The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Continuous Particle Separation Through Deterministic Lateral Displacement
Abstract
We report on a microfluidic particle-separation device that makes use of the asymmetric bifurcation of laminar flow around obstacles. A particle chooses its path deterministically on the basis of its size. All particles of a given size follow equivalent migration paths, leading to high resolution. The microspheres of 0.8, 0.9, and 1.0 micrometers that were used to characterize the device were sorted in 40seconds with a resolution of ∼10nanometers, which was better than the time and resolution of conventional flow techniques. Bacterial artificial chromosomes could be separated in 10 minutes with a resolution of ∼12%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion of soluble matter in solvent flowing slowly through a tube
Taylor, G. I. (1953) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1953.0139 · Cited by 5,109
On the dispersion of a solute in a fluid flowing through a tube
Aris, R. (1956) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1956.0065 · Cited by 2,835
Low Reynolds number hydrodynamics: with special applications to particulate media
Happel, J., & Brenner, H. (1983) · Mechanics of fluids and transport processes · doi:10.1007/978-94-009-8352-6 · Cited by 1,354
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Directional motion of brownian particles induced by a periodic asymmetric potential
Rousselet, J., Salome, L., Ajdari, A., & Prostt, J. (1994) · Nature · doi:10.1038/370446a0 · Cited by 634
Bacterial artificial chromosome libraries for mouse sequencing and functional analysis.
Osoegawa, K., Tateno, M., Woon, P. Y., Frengen, E., Mammoser, A. G., Catanese, J. J., Hayashizaki, Y., & de Jong, P. J. (2000) · PubMed · Cited by 298
Sorting by diffusion: An asymmetric obstacle course for continuous molecular separation
Chou, C.-F., Bakajin, O., Turner, S. W. P., Duke, T. A. J., Chan, S. S., Cox, E. C., Craighead, H. G., & Austin, R. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.24.13762 · Cited by 196
Self-citation
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Active Particles in Complex and Crowded Environments
Bechinger, C., Di Leonardo, R., Löwen, H., Reichhardt, C., Volpe, G., & Volpe, G. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.045006 · Cited by 2,961
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Metadata
- Authors
- Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C.
- Venue
- Science
- Published
- 2004-05-14
- Volume
- 304
- Issue
- 5673
- Pages
- 987-990
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1972867200
- Cited by
- 1,634
- References
- 7
- FWCI
- 30.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.