The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A Microfluidic Device for Conducting Gas-Liquid-Solid Hydrogenation Reactions
Abstract
We have developed an efficient system for triphase reactions using a microchannel reactor. Using this system, we conducted hydrogenation reactions that proceeded smoothly to afford the desired products quantitatively within 2 minutes for a variety of substrates. The system could also be applied to deprotection reactions. We could achieve an effective interaction between hydrogen, substrates, and a palladium catalyst using extremely large interfacial areas and the short path required for molecular diffusion in the very narrow channel space. This concept could be extended to other multiphase reactions that use gas-phase reagents such as oxygen and carbon dioxide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Asymmetric Transition Metal-Catalyzed Allylic Alkylations
Trost, B. M., & Vranken, D. L. V. (1996) · Chemical Reviews · doi:10.1021/cr9409804 · Cited by 3,205
Chemistry in Microstructured Reactors
Jähnisch, K., Hessel, V., Löwe, H., & Baerns, M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300577 · Cited by 1,286
Microreactors: New Technology for Modern Chemistry
Ehrfeld, W., Hessel, V., & Löwe, H. (2000) · Wiley eBooks · doi:10.1002/3527601953 · Cited by 778
Micro reactors: principles and applications in organic synthesis
Fletcher, P. D. I., Haswell, S. J., Pombo-Villar, E., Warrington, B. H., Watts, P., Wong, S. Y. F., & Zhang, X. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00432-5 · Cited by 468
Microfabricated Multiphase Packed-Bed Reactors: Characterization of Mass Transfer and Reactions
Losey, M. W., Schmidt, M. A., & Jensen, K. F. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000523f · Cited by 446
Fukuyama, T., Shinmen, M., Nishitani, S., Sato, M., & Ryu, I. (2002) · Organic Letters · doi:10.1021/ol0257732 · Cited by 377
Tokeshi, M., Minagawa, T., Uchiyama, K., Hibara, A., Sato, K., Hisamoto, H., & Kitamori, T. (2002) · Analytical Chemistry · doi:10.1021/ac011111z · Cited by 342
Self-citationDirect fluorination of toluene using elemental fluorine in gas/liquid microreactors
Jähnisch, K., Baerns, M., Hessel, V., Ehrfeld, W., Haverkamp, V., Löwe, H., Wille, C., & Guber, A. (2000) · Journal of Fluorine Chemistry · doi:10.1016/s0022-1139(00)00300-6 · Cited by 301
Design and fabrication of microfluidic devices for multiphase mixing and reaction
Losey, M. W., Jackman, R. J., Firebaugh, S. L., Schmidt, M. A., & Jensen, K. F. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.803416 · Cited by 232
A Novel Polymer-Supported Arene-Ruthenium Complex for Ring-Closing Olefin Metathesis
Akiyama, R., & Kobayashi, S. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020715)41:14<2602::aid-anie2602>3.0.co;2-3 · Cited by 139
Self-citationHydrogenation and Hydrogenolysis
Arnold, M. R. (1956) · Industrial & Engineering Chemistry · doi:10.1021/ie51401a008 · Cited by 9
Cited by
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Continuous‐Flow Technology—A Tool for the Safe Manufacturing of Active Pharmaceutical Ingredients
Gutmann, B., Cantillo, D., & Kappe, C. O. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201409318 · Cited by 1,469
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Metadata
- Authors
- Kobayashi, J., Mori, Y., Okamoto, K., Akiyama, R., Ueno, M., Kitamori, T., & Kobayashi, S.
- Venue
- Science
- Published
- 2004-05-28
- Volume
- 304
- Issue
- 5675
- Pages
- 1305-1308
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1990676461
- Cited by
- 576
- References
- 11
- FWCI
- 32.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.