunar missions
- MeSH terms
- Wearable Electronic Devices, Cosmic Radiation, Female, Humans, Radiation Protection, Space Flight, Astronauts, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.