The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Chemical Detection with a Single-Walled Carbon Nanotube Capacitor
Abstract
We show that the capacitance of single-walled carbon nanotubes (SWNTs) is highly sensitive to a broad class of chemical vapors and that this transduction mechanism can form the basis for a fast, low-power sorption-based chemical sensor. In the presence of a dilute chemical vapor, molecular adsorbates are polarized by the fringing electric fields radiating from the surface of a SWNT electrode, which causes an increase in its capacitance. We use this effect to construct a high-performance chemical sensor by thinly coating the SWNTs with chemoselective materials that provide a large, class-specific gain to the capacitance response. Such SWNT chemicapacitors are fast, highly sensitive, and completely reversible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Carbon Nanotube Sensors for Gas and Organic Vapor Detection
Li, J., Lu, Y., Ye, Q., Cinke, M., Han, J., & Meyyappan, M. (2003) · Nano Letters · doi:10.1021/nl034220x · Cited by 1,810
Qi, P., Vermesh, O., Grecu, M., Javey, A., Wang, Q., Dai, H., Peng, S., & Cho, K. J. (2003) · Nano Letters · doi:10.1021/nl034010k · Cited by 1,012
Array-Based Vapor Sensing Using Chemically Sensitive, Carbon Black−Polymer Resistors
Lonergan, M. C., Severin, E. J., Doleman, B. J., Beaber, S. A., Grubbs, R. H., & Lewis, N. S. (1996) · Chemistry of Materials · doi:10.1021/cm960036j · Cited by 633
Sensors for sub-ppm NO2 gas detection based on carbon nanotube thin films
Valentini, L., Armentano, I., Kenny, J. M., Cantalini, C., Lozzi, L., & Santucci, S. (2003) · Applied Physics Letters · doi:10.1063/1.1545166 · Cited by 502
Carbon Nanotubes in Water: Structural Characteristics and Energetics
Walther, J. H., Jaffe, R., Halicioglu, T., & Koumoutsakos, P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp011344u · Cited by 468
Nerve agent detection using networks of single-walled carbon nanotubes
Novak, J. P., Snow, E. S., Houser, E. J., Park, D., Stepnowski, J. L., & McGill, R. A. (2003) · Applied Physics Letters · doi:10.1063/1.1626265 · Cited by 442
Self-citationThe how and why of electronic noses
Nagle, H. T., Gutierrez-Osuna, R., & Schiffman, S. S. (1998) · IEEE Spectrum · doi:10.1109/6.715180 · Cited by 438
Alcohol Vapor Sensors Based on Single-Walled Carbon Nanotube Field Effect Transistors
Someya, T., Small, J., Kim, P., Nuckolls, C., & Yardley, J. T. (2003) · Nano Letters · doi:10.1021/nl034061h · Cited by 328
High-mobility carbon-nanotube thin-film transistors on a polymeric substrate
Snow, E. S., Campbell, P. M., Ancona, M. G., & Novak, J. P. (2005) · Applied Physics Letters · doi:10.1063/1.1854721 · Cited by 266
Self-citationChemicapacitive microsensors for volatile organic compound detection
Patel, S. V., Mlsna, T. E., Fruhberger, B., Klaassen, E., Cemalovic, S., & Baselt, D. R. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00637-3 · Cited by 203
Highly sensitive and selective sensors based on carbon nanotubes thin films for molecular detection
Valentini, L., Cantalini, C., Armentano, I., Kenny, J. M., Lozzi, L., & Santucci, S. (2004) · Diamond and Related Materials · doi:10.1016/j.diamond.2003.11.011 · Cited by 160
The “NRL-SAWRHINO”: a nose for toxic gases
McGill, R. A., Nguyen, V. K., Chung, R., Shaffer, R. E., DiLella, D. P., Stepnowski, J. L., Mlsna, T., Venezky, D. L., & Dominguez, D. D. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00352-4 · Cited by 83
Cited by
Carbon Nanotubes: Present and Future Commercial Applications
De Volder, M. F. L., Tawfick, S. H., Baughman, R. H., & Hart, A. J. (2013) · Science · doi:10.1126/science.1222453 · Cited by 5,587
Eda, G., Fanchini, G., & Chhowalla, M. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.83 · Cited by 4,379
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Reduced Graphene Oxide Molecular Sensors
Robinson, J. T., Perkins, F. K., Snow, E. S., Wei, Z., & Sheehan, P. E. (2008) · Nano Letters · doi:10.1021/nl8013007 · Cited by 1,772
Self-citationCarbon nanomaterials for electronics, optoelectronics, photovoltaics, and sensing
Jariwala, D., Sangwan, V. K., Lauhon, L. J., Marks, T. J., & Hersam, M. C. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35335k · Cited by 1,284
Metadata
- Authors
- Snow, E. S., Perkins, F. K., Houser, E. J., Badescu, S. C., & Reinecke, T. L.
- Venue
- Science
- Published
- 2005-03-25
- Volume
- 307
- Issue
- 5717
- Pages
- 1942-1945
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2010825644
- Cited by
- 951
- References
- 15
- FWCI
- 62.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.