An Ion Balance for Ultra-High-Precision Atomic Mass Measurements
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We have developed the analog of a double-pan balance for determining the masses of single molecular ions from the ratio of their two cyclotron frequencies. By confining two different ions on the same magnetron orbit in a Penning trap, we balance out many sources of noise and error (such as fluctuations of the magnetic field). To minimize the systematic error associated with the Coulomb interaction between the two ions, they are kept about 1 millimeter apart from each other, resulting in fractional uncertainty below 1 × 10 –11 . Such precision opens the door to numerous applications of mass spectrometry, including metrology, fundamental physics, and weighing chemical bonds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Mode coupling in a Penning trap:π pulses and a classical avoided crossing
Cornell, E. A., Weisskoff, R. M., Boyce, K. R., & Pritchard, D. E. (1990) · Physical Review A · doi:10.1103/physreva.41.312 · Cited by 181
Self-citationUltrastable superconducting magnet system for a penning trap mass spectrometer
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149649 · Cited by 63
Cited by
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Mopper, K., Stubbins, A., Ritchie, J. D., Bialk, H. M., & Hatcher, P. G. (2007) · Chemical Reviews · doi:10.1021/cr050359b · Cited by 368
Optimized planar Penning traps for quantum-information studies
Goldman, J., & Gabrielse, G. (2010) · Physical Review A · doi:10.1103/physreva.81.052335 · Cited by 44
Verdú, J., Kreim, S., Blaum, K., Kracke, H., Quint, W., Ulmer, S., & Walz, J. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/10/103009 · Cited by 22
Metadata
- Authors
- Rainville, S., Thompson, J. K., & Pritchard, D. E.
- Venue
- Science
- Published
- 2004-01-16
- Volume
- 303
- Issue
- 5656
- Pages
- 334-338
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2062664697
- Cited by
- 133
- References
- 3
- FWCI
- 9.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Ion Balance for Ultra-High-Precision Atomic Mass Measurements. https://app.cochat.ai/papers/10.1126/science.1092320
- The paper
- Rainville, S., Thompson, J. K., & Pritchard, D. E. (2004). An Ion Balance for Ultra-High-Precision Atomic Mass Measurements. Science. https://doi.org/10.1126/science.1092320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.